Pahlen 14983311 User Manual - Heat Pump Pvp Inverter
5
300
800
300
300
30
0
F
C
B
H
A
D
E
M12400-0
G
30
0-
40
0
2500
Heat pump PVP Inverter
MA20-14E rev 1
ENGLISH
Dimensions
A
B
C
D
E
F
G
H
Item no. 14983311 Heat pump PVP10
315
590
312
340
961
340
74
658
Item no. 14983314 Heat pump PVP11
315
590
312
340
961
340
74
658
Item no. 14983315 Heat pump PVP13
315
590
312
340
961
340
74
658
Item no. 14983316 Heat pump PVP17
395
590
392
420
961
390
74
658
Item no. 14983318 Heat pump PVP28
395
590
392
420
1092
620
74
958
Installation
Water flow through the heat pump is driven by the external pool circulation pump. The recommended water flow is shown in the
technical specification.
Placing
Placing of the heat pump is very important and can affect its performance and maintenance options.
Consider the following factors:
•
Heat pump must be installed outdoors in a well-ventilated place in order to avoid cold air recirculation.
It requires at least 300 mm clearance from the walls, shrubbery or the like around the heat pump in order not to block air intake.
Note also that the pump requires at least 2500 mm space in front of it in order to prevent air recirculation.
We do NOT recommend placing the pump under the eaves, wooden decks or porches, since this may cause cool air
recirculation that can greatly affect performance.
•
Consider that it should be easy to access around the heat pump at installation (plumbing and electric works), and that enough
space is also available for future maintenance .
•
The total length of pipe between the heat pump and the pool should not exceed 10 meters. Heat pump must ALWAYS be
connected with a fixed tube.
•
It should be placed on a firm, level surface, on a 300-400 mm high concrete base or a tripod that can handle its weight.
Fix the heat pump frame/feet with M10 bolts.
•
Heat pump should never be placed near any source of explosive or corrosive substances.
•
In order to protect the heat pump in exposed locations, prevent sand or air with high salt content (since this can cause clogs,
damage or corrosion to the pump), you can plant shrubs or put up fences for protection, but at a good distance from the
heat pump.
•
When the heat pump is working, condensation water is formed in the bottom. Make sure that the supplied drainage hose for
water drainage has been installed.
Required free space = min. measured in mm