Pacific Hydrostar 95618 Set Up And Operating Instructions Manual - Operation
SKU 95618 For technical questions please call 1-800-444-3353 Page 11
Operation
Pick up the Spray Gun (43) and point it in a safe direction. Squeeze the
1.
Spray Gun Trigger until all internal air is released, and a steady flow of water
comes out. Then release the Spray Trigger.
Turn the Fuel Valve (D) to the open position (see engine photo below).
2.
Turn the Speed Control Lever (C) all the way to the left, or fast position (see
3.
photo below).
4. Move the Choke Lever (B) all the way to the left, or closed position (see photo
above).
Pull the Starting Handle (A) (shown above in photo) lightly until you feel
5.
resistance. Then, pull it completely out. The engine should start up. If the en-
gine does not start after a few tries, refer to Engine Manufacturer’s Trouble-
shooting Tips. Slowly release the Starting Handle.
Adjust the Speed Control Lever (C) for the desired speed and subsequent
6.
output water pressure. Open the Choke Lever (B) to the right.
Hold the Spray Gun (43) with both hands and begin spraying. Do not allow
7.
the engine to run for more than three minutes without spraying.
Turning Off the Pressure Washer
Turn the Speed Control Lever (C) to the right, or stop position. The engine will
1.
stop.
Turn the Fuel Valve (D) up to the left, or closed position (see photo page 9).
2.
07d