Pacific Energy MIRAGE 30 SERIES A Installation And Operating Instructions Manual

Other manuals for MIRAGE 30 SERIES A: Installation And Operating Instructions Manual

Summary of MIRAGE 30 SERIES A

  • Page 1

    Installer: leave this manual with the appliance. Consumer: retain this manual for future reference. 180516-36 5055.Mr30-a warning: if the information in these instructions is not followed exactly a fire or explosion may result causing property damage, personal injury or death. For your safety do not...

  • Page 2: Table of Contents

    2 5055.Mr30-a 180516-36 table of contents hot glass will cause burns. Do not touch glass until cooled. Never allow children to touch glass. ! Danger a barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed for the protection of c...

  • Page 3: Caution

    3 180516-36 5055.Mr30-a for your safety - do not install or operate your pacific energy gas stove without first reading and understanding this manual. Any installation or oper- ational deviation from the following instructions voids the pacific energy ™ warranty and may prove hazardous. This applian...

  • Page 4

    4 5055.Mr30-a 180516-36 important note for the commonwealth of massachusetts from massachusetts rules and regulations 248 cmr 5.08: (a) for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, inc...

  • Page 5: Mirage 30 Dimensions

    5 180516-36 5055.Mr30-a mirage 30 dimensions center of venting 9 5/16" (237mm) 26 3/8" (670mm) 45 13/16" (1168mm) 27 7/16" (646mm) 40 1/8" (1019mm) 21 3/16" (538mm) figure 1: mirage 30 dimensions..

  • Page 6: Locating The Stove

    6 5055.Mr30-a 180516-36 minimum clearance to combustible materials in planning the installation for the stove, it is necessary to determine where the unit is to be installed, location of vent system or a wall projection (figure 3). Due to high temperatures, do not locate this stove in areas of high ...

  • Page 7: Co-Axial Venting

    7 180516-36 5055.Mr30-a 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 venting horizontal run ve nt in g v er ti ca l ris e no venting option venting envelope mirage 18 / 30 co-axial venting chart no venting option note: the vent must no...

  • Page 8: Co-Linear Venting

    8 5055.Mr30-a 180516-36 1. Measure chimney height, cut fl ex liner (min.10’ to termination) as required. Mark one pipe at both ends to identify combustion air intake pipe from fl ue outlet pipe. 2. Attach marked fl ex liner pipe to the intake side of vent terminal. Seal and secure with sealant and s...

  • Page 9

    9 180516-36 5055.Mr30-a m k i a v g g h a j v g a b c a v v a v b f b l v e v v v d b b air supply inlet vent terminal gas meter fixed closed fixed closed open- able open- able area where terminal is not permitted vent terminal minimum clearances this stove is certified for use with 4” x 6-5/8”co-ax...

  • Page 10: Venting Components

    10 5055.Mr30-a 180516-36 note: mixing venting components from different manufacturers is inadvisable. 4” x 6 5/8” rigid piping components cross reference 4” x 6 5/8” rigid pipe components cross reference chart figure 8: venting components 1. Figure 9: venting components 2. Venting components.

  • Page 11

    11 180516-36 5055.Mr30-a gas and electrical connections gas connection electrical connection plug the provided iec power cord into the receptacle at the rear of the unit as shown in (figure 10). The battery holder and manual “on/remote/off” switch is also located here. See details of operation on pa...

  • Page 12: Gas Supply

    12 5055.Mr30-a 180516-36 servicing of the stove can be performed from the rear of the unit by removing the access panel from the unit. Caution: the gas line should be installed by a qualified service person in accordance with all building codes. This section is intended as a guide for qualified tech...

  • Page 13: Pilot Adjustment

    13 180516-36 5055.Mr30-a note: to test the gas pressure, turn off the gas supply to the stove before loosening test point screws. Verify gas pressures with the stove lit and at the highest setting. 1. Remove switch cover and back panel and locate the valve as seen in (figure 11). 2. Locate the inlet...

  • Page 14: Lighting Instructions

    14 5055.Mr30-a 180516-36 for your safety read before lighting lighting instructions to turn off gas appliance warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignit...

  • Page 15: First Fire

    15 180516-36 5055.Mr30-a first fire when lit for the fi rst time, the gas stove will emit a slight odour for a couple of hours. This is due to the cur- ing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Odo...

  • Page 16

    16 5055.Mr30-a 180516-36 attention! • turn off the main gas supply for the appliance during installation or maintenance of the receiver/module device. • turn off main gas supply for the appliance prior to removing or reinserting the batteries. • in case of remote control malfunction, turn off the fi...

  • Page 17

    17 180516-36 5055.Mr30-a remote transmitter description the proflame 2 remote control consists of two elements: 1. Proflame 2 remote control transmitter. 2. Proflame integrated fireplace control (ifc module) board and a wiring harness to connect the ifc to the gas valve and stepper motor (figure 11)...

  • Page 18

    18 5055.Mr30-a 180516-36 using the remote control transmitter temperature indication display with the remote control transmitter in the “off” position, press the thermostat and mode keys at the same time. Look at the lcd screen on the remote control transmit- ter to verify that a c or f is visible t...

  • Page 19

    19 180516-36 5055.Mr30-a room thermostat (transmitter operation) the remote control transmitter can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room. To activate this function, press the thermostat button (figure 14), the lcd dis...

  • Page 20

    20 5055.Mr30-a 180516-36 continuous pilot/intermittent pilot (cpi/ipi) selection with the system in the “off” position, press the mode key (figure 14) to index to the cpi mode icon (figure 25). Pressing the up arrow key will activate the continuous pilot ignition mode (cpi). Pressing the down arrow ...

  • Page 21: Maintenance

    21 180516-36 5055.Mr30-a caution: turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the gas stove and its venting should be inspected at least once a year by a qualified service person. Glass door: warnin...

  • Page 22: Propane Conversion

    22 5055.Mr30-a 180516-36 propane conversion before starting the conversion make sure to shut off the gas supply to the unit and allow stove to cool to room temperature. To convert the gas stove from natural gas to propane, the (gasc.Lp18kit) kit is required. This kit comes with new pilot and burner ...

  • Page 23: Door Removal / Installation

    23 180516-36 5055.Mr30-a door removal / installation installation 1. Position the glass retainer’s frame so that the studs on unit align with holes in frame. Secure using 12 3/8” nuts (figure 31). Caution: over tightening of nuts could result in glass fracturing. 2. Insert and lower the outer door b...

  • Page 24

    24 5055.Mr30-a 180516-36 note: the burner tray needs to be removed before installation or removal of panels - see (“burner tray installation / removal” on page 25) removal after removing the burner tray, remove the air restrictor plate (figure 36) from the ceiling of the fi rebox. This plate keeps t...

  • Page 25

    25 180516-36 5055.Mr30-a burner kit installation/removal installation interior panels must be installed before burner tray can be installed. The orifi ce must be removed prior to burner tray insertion (figure 41). Remove 2 - 3/8” nuts and extract the orifi ce from the fi rebox. Insert the burner tra...

  • Page 26: Optional Media

    26 5055.Mr30-a 180516-36 optional media 1. Position rear log #1 at the back of the firebox (figure 45). 2. Interlock right log #2 with rear log (figure 46). 3. Lean left log #3 against log set (figure 47). 4. Interlock front log #4 with left log to complete log set structure (figure 48). Note: do no...

  • Page 27

    27 180516-36 5055.Mr30-a cladding removal/installation figure 51: mirage 30 front and side panels. Figure 52: removing mesh screen cover. Figure 53: side panel trim. Trim screws the mirage 30 cladding consists of four panels; the right and left (as seen from the viewer perspective), and an upper and...

  • Page 28

    28 5055.Mr30-a 180516-36 top positioning screw/post for right hand panel. Right hand securing screw for upper front panel right hand securing screw for lower front panel bottom positioning screw/post for right hand panel. Figure 54: upper attach points for side and upper panels. Figure 55: lower att...

  • Page 29: Air Adjustment

    29 180516-36 5055.Mr30-a air adjustment the venturi comes from the factory set to the closed position for use with natural gas. It will need to be adjusted toward the open position for use with propane. To adjust the venturi, the right hand side panel must be removed; see (“cladding removal/installa...

  • Page 30: Replacement Parts

    30 5055.Mr30-a 180516-36 description order number 1. Replacement remote control ....................................... Gasc.Cntrla 2. Replacement control module ...........................................Gasc.Moda 3. Replacement pilot assembly .......................................... Gasc.Pilota ...

  • Page 31: Wiring Diagram

    31 180516-36 5055.Mr30-a caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Wiring diagram lamp comfort fan pilot burner figure 63: electrical diagram for mirage 18..

  • Page 32: Rating Label

    32 5055.Mr30-a 180516-36 rating label a this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimenta...

  • Page 33

    33 180516-36 5055.Mr30-a.

  • Page 34

    34 5055.Mr30-a 180516-36.

  • Page 35

    35 180516-36 5055.Mr30-a.

  • Page 36

    Printed in canada © 2016 copyright pacific energy fireplace products ltd reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer. Web site: www. Pacificenergy.Net 2975 all...