Pacific Energy PACIFIC INSERT Installation And Operating Manual

Manual is about: fireplace

Summary of PACIFIC INSERT

  • Page 1

    Tested and listed to ulc s628 / ul 1482 meets the u.S. Environmental protection agency's july 1990 particulate emission standards 010203-16 5055.101 pacinsd1 please save these instructions safety notice if this stove is not properly installed, a house fire may result. For your safety, follow the ins...

  • Page 2: Contents

    2 contents safety ......................................................................................................... 3 clearances ................................................................................................. 3 masonry or factory built fireplace ...............................

  • Page 3

    3 6.5" 24" 20.5" 2" 16" safety read all instructions before installing and using this appliance. We strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove pain...

  • Page 4

    4 installation your insert is designed to be installed into a masonry or factory built zero-clearance fireplace. The masonry fireplace must be built according to the requirements of the standard of chim- neys, fireplaces, vents and solid fuel burning appliances, n.F.P.A. 211 (latest edition) or appl...

  • Page 5

    5 full flue liner - (required in canada) 1) measure the chimney height from the top of the existing flue to the floor of the hearth. This will allow extra length of liner for flashing and rain cap. 2) feed the stainless steel liner from top of the chimney, through the damper area and into the firepl...

  • Page 6

    6 surround assembly and installation 1) lay part a, b and c face down on a flat non-marring surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points “d” (fig. #5 and 8). 2) lift the surround assembly to the upright position and make sure the front face is flat and ev...

  • Page 7

    7 9) push the entire appliance back until the surround assembly is in contact with the fireplace. 10) position the decorative bay stove top onto the firebox top. Ensure that the studs align with the slotted tabs, one on each side of the firebox top. Secure in place with 1/4” nuts provided. 11) repla...

  • Page 8

    8 combustion air consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the insert in one of two ways: 1) outside air supply: remove cover from ash clean out in existing fireplace. Place a rodent screen in place of the cover. Install the insert as d...

  • Page 9

    9 operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods. Wood should be properly air dried (seasoned) for six months ...

  • Page 10

    10 disposal of ashes ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non- combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or ...

  • Page 11

    11 blower the pacific insert comes equipped with a variable speed circulating air blower. The blower system is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Blower operation automatic: to operate the blower automatically, push the rocker switc...

  • Page 12

    12 maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet or unseasoned wood, do so onl...

  • Page 13

    13 1 2 3 4 2 7 2 9 12 13 14 15 16 17 27 19 20 23 25 24 20 6 5 16 17 22 8 10 26 11 18 21a 21b fig. # 18 * standard-size surround assembly, embossed panels 42 3/4" wide x 29" high ** over-size surround assembly, plain panels ... 44 3/8" wide x 33" high 1 ............ Surround side, left (* standard-si...

  • Page 14

    14 understanding & operating your pacific energy stove the pacific energy super series line of woodstoves is a culmination of years of research and development. Designed to be efficient, clean-burn- ing and user-friendly, this heater will give you years of warm service. However, a knowledgeable oper...

  • Page 15

    15 label troubleshooting problem cause cure excessive creosote 1) wood is too wet - use dry wood buildup 2) turning down air control - do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) draft too low - improper chimney height and/or diameter - chimney plugged ...

  • Page 16

    Pacific energy fireplace products ltd. Box 1060, duncan, b.C. V9l 3y2 phone: (250) 748-1184 web site: http://www.Pacificenergy.Net printed in canada 16.