Pacific Energy VISTA CLASSIC Installation And Operating Instructions Manual - Minimum
8
201213-20
Clearances may be reduced with various heat insulating
materials. Consult local fi re codes and authorities for
approval.
Chimney and Chimney Connector
This heater must be installed with double wall connector
and compatible chimney system.
NOTE: Longer chimney lengths and different pitch fl ashings
may be used. All other parts listed must be installed (see
Figure #2, Page 6). Install all components to the connec-
tor or chimney manufacturer's installation requirements.
Consult your chimney supplier for installation advice.
Procedure
Note: See "Combustion Air" section on page 8.
1. Position stove and fl oor protection with the clearances
as stated on the label or as in Figure #1a and 1b, page
4 & 5.
2. Mark the position for the hole in the ceiling and roof
by using a string and plumb-bob.
3. Check that the intended location will not interfere with
fl oor joists, ceiling joists or rafters before proceeding
further.
4. Cut a hole in the ceiling and roof to suit the chimney
system and frame in the sides. The chimney support
is mounted to the framing.
5. Assemble chimney sections (twist locks) so the fi nished
length is resting on support and protruding through
the roof. Avoid having joints between ceiling and roof.
Install radiation shield. Assemble fl ashing and storm
collar and be sure to maintain the vapour barrier at
this point. (Seal securely) Attach rain cap and check
fl ashing for leaks.
6. Install connector as per manufacturer's instructions.
7. Attach stove to fl ooring using two 1/4" x 2" or longer
lag screws.
Mobile Home
Installation
Warning: Under no circumstances is this heater to
be installed in a makeshift or "temporary" manner. It
may be fi red only after the following conditions have
been met.
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
•
DO NOT INSTALL IN SLEEPING ROOM
•
Outside air supply must be used for Mobile
Home installations (see Fig. #2, Page 6)
•
The services of a competent or certifi ed in-
staller, certifi ed by the Wood Energy Technical Train-
ing program (WETT) - in Canada, Hearth Education
Foundation (HEARTH) - in U.S.A., are strongly recom-
mended.
CAUTION: THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR , WALL AND CEILING/ROOF
MUST BE MAINTAINED.
Clearances
This heater must be installed with listed double wall con-
nector and compatible chimney system.
Pacifi c Vista and Vista Classic: Clearances to com-
bustible surfaces and materials are shown in Figure
#1a, page 4.
12"
12"
17 3/4"
24"
8"
20 5/8"
8"
3"
3"
15 5/8"
11"
24"
12"
12"
16 3/4"
12"
12 3/4"
24"
7"
14"
15"
20 3/4"
26"
10"
10"
22 5/8"
Single Wall Connector - Residential
Alcove height - 7' min.
Alcove depth - 3' max.
Double Wall Connector - Mobile Home
Double Wall Connector - Residential
Minimum
Clearance to
Combustibles
FIG. #3