TECHNICAL DATA
Burner Dimensions
Burner Specifications
Minimum Clearances to Combustible Materials:
MODEL #
MAX INPUT
Btu/Hr
INLET
PRESSURE MIN
INLET
PRESSURE MAX
MANIFOLD
PRESSURE
ORIFICE SIZE
BURNER PORTS
PORT SIZE
LIN-36
60,000
4.5” W.C.
10.5” W.C.
3.5” W.C.
26
35
1/8”
LIN-48
80,000
4.5” W.C.
10.5” W.C.
3.5” W.C.
18
47
1/8”
LIN-36P
57,000
11.0” W.C.
13.0” W.C.
10.0” W.C.
43
35
1/8”
LIN-48P
77,000
11.0” W.C.
13.0” W.C.
10.0” W.C.
37
47
1/8”
ELECTRICAL (ALL MODELS)
120V 15A OUTDOOR RECEPTACLE - DEDICATED CIRCUIT WITH WALL SWITCH. BURNER CONNECTS VIA AN AC ADAPTER.
MUST BE INSTALLED AND GROUNDED IN ACCORDANCE WITH LOCAL CODES
ABOVE
LONG SIDE
SHORT SIDE
BELOW
72”
8”
16”
0”
48” (LIN-48), 36” (LIN-36)
10”
9”
8”