Pacific Energy ALDERLEA T6 Installation & Operation Manual

Other manuals for ALDERLEA T6: Installation & Operation Manual
Manual is about: ALDERLEA CAST IRON WOOD STOVE

Summary of ALDERLEA T6

  • Page 1

    Keep these instructions for future reference. Installation & operation guide alderlea t6 cast iron wood stove model: alderlea t6 series: b safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or...

  • Page 2: Contents

    Note: we strongly r e c o m m e n d t h at smoke detectors be installed. If smoke detectors have been previ- ously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leaving the fi re door open. Do not disconnec...

  • Page 3: Safety and Maintenance

    3 170314-20 al6b safety and maintenance 1. Burn only dry, well seasoned wood. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood should not be used, as it will reduce heat output, as well as contributing signifi cantl...

  • Page 4: Maintenance Checks

    Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly - brick rail tabs and brick rails. - air...

  • Page 5: Creosote

    5 170314-20 al6b creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosote res...

  • Page 6: Appliance Dimensions

    Fig #1 appliance dimensions outside air opening dimensions 743mm 730mm 216mm 757mm 6 170314-20 al6b if you suspect a chimney fire signs of a chimney fi re may be one or more of the following: 1. A roaring sound 2. Vibration of the chimney 3. Flames and sparks shooting out of the top of the chimney i...

  • Page 7: Installation

    Do not connect this unit to a chimney fl ue serving another appliance. 7 170314-20 al6b installation warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fi red only after the stove is installed properly. Do not attempt to connect this heater...

  • Page 8: Floor Protector

    22" 12" 18" 30" 25" 11" 11" fig #2 single wall connector minimum clearances to combustibles 175mm 250mm 451mm 730mm 150mm 150mm 514mm fig #3 non-combustible fl oor protector [500mm] [875mm] [1124mm] [200mm] [200mm] minimum width - 875mm minimum overall depth - 1124mm minimum thickness - 6mm the stov...

  • Page 9

    Chimney and connector warning: install chimney and all components of chimney system according to chimney manufacturer’s instructions. Connect to a listed chimney complying with the requirements of as/nzs2918/2001 and a chimney suitable for use with solid fuel that is lined and in good condition and ...

  • Page 10

    10 170314-20 al6b firebrick installation instructions this package contains 19 full-size fi rebricks, as well as 5 various cut bricks. With the woodstove in the upright position, install fi rebricks as follows: 1. Place the fi rebricks on the bottom of the unit fi rst. Use a total of 6 full-size (d)...

  • Page 11: Combustion Air

    Intake or combustion air can be supplied to the stove in one of two ways. Consult your local building code before proceeding. 1. Outside air supply - (necessary for mobile home installation, optional for residential installation.) to draw outside air through the fl oor, cut or drill a 102mm diameter...

  • Page 12: Operation

    12 170314-20 al6b operation caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep childre...

  • Page 13

    13 170314-20 al6b how to test your wood add a large piece of wood to the stove when it has a good large bed of coals. It is dry if it is burning on more than one side within one minute. It is damp if it turns black and lights within three minutes. If it sizzles, hisses and blackens without igniting ...

  • Page 14

    14 170314-20 al6b warning: do not use grates or andirons to elevate the fuel. Burn directly on the fi re bricks. Replace broken or missing bricks. Failure to do so may create a hazardous condition. Restarting after extended or overnight burns 1. Open door and rake hot embers towards the front of the...

  • Page 15: Baffle Removal

    15 170314-20 al6b chimney connector pipe should be disconnected from stove to clean and inspect. Only if this is not possible should you remove baffle assembly. Do not operate with baffle assembly or insulation removed. Removal remove retaining pin located at the rear top of the fi rebox, just below...

  • Page 16: Troubleshooting

    16 170314-20 al6b problem cause cure glass is dirty 1. Wood is wet • use dry wood 2. Turning down air control • do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low • improper chimney height and / or diameter, -consult dealer • chimney plu...

  • Page 17: Replacement Parts

    Replacement parts #1 #2 #3 #4 #5 #6 #7 #8 #6 #9 4b 4a 4c 4d 4f 4e 10 11 12 13 14 15 17 #1 baffle kit ....................................... Sumb.Bafkit #2 brick rails (2) ..............................Summ.Railset #3 flame shield ..................................... Sumb.31155 #4 door assembly lef...

  • Page 18

    18 170314-20 al6b.

  • Page 19: Compliance Plate

    19 170314-20 al6b compliance plate 300114 5050.43as model: alderlea t6, summit, summit classic series: c type: freestanding made in canada maximum average heat output burning hardwood - 8.5 kw overall average efficiency burning hardwood - 64% when tested in accordance with as/nzs 4012 pacific energy...

  • Page 20

    Pacific energy fireplace products ltd. Web site: www.Pacifi cenergy.Net 2975 allenby rd., duncan, bc v9l 6v8 printed in canada.