Manual is about: CCD ZOOM CAMERA, 12V DC

Summary of SZX23-1480 NTSC

  • Page 1

    _____________________________________________________________________ warning: to reduce the risk of fire or electronic shock, do not expose this appliance to rain or moisture and do not remove cover or back. Caution: 1. Connect 12v dc ul listed power supply. 2. Install camera under unstable light s...

  • Page 2

    ______________________________________________________________________ - 1 - www.Okiusa.Com 1. General …… …………………… ……………………… ……… this camera features a new ultra super high sensitive near infra-red ccd sensor and the combination of special optical and digital electronic processing circuit, deliver a...

  • Page 3

    ______________________________________________________________________ - 2 - www.Okiusa.Com dc 12v 3. Major control and their function -- ----------------------- a. Holder screw hole the mounting hole is a standard photographic pan-head screw size (1/4” – 20) b. Dc12v block terminal this terminal ac...

  • Page 4

    ______________________________________________________________________ - 3 - www.Okiusa.Com 4. User osd setting menu and functions ----- --------------- [up] : up & right move key [down] : down & left move key [enter] : enter key [esc] : esc key push [enter] key 3 sec. To get into the osd menu. Push...

  • Page 5

    ______________________________________________________________________ - 4 - www.Okiusa.Com 4.1 camera identification setting (camera id) move cursor to camera id, press enter key to enter id function selecting menu, then press up or down key to select on. Press enter key to enter camera id edit men...

  • Page 6

    ______________________________________________________________________ - 5 - www.Okiusa.Com 4.2 sense up move cursor to sense up, press enter key to enter sense up function selecting menu, then press up or down key to select off, x2, x4, x6, x8, x12, x16, x32 or x64 (0 frame, 2 frames, 4 frames, 6 f...

  • Page 7

    ______________________________________________________________________ - 6 - www.Okiusa.Com 4.3.2aishut fix mode move cursor to aishut, press enter key to enter aishut function selecting menu, then press up or down key to select fix. Press enter key to enter fix level adjustment menu. Page1 main men...

  • Page 8

    ______________________________________________________________________ - 7 - www.Okiusa.Com 4.4.2 aes auto mode move cursor to aes, press enter key to enter aes function selecting menu, then press up or down key to select auto. Press enter key to enter auto level adjustment menu. Page1 main menu pre...

  • Page 9

    ______________________________________________________________________ - 8 - www.Okiusa.Com press enter key to set blc area block. Press up or down key to select blc area block. Opd window this method is suited for cases where the main subject is fixed within the screen. The important object in a sc...

  • Page 10

    ______________________________________________________________________ - 9 - www.Okiusa.Com 4.7 white balance 4.7.1 atw (auto trace white balance) move cursor to white bal, press enter key to enter white bal function selecting menu, then press up or down key to select atw. Press enter key to enter a...

  • Page 11

    ______________________________________________________________________ - 10 - www.Okiusa.Com 4.7.2 awb (auto white balance) move cursor to white bal, press enter key to enter white bal function selecting menu, then press up or down key to select awb. Press enter key to enter awb level adjustment men...

  • Page 12

    ______________________________________________________________________ - 11 - www.Okiusa.Com 4.8 sync this function is used to adjust phase of external sync. When input external sync, we can press enter key to set sync on, then press up or down key to adjust phase. Page 2 main menu 4.9 zoom move cur...

  • Page 13

    ______________________________________________________________________ - 12 - www.Okiusa.Com 4.11 focus move cursor to focus, press enter key to enter focus adjustment menu. Page 2 main menu press up or down key to select focus far to near. Focus adjustment menu 4.12 auto focus move cursor to auto f...

  • Page 14

    ______________________________________________________________________ - 13 - www.Okiusa.Com there have 64 steps (position with zoom & focus) can be programmed. After adjusting position with zoom & focus, press enter key to enter position save selectng menu. Press up or down key to select position (...

  • Page 15

    ______________________________________________________________________ - 14 - www.Okiusa.Com 4.14 h-gain this is used to enhance the compensation of the picture quality. H-gain: horizontal compensation move cursor to h-gain, press enter key to enter h-gain adjustment menu. Press up or down key to se...

  • Page 16

    ______________________________________________________________________ - 15 - www.Okiusa.Com press enter key to enter motion function menu. Press up or down key to select motion detection area, level (sensitivity), time, osd. When detecting motion, it will output alarm signal. Motion menu 4.17 ir ir...

  • Page 17

    ______________________________________________________________________ - 16 - www.Okiusa.Com ir int level table note1: *1: agc level *2: ir int level (act up the level) *3: sense up note2: ir int level (max) approach 15lux (illumination) ir int level (min) approach 0.02lux (illumination) press enter...

  • Page 18

    ______________________________________________________________________ - 17 - www.Okiusa.Com 4.18 initial focus reset function move cursor to initial, press enter key to enter initial on/off menu. Press up or down key to select on/off. Page 3 main menu 4.19 default restart the camera and reset param...

  • Page 19

    ______________________________________________________________________ - 18 - www.Okiusa.Com 4.21 freeze mode freeze field (or frame) of picture function move cursor to freeze mode, press enter key to select freeze mode menu. Press up or down key to select field/frame. Page 4 main menu 4.22 zoom spe...

  • Page 20

    ______________________________________________________________________ - 19 - www.Okiusa.Com 4.24 gamma gamma selection move cursor to set gamma menu, press enter key to select gamma mode , then press up or down key to select gamma1 or gamma2. Gamma1 = 0.45 gamma2 = 1.0 page 4 main menu 4.25 zoom + ...

  • Page 21

    ______________________________________________________________________ - 20 - www.Okiusa.Com 4.27 scale zoom scale display move cursor to scale, press enter key to enter scale on/off menu. Press up or down key to select on/off. The zoom scale will be display on right-down of the screen in scale on m...

  • Page 22

    ______________________________________________________________________ - 21 - www.Okiusa.Com 4.30 misc move cursor to misc, press enter key to enter misc menu. Page 5 main menu 4.30.1 h-revers horizontal reverse (mirror) function move cursor to h-revers, press enter key to enter freeze on/off menu. ...

  • Page 23

    ______________________________________________________________________ - 22 - www.Okiusa.Com 4.30.3 posi/nega positive or negative picture function move cursor to posi/nega, press enter key to enter posi/nega menu. Press up or down key to select posi/nega. Misc menu 4.30.4 priority selecting ir sw i...

  • Page 24

    ______________________________________________________________________ - 23 - www.Okiusa.Com move cursor to h-position, v-position, h-size or v-size press enter key to enter number setting menu. Press up or down key to adjust number (adjusting h-position, v-position, h-size or v-size). Connected set...

  • Page 25

    ______________________________________________________________________ - 24 - www.Okiusa.Com i 03 12 11 10 09 08 07 06 05 04 02 01 f z rs485 do di 5.2 controller the keyboard controller can control most of the camera functions. (reference circuit). Screwless type terminal (remote) pin assignment 01 ...

  • Page 26

    ______________________________________________________________________ - 25 - www.Okiusa.Com 6. Rs-485 control ------------------ ------------------ ** for using rs-485 serial control, camera address id must be set before connecting to the chain system, please refer to 4.31 camera address id setting...

  • Page 27

    ______________________________________________________________________ - 26 - www.Okiusa.Com [70]+preset camera osd key on. * [71]+preset camera id on [72]+preset position osd on [73]+preset zoom scale on [74]+preset sense up on (+4) [75]+preset ais (auto iris on) [76]+preset blc on [77]+preset agc ...

  • Page 28

    ______________________________________________________________________ - 27 - www.Okiusa.Com [1~64]+set set (save) preset point [70]+set camera osd key off [71]+set camera id off [72]+set position osd off [73]+set zoom scale off [74]+set sense up off [75]+set aes (auto iris off) [76]+set blc off [77...

  • Page 29

    ______________________________________________________________________ - 28 - www.Okiusa.Com ** for keyboard not containing “clear” key, following commands cannot be executed. 7. Colour / monochrome auto change ---------------------------------- the camera provides auto change function between color...

  • Page 30

    ______________________________________________________________________ - 29 - www.Okiusa.Com 9.Specifications -------------------- ---------------------------------------- model no. Szx23-1480 szx23-1480p tv system ntsc pal image sensor 1/4-inch super had ccd image sensor picture elements 811(h) x 5...