Pacific Energy MIRAGE 30 SERIES A Installation And Operating Instructions Manual

Other manuals for MIRAGE 30 SERIES A: Installation And Operating Instructions Manual

Summary of MIRAGE 30 SERIES A

  • Page 1

    Installer: leave this manual with the appliance. Consumer: retain this manual for future reference. 110915-32 5055.Mr30-a warning: if the information in these instructions is not followed exactly a fire or explosion may result causing property damage, personal injury or death. For your safety do not...

  • Page 2: Table of Contents

    2 5055.Mr30-a 110915-32 table of contents hot glass will cause burns. Do not touch glass until cooled. Never allow children to touch glass. ! Danger a barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed for the protection of c...

  • Page 3: Caution

    3 110915-32 5055.Mr30-a for your safety - do not install or operate your pacific energy gas stove without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the pacific energy ™ warranty and may prove hazardous. This appliance...

  • Page 4

    4 5055.Mr30-a 110915-32 from massachusetts rules and regulations 248 cmr 5.08: (a) for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residen- tial purposes, including those owned or operated by the commonwealth ...

  • Page 5: Mirage 30 Dimensions

    5 110915-32 5055.Mr30-a mirage 30 dimensions center of venting 9 5/16" (237mm) 26 3/8" (670mm) 45 13/16" (1168mm) 27 7/16" (646mm) 40 1/8" (1019mm) 21 3/16" (538mm) figure 1: mirage 30 dimensions..

  • Page 6: Clearances to Combustibles

    6 5055.Mr30-a 110915-32 clearances to combustibles minimum clearance to combustible materials in planning the installation for the stove, it is necessary to determine where the unit is to be installed, location of vent system or a wall projection (figure 3). Due to high temperatures, do not locate t...

  • Page 7: Co-Axial Venting

    7 110915-32 5055.Mr30-a 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 venting horizontal run ve nt in g v er ti ca l ris e no venting option venting envelope mirage 18 / 30 co-axial venting chart no venting option note: the vent must no...

  • Page 8: Co-Linear Venting

    8 5055.Mr30-a 110915-32 1. Measure chimney height, cut fl ex liner (min.10’ to termination) as required. Mark one pipe at both ends to identify combustion air intake pipe from fl ue outlet pipe. 2. Attach marked fl ex liner pipe to the intake side of vent terminal. Seal and secure with sealant and s...

  • Page 9

    9 110915-32 5055.Mr30-a m k i a v g g h a j v g a b c a v v a v b f b l v e v v v d b b air supply inlet vent terminal gas meter fixed closed fixed closed open- able open- able area where terminal is not permitted a= *12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony b=...

  • Page 10: Venting Components

    10 5055.Mr30-a 110915-32 venting components note: mixing venting components from different manufacturers is inadvisable. 4” x 6 5/8” rigid piping components cross reference 4” x 6 5/8” rigid pipe components cross reference chart figure 8: venting components 1. Figure 9: venting components 2..

  • Page 11

    11 110915-32 5055.Mr30-a gas and electrical connections gas connection electrical connection plug the provided iec power cord into the receptacle at the rear of the unit as shown in (figure 10). The battery holder and manual “on/remote/off” switch is also located here. See details of operation on pa...

  • Page 12: Gas Supply

    12 5055.Mr30-a 110915-32 servicing of the stove can be performed from the rear of the unit by removing the access panel from the unit. Caution: the gas line should be installed by a qualified service person in accordance with all building codes. This section is intended as a guide for qualified tech...

  • Page 13: Pilot Adjustment

    13 110915-32 5055.Mr30-a note: to test the gas pressure, turn off the gas supply to the stove before loosening test point screws. Verify gas pressures with the stove lit and at the highest setting. 1. Remove switch cover and back panel and locate the valve as seen in (figure 11). 2. Locate the inlet...

  • Page 14: Lighting Instructions

    14 5055.Mr30-a 110915-32 for your safety read before lighting lighting instructions to turn off gas appliance warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignit...

  • Page 15: First Fire

    15 110915-32 5055.Mr30-a first fire when lit for the fi rst time, the gas stove will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Odour...

  • Page 16

    16 5055.Mr30-a 110915-32 key lock transmission low battery alarm thermostat off/ on/smart room temperature cpi mode set point: temperature/level/state flame on comfort fan attention! • turn off the main gas supply for the appliance during installation or maintenance of the receiver/module device. • ...

  • Page 17

    17 110915-32 5055.Mr30-a remote transmitter description the proflame2 remote control consists of two elements: 1. Proflame2 remote control transmitter. 2. Proflame integrated fireplace control (ifc module) board and a wiring harness to connect the ifc to the gas valve and stepper motor (figure 11). ...

  • Page 18

    18 5055.Mr30-a 110915-32 using the remote control transmitter temperature indication display with the remote control transmitter in the “off” position, press the thermostat and mode keys at the same time. Look at the lcd screen on the remote control transmitter to verify that a c or f is visible to ...

  • Page 19

    19 110915-32 5055.Mr30-a room thermostat (transmitter operation) the remote control transmitter can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room. To activate this function, press the thermostat button (figure 14), the lcd dis...

  • Page 20

    20 5055.Mr30-a 110915-32 continuous pilot/intermittent pilot (cpi/ipi) selection with the system in the “off” position, press the mode key (figure 14) to index to the cpi mode icon (figure 25). Pressing the up arrow key will activate the continuous pilot ignition mode (cpi). Pressing the down arrow ...

  • Page 21: Maintenance

    21 110915-32 5055.Mr30-a caution: turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the gas stove and its venting should be inspected at least once a year by a qualified service person. Glass door: warnin...

  • Page 22: Propane Conversion

    22 5055.Mr30-a 110915-32 propane conversion before starting the conversion make sure to shut off the gas supply to the unit and allow stove to cool to room temperature. To convert the gas stove from natural gas to propane, the (gasc.Lp18kit) kit is required. This kit comes with new pilot and burner ...

  • Page 23: Door Removal / Installation

    23 110915-32 5055.Mr30-a door removal / installation installation 1. Position the glass retainer’s frame so that the studs on unit align with holes in frame. Secure using 12 3/8” nuts (figure 31). Caution: over tightening of nuts could result in glass fracturing. 2. Insert and lower the outer door b...

  • Page 24

    24 5055.Mr30-a 110915-32 firebox panel removal / installation note: the burner tray needs to be removed before installation or removal of panels - see (“burner tray installation / removal” on page 25) removal 1. After removing the burner tray, remove one of the side panel clips (figure 35). Then all...

  • Page 25

    25 110915-32 5055.Mr30-a burner kit installation/removal installation interior panels must be installed before burner tray can be installed. The orifi ce must be removed prior to burner tray insertion (figure 41). Remove 2 - 3/8” nuts and extract the orifi ce from the fi rebox. Insert the burner tra...

  • Page 26: Optional Media

    26 5055.Mr30-a 110915-32 cladding removal/installation optional media 1. Position rear log at the back of the firebox (figure 43). 2. Interlock right log with rear log (figure 44). 3. Lean left log against log set (figure 45). 4. Interlock front log with left log to complete log set structure (figur...

  • Page 27

    27 110915-32 5055.Mr30-a the mirage 30 cladding consists of four panels; the right and left (as seen from the viewer perspective), and an upper and lower panel inset with grills. To remove the panels for service reasons or in order to change to a different set of panels, begin by removing the mesh s...

  • Page 28: Primary Air Adjustment

    28 5055.Mr30-a 110915-32 primary air adjustment to adjust the venturi, the right hand side panel must be removed. To the left of the gas supply hose is a wing nut which can be move to the left or right (figure 57) & (figure 58). Loosening and moving the wing-nut to the left opens the venturi and loo...

  • Page 29: Replacement Parts

    29 110915-32 5055.Mr30-a description order number 1. Replacement control module ...........................................Gasc.Moda 2. Replacement gas valve ................................................ Gasc.Valvea 3. Replacement pilot assembly .......................................... Gasc.Pil...

  • Page 30: Wiring Diagram

    30 5055.Mr30-a 110915-32 caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Wiring diagram lamp comfort fan pilot burner figure 59: electrical diagram for mirage 18..

  • Page 31: Rating Label

    31 110915-32 5055.Mr30-a rating label a this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimenta...

  • Page 32

    Printed in canada © 2015 copyright pacific energy fireplace products ltd reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer. Web site: www. Pacificenergy.Net 2975 all...