Pahlen 14983311 User Manual - Heat Pump Pvp Inverter
4
Heat pump PVP Inverter
MA20-14E rev 1
ENGLISH
Technical parameters
PVP10
Item no. 14983311
PVP11
Item no. 14983314
PVP13
Item no. 14983315
PVP17
Item no. 14983316
PVP28
Item no. 14983318
Heat power
in “Smart” operation mode
A 2.4–9.8kW*
2.8–11.3kW*
3.4–13.3kW*
4.4–17.3kW*
7.0–27.5kW*
B 1.7–6.5kW*
1.9–7.3kW*
2.3–9.4kW*
2.8–11.4kW*
4.5–18.0kW*
Heat power
in “Silence” operation mode
A 2.4–7.8kW*
2.8–9.0kW*
3.4–10.4kW*
4.4–13.8kW*
7.0–21.7kW*
B 1.7–5.1kW*
1.9–5.8kW*
2.3–7.4kW*
2.8–8.8kW*
4.5–14.5kW*
C.O.P.
in “Smart” operation mode
A 6.4–15.0*
6.5–15.1*
6.4–15.0*
6.3–15.2*
6.2–15.2*
B 4.4–7.6*
4.5–7.7*
4.4–7.6*
4.3–7.8*
4.3–7.8*
C.O.P.
in “Silence” operation mode
A 7.4–15.0*
7.5–15.1*
7.4–15.0*
7.3–15.2*
7.2–15.2*
В 5.1–7.6*
5.2–7.7*
5.1–7.6*
5.2–7.8*
5.0–7.8*
Rated power
0.2–1.4kW
0.22–1.6kW
0.25–2.1kW
0.33–2.6kW
0.58–4.0kW
Rated operation current
0.86–6.4A
0.95–7.4A
1.1–9.1A
1.4–10.9A
0.8–5.8A
Electric connections
230V/1-phase/50Hz
400V/3-phase 50Hz
Recommended water flow
3–4m³/h
4–6m³/h
5–7m³/h
6.5–8.5m³/h
10–12m³/h
Pipeline water in and out
Ø50mm
Weight
49 kg
50 kg
52 kg
63 kg
90 kg
Refrigerant
R410A
Refrigerant quantity
0.85 kg
1.0 kg
1.1 kg
1.25 kg
2.6 kg
Recommended pool volume
20–40m³
25–50m³
30–60m³
40–75m³
60–120m³
A (Ambient conditions А) = Air +26°С, Water +26°С, Humidity 80%.
B (Ambient conditions В) = Air +15°С, Water +26°С, Humidity 70%.
* Data is provided for optimal conditions.
Note!
We reserve the right to change the specifications without prior notice.
Please note that the heat pump funkctions and parameters vary depending on the circumstances. See the rating plate on the
pump for details.
Safety
•
Make sure that the main power switch is located out of reach of children.
•
Never remove the protection in front of the fan.
•
Never put your hands in the air outlet.
•
Turn off the heat pump during lightning storms in order to prevent damage.
•
Do not place near the heat pump any objects that can block airflow.
•
Never use/store flammable gaseous or liquid substances (e.g. paint thinner, paint, fuel ) near the heat pump.
•
Never attempt to repair the heat pump. In case of an unusual noise, smell, smoke or electric faults - immediately switch off the
machine power and contact your installer.
•
If the pump has not been used for a long time: switch the power off and drain the heat pump from water. Cover it.
Transporting
Transport the heat pump standing safely in its original packaging.
The heat pump should NOT be lifted with pipe connections since the titanium heat exchanger inside the heat pump can be dam-
aged.
Pahlén is not responsible for any damage caused by improper handling.