Tested and listed to can/ulc s627 and ul 1482 meets the environmental protection agency’s july 1990 particulate emission standards please save these instructions installation & operation guide alderlea cast iron wood stove models t4, t5, t6 safety notice if this stove is not properly installed, a ho...
Safety and maintenance .....................................................................................3 creosote .......................................................................................................................4 formation and need for removal ................................
3 261107-28 t4-5-6 safety and maintenance 1. Burn only dry and well seasoned wood. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet or ...
4 261107-28 t4-5-6 creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosote r...
We recommend that our woodburning hearth products be installed and serviced by professionals who are certifi ed in the u.S. By the national fireplace institute ® (nfi) as nfi woodburning specialists or who are certifi ed in canada by wood energy technical training (wett). 5 261107-28 t4-5-6 6. Prepa...
Fig #1 appliance dimensions model t4 model t5 model t6 26” 20.75” 5.75” 28” 25” 28.5” 10.125” 29.11/16” 29.25” 28.75” 8.5” 29.13/16” 6 261107-28 t4-5-6.
22" 12" 18" 30" 25" 11" 11" 20" 16" 26" 14" 15" 5" 10" 16" 18" 28" 4" 4" fig #2 single wall connector double wall connector alcove: min. Height 7 1/2 feet max. Depth 4 feet fig #2a 15” 14” 20.75” 26” 7” 12” 12.75” 24” 10” 10” 22.625” 3” 3” 15.625” 11” 12” 12” 16.75” 24” minimum clearances to combust...
22" 12" 18" 30" 25" 11" 11" 20" 16" 26" 14" 15" 5" 10" 16" 18" 28" 4" 4" fig #2d single wall connector double wall connector alcove: min. Height 7 1/2 feet max. Depth 4 feet fig #2e minimum clearances to combustibles – residential 22" 12" 18" 30" 25" 11" 11" 20" 16" 26" 14" 15" 5" 10" 16" 18" 28" 4"...
Fig #3 chimney and connector – residential connect to a listed chimney or a chimney suitable for use with solid fuel that is lined and in good condition and meets local building codes. The chimney fl ue size should be the same as the stove outlet for optimal performance. Reducing or increasing the f...
Double-wall connector – residential • use a listed double-wall connector suitable for solid fuel. • install all components to the chimney connector manufacturer's installation require- ments. Single-wall connector – residential smoke pipe must be: • as short and straight as possible, use six inch di...
Caution: the structural integrity of the mobile home fl oor, wall, and ceiling/roof must be maintained. 8" 28" 18" 16" 8" 22" 8" fig #4a double wall connector minimum clearances to combustibles – mobile home 12” 20.625” 12” 17.75” 24” model t4 warning: under no circumstances is this heater to be ins...
Model t5 8" 28" 18" 16" 8" 22" 8" fig #4c double wall connector minimum clearances to combustibles – mobile home 7” 19.75” 14” 15.5” 26.75” 5” 5” model t6 8" 28" 18" 16" 8" 22" 8" fig #4b double wall connector minimum clearances to combustibles – mobile home 12 261107-28 t4-5-6.
Installation procedure – mobile home caution: the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. Note: see "combustion air" section on page 14 1. Position stove and fl oor protection with hole for combustion air in accordance with the clearances as stated on...
Fig #5 fig #6 non-combustible fl oor protector non-combustible fl oor protector 16" [406mm] 8" [203mm] 8" [203mm] u.S.A. Only 8" [203mm] 18" [457mm] 8" [203mm] 8" [203mm] canada only minimum width t4 - 40” t5 - 40” t6 - 41 1/2” minimum overall depth t4 - 43 1/4” t5 - 50 1/2” t6 - 50 1/2 minimum widt...
15 261107-28 t4-5-6 operation caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep child...
16 261107-28 t4-5-6 lighting for the first time curing of the paint finish to achieve the best fi nish, the paint on your stove must be baked on. When burning your stove for the fi rst 2-3 times it is very important that the room be well ventilated. Open all windows and doors. Smoke and fumes caused...
17 261107-28 t4-5-6 restarting after extended or overnight burns 1. Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of embers, close door. 2. Adjust air control to high (left position) and in just a few minutes, logs should begin burning. 3. Afte...
18 261107-28 t4-5-6 chimney connector pipe should be disconnected from stove to clean and inspect. Only if this is not possible should you remove baffl e assembly. Do not operate with baffle assembly or insulation re- moved. Removal remove retaining pin located at the rear top of the fi rebox, just ...
19 261107-28 t4-5-6 problem cause cure glass is dirty 1. Wood is wet • use dry wood 2. Turning down air control • do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low • improper chimney height and / or diameter, consult dealer • chimney pl...
#1 #2 #3 #4 #5 #6 #7 #8 #6 #9 1b 1a 1c 1d 4b 4a 4c 4d 4f 4e 5b 5a 5c 7b 7a 10 11 12 13 14 16 15 17 7c 20 19 18 21 #1 baffle kit 1a ...Baffle 1b ...Side insulation 1c ....Baffle pin 1d ...Baffle gasket #2 brick rails #3 flame shield #4 door assembly 4a ...Door handle 4b ...Door casting mbk 4c ....Hin...
#5 firebrick set 5a ...Firebrick - 1 1/2” x 4 1/2” x 1 1/4” (1) 5b ...Firebrick - 4” x 4 1/2” x 1 1/4” (1) 5c ....Firebrick - 7 1/4” x 4 1/2” x 1 1/4” (1) 5d ...Firebrick - 9” x 4 1/2” x 1 1/4” (16) #1 baffle kit 1a ...Baffle 1b ...Side insulation 1c ....Baffle pin 1d ...Baffle gasket #2 brick rails...
#1 baffle kit ......................................................................... Summ.Bafkit #2 brick rails (2) ............................................................... Summ.Railset #3 flame shield ........................................................................ Summ.3155 #4 do...
23 261107-28 t4-5-6 t4 firebrick installation instructions t5 firebrick installation instructions t6 firebrick installation instructions this package contains 18 full-size fi rebricks, as well as 3 various cut bricks. With the woodstove in the upright position, install fi rebricks as follows: 1. Pla...
24 261107-28 t4-5-6 label t4 certified for canada and u.S.A. Listed room heater, solid fuel type. Also for use in mobile homes tested to can/ulc s627-m93 and ul 1482-98 report no. 6680 (aug. 89) series: c model: vista classic • do not connect this unit to a chimney flue serving another appliance (us...
25 261107-28 t4-5-6 label t5 1482-98 certified for canada and u.S.A. Listed room heater, solid fuel type. Also for use in mobile homes tested to can/ulc s627-m93 and ul model series d: super 27 spectrum classic 130307 5050.75 sup1-a2 a. Sidewall to unit 18 in. / 455 mm 14 in. / 355 mm 14 in. / 355 m...
26 261107-28 t4-5-6 label t6 certified for canada and u.S.A. Listed room heater, solid fuel type. Also for use in mobile homes tested to ulc s627-m93 and ul 1482-1998 series: a model: pacific summit • install and use in accordance with the manufacturer's installation and operating instructions. • co...
27 261107-28 t4-5-6 notes.
Pacific energy fireplace products ltd. Phone: 1-888-715-2398 web site: www.Pacifi cenergy.Net 2975 allenby rd., duncan, bc v9l 6v8 printed in canada.