Pacific Energy FP16 Installation And Operating Instructions Manual

Summary of FP16

  • Page 1

    040515-28 fp16 5055.5155 installation and operating instructions safety notice if this fi replace is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about restrictions and installation inspection requi...

  • Page 2: Contents

    2 fp16 040515-28 ©pacific energy fireplace products ltd. Contents safety and maintenance ...................................................................................... 3 maintenance checks ........................................................................................... 4 chimney s...

  • Page 3

    Fp16 040515-28 3 ©pacific energy fireplace products ltd. Safety and maintenance 1. Burn only, dry and well seasoned cord wood. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood should not be used, it will reduce heat...

  • Page 4

    4 fp16 040515-28 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - ...

  • Page 5

    Fp16 040515-28 5 ©pacific energy fireplace products ltd. Chimney smoke and creosote formation when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow bur...

  • Page 6

    6 fp16 040515-28 ©pacific energy fireplace products ltd. Operation caution: hot while in operation. Keep children, clothing and furniture away. Contact will cause skin burns. Warning: over firing the appliance will shorten the life of the product. Failure to rectify an over firing condition can be h...

  • Page 7

    Fp16 040515-28 7 ©pacific energy fireplace products ltd. Disposal of ashes ashes should be placed in a metal container with a tight fi tting lid. The closed container of ashes should be placed outside on a non-combustible fl oor or on the ground, well away from all combustible materials, pending fi ...

  • Page 8

    8 fp16 040515-28 ©pacific energy fireplace products ltd. Baffle removal do not operate with baffle assembly or insulation removed. Warning: after you remove the baffle, always cover the top of the baffle air tube located in the rear of the firebox. This prevents debris falling down the tube. Failure...

  • Page 9

    Fp16 040515-28 9 ©pacific energy fireplace products ltd. Glass cleaning if glass becomes darkened due to poor burning conditions, it can be cleaned with fi replace/ceramic glass cleaner when the fi replace is cold. Never scrape with an object that might scratch the glass. The type and amount of depo...

  • Page 10: Fp16

    10 fp16 040515-28 ©pacific energy fireplace products ltd. Fp16 firebrick installation instructions this package contains 14 full-size fi rebricks. With the heater in the upright position, install fi rebricks as follows: - first, install 4 fi rebricks against the rear wall. - next, install the side f...

  • Page 11

    Fp16 040515-28 11 ©pacific energy fireplace products ltd. Fireplace installation crate removal 1) carefully remove wood top and supports. 2) remove the screws securing the fi replace to the pallet(4). 3) remove from pallet bottom. Warning: under no circumstances is this heater to be installed in a m...

  • Page 12

    12 fp16 040515-28 ©pacific energy fireplace products ltd. Fp16 39" [991mm] 38" 964 4 1/2" 114 28 1/2" 724 18 5/8" 473 22 1/2" 573 dimensions fig. #5 minimum clearances to combustibles 2" 51mm 21 3/8 ” 543mm 30 1/8 " 765mm 2" 51mm 21" 533mm 14" 356mm 5 1/4 " 133mm 2" 51mm fig. #6 standoffs not shown.

  • Page 13

    Fp16 040515-28 13 ©pacific energy fireplace products ltd. 24" 610mm 30 3/8 " 772mm 81" 2.06m 21 1/2 " 546mm 42" 1.07m 55 1/2 " 1.41m 2" 51mm 57 1/4 " 1.45m 57 1/4 " 1.45m 42" 1.07m 42" 1.07m minimum framing dimensions fig. #7 note: framing dimensions around the fireplace are the minimums. Framing di...

  • Page 14

    14 fp16 040515-28 ©pacific energy fireplace products ltd. Item part # description qty. 1 5049.9912 screw, teks pkg #8 x 1/2”(13mm) 40 2 7946 stud, top/bottom 41 3/4”(1.06m)l 2 3 7746.5 stud, cntr support sides, 15”(381mm)l 5 4 7747 framing kit leg 3 1/2"(89mm)l 3 framing kit assembly 2 3 each kit co...

  • Page 15

    Fp16 040515-28 15 ©pacific energy fireplace products ltd. Fig. #8 chimney roof fl ashing storm collar * 4"(102mm) diameter combustion outside air inlet. One on either side of unit. Also one in rear and on bottom of base plate if desired. Spark arrestor rain cap radiation shield chimney support 33" (...

  • Page 16

    16 fp16 040515-28 ©pacific energy fireplace products ltd. Chimney installation listed chimney and chimney connector this appliance must be installed with a 6"(150mm) chimney system approved under the following standards: can-ulc s629(in canada) and ul 103ht(in u.S.). You must follow the chimney manu...

  • Page 17

    Fp16 040515-28 17 ©pacific energy fireplace products ltd. Offsets 30° or 45° elbows the chimney for the fp16 can be installed with a maximum of four 45° elbows(in canada) and four 30° elbows(in u.S.A.) as shown in fig. #10. Installation: 1. Note: install the fi rst elbow and turn it in the required ...

  • Page 18

    18 fp16 040515-28 ©pacific energy fireplace products ltd. Combustion air intake or combustion air can be supplied to the fi replace in one of two ways. Consult your local building code or can/csa-b365, installation code for solid-fuel-burning appliances and equipment before proceeding. 1. Outside ai...

  • Page 19

    Fp16 040515-28 19 ©pacific energy fireplace products ltd. Typical installation the front facing area of the fp16 must be covered with non-combustible cement board prior to applying any non- combustible fi nishing material. Frame the unit in as shown in fig. #13 below using the framing kit provided o...

  • Page 20

    20 fp16 040515-28 ©pacific energy fireplace products ltd. 18" [457mm] 8" [203mm] 8" [203mm] 33 1/2" [851mm] 18" [457mm] 8" [203mm] 8" [203mm] 49 1/2" [1.26m] canada only ember protection the stove may be installed on a combustible fl oor provided ember protection made from a non-combustible material...

  • Page 21: Combustible Mantle

    Fp16 040515-28 21 ©pacific energy fireplace products ltd. 6'(1.83m) floor to ceiling minimum (b) 46 1/2" 1.18m (b) 50 1/2" 1.28m (a)4"(102mm) (a) 12"(305mm) combustible mantle graduated mantle depth (a) height from floor (b) 4"(102mm) 46 1/2"(1.18m) 5"(127mm) 47"(1.19m) 6"(150mm) 47 1/2"(1.21m) 7"(1...

  • Page 22

    22 fp16 040515-28 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - ensure wood is dried to less than 20% moisture content 2. Turning down air control - do not turn air control down until: or damper too soon a) there is a good bed of coals bui...

  • Page 23

    Fp16 040515-28 23 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned fi rewood, up to 18"(46cm) long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (1"(25mm) minimum)). 2. Operate on a medium to high setting, for up to 1 hour from c...

  • Page 24

    24 fp16 040515-28 ©pacific energy fireplace products ltd. Replacement parts item description part no. 1............ Quadrant ..........................................................7953 2............ Blower assembly, lhs ........................... Ne16.7844 .............. Blower only, lhs ..........

  • Page 25

    Fp16 040515-28 25 ©pacific energy fireplace products ltd. Warranty information pacifi c energy limited lifetime warranty wood products pacifi c energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime covera...

  • Page 26

    26 fp16 040515-28 ©pacific energy fireplace products ltd..

  • Page 27: Caution

    Fp16 040515-28 27 ©pacific energy fireplace products ltd. Label le systÈme de cheminÉe doit Être homologuÉ comme suit : au canada - cheminÉe homologuÉe ulc-s-629, aux États-unis - cheminÉ le systÈme de cheminÉe doit Être homologuÉ comme suit : au canada - cheminÉe homologuÉe ulc-s-629, aux États-uni...

  • Page 28

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 for technical support, please contact your retailer. Web site: http://www.Pacifi cenergy.Net printed in canada.