Pacific Energy T5 Installation & Operation Manual - Label T6
26
261107-28 T4-5-6
Label T6
CERTIFIED FOR CANADA AND U.S.A.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES
TESTED TO ULC S627-M93 AND UL 1482-1998
SERIES:
A
MODEL:
PACIFIC SUMMIT
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN
YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• CONNECT TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS-18INCHES/
455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER
MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
* AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
COMBUSTIBLE ALCOVE SIZE : DEPTH - 4 FT. / 1.22 M MAXIMUM, HEIGHT 7 FT. / 2.1 M MINIMUM
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EXTENDED TO THE
FRONT, SIDES AND BACK AS INDICATED.
A. SIDEWALL TO UNIT
12 in. / 305 mm
12 in. / 305 mm
12 in. / 305 mm
12 in. / 305 mm 15 in. / 381 mm
14 in. / 355 mm
B. BACKWALL TO UNIT
9 in. / 229 mm
10 in. / 254 mm
6 in. / 152 mm 10 in. / 254 mm
9 in. / 229 mm
7 in. / 178 mm
C. CORNER TO UNIT
4 in. / 102 mm
4 in. / 102 mm
4 in. / 102 mm
4 in. / 102 mm
N/A
5 in. / 127 mm
D. SIDEWALL TO CONNECTOR * 21.8 in. / 554 mm 21.8 in. / 554 mm 21.3 in. / 541 mm 21.3 in. / 541 mm 24.3 in. / 617 mm 23.3 in. / 592 mm
E. BACKWALL TO CONNECTOR * 14.5 in. / 368 mm * 15.5 in. / 394 mm * 11 in. / 279 mm * 15.5 in. / 394 mm * 14 in. / 355 mm * 12 in. / 305 mm
F. CORNER TO CONNECTOR
* 15.8 in. / 401 mm * 15.8 in. / 401 mm * 15.3 in. / 389 mm * 15.3 in. / 389 mm
N/A * 16.3 in. / 414 mm
DO NOT REMOVE THIS LABEL
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
• COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT, AND ONE OF THE
FOLLOWING LISTED CONNECTORS: SECURITY MODELS DP OR DC, OLIVER MACLEOD MODEL PV, ENERGY VENT
MODEL E VENT, SELKIRK METALBESTOS MODEL DS, METAL FAB MODEL DW, AMERI-TEC MODEL DBSP, INDUS-
TRIAL CHIMNEY MODEL EXCEL ULTRA-BLACK, OR SIMPSON DURA-VENT MODEL DVL IN COMBINATION WITH ONE
OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS: APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG
KIT ATTACHED.
IN CANADA - SECURITY MODEL S2100, OLIVER MACLEOD PROJET MODEL HT 3000, SELKIRK SENTINEL MODEL CF,
INDUSTRIAL CHIMNEY MODEL EXCEL 2100, ENERGY VENT COMMANDER 5000.
IN USA - SECURITY MODEL ASHT OR S2100, OLIVER MACLEOD MODEL 3103 OR HT 3000, SELKIRK METALBESTOS
MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP-
SON DURA-VENT MODEL DURA/PLUS AND DURA TECH.
USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• OPTIONAL COMPONENTS - FAN KIT #SSER.BLOW, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS., FRESH AIR KIT
DO NOT ROUTE POWER CORD BENEATH HEATER.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
MADE IN CANADA
2004 2005 2006 2007 2008
2009
J F M A M J J A S O N D
DATE OF MANUFACTURE
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 3Y2
SUMM-A1
VERTICAL CONNECTOR HORIZONTAL CONNECTOR
RESIDENTIAL CLOSE CLEARANCE
INSTALLATION
USING DOUBLE WALL CONNECTOR
VERTICAL CONNECTOR HORIZONTAL CONNECTOR
ALCOVE
INSTALLATION
USING
DOUBLE WALL
CONNECTOR
MOBILE HOME
INSTALLATION
USING
DOUBLE WALL
CONNECTOR
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
U.S. ENVIRONMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH
JULY, 1990, PARTICULATE
EMISSION STANDARDS
WH-
CAUTION
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR
IN CANADA G.
18 INCHES / 455 MM
H.
8 INCHES / 200 MM
I.
8 INCHES / 200 MM
IN U.S.A.
G.
16 INCHES / 405 MM
H.
5 INCHES / 127 MM
I.
0 INCHES / 0 MM
REPORT NO. 476-1491-00 (MAR 98)
130307
5050.76
C
F
ADJACENT WALL
E
B
A
SIDE WALL
D
H
SIDE
FRONT
H
SIDE
G
BACK I
HEATER
BACK WALL
ADJACENT WALL
ALDERLEA T6