Panamax M7500-PRO Owner's Manual

Other manuals for M7500-PRO: Specifications
Manual is about: Manual

Summary of M7500-PRO

  • Page 1

    Owner’s manual m7500-pro power filtration and regulation active high current ground isolation active bank 1 on bank 2 o n bank 3 on bank 4 on bank 5 bank 5 hc 1 on hc 2 on brightness press: meter select home theater power manageme nt auto 1690 corporate circle, petaluma ca 94954 • www.Panamax.Com mo...

  • Page 2: Table of Contents

    1 - max ® 7500-pro 1 - rj-11 telephone cable 2 - coax cables for satellite tv, cable tv, and/or antennas 2 - rack ears w/ screws for rack mounting option important safety instructions......................................1 introduction....................................................................

  • Page 3: Max

    1 © 2007 panamax, inc. All rights reserved. Panamax, the panamax logo and max are registered us trademarks of panamax. Acregenerator, firewall for noise, protect or disconnect and signalperfect are trademarks of panamax. Sidactor is a registered us trademark of teccor electronics, inc. Tivo is a tra...

  • Page 4: Introduction

    2 your audio/video components are constantly being bombarded by electromagnetic interfer- ence (emi) and radio frequency interference (rfi) through their power cords. This contam- inated power can affect analog and digital equipment and will degrade the overall per- formance of your entire system. D...

  • Page 5: Connection Diagram

    3 connection diagram bank 1 always on bank 2 switched bank 3 switched bank 4 switched bank 5 high current ground lug 15 amp circuit breaker main power 120vac/15a hc 1 switched hc 2 switched circuit breaker banks 3 and 4 phone line to equip 2 phone line to equip 1 phone line in lan line in lan to equ...

  • Page 6: Feature Overview

    4 bank 1 always on bank 2 switched bank 3 switched bank 4 switched bank 5 high current ground lug 15 amp circuit breaker main power 120vac/15a hc 1 switched hc 2 switched circuit breaker banks 3 and 4 phone line to equip 2 phone line to equip 1 phone line in lan line in lan to equip usb light input ...

  • Page 7: Feature Details

    5 feature details power switch and led indicator: momentary pushbutton (non-latching); activates a turn-on or turn-off sequence for all the outlet banks. Press and hold the button for 2 seconds to initiate a turn-on or turn-off sequence. Meters: the analog meters are backlit to provide the ability t...

  • Page 8: Feature Details

    6 in the custom settings mode all of the outlet delays as well as the trigger sources for each individ- ual bank operate from the configuration that has been programmed into the eeprom of the unit through the communication interface on the rear panel. Refer to the section titled “max pro series comm...

  • Page 9: Feature Details

    7 phone line to equip 2 phone line to equip 1 phone line in lan line in lan to equip usb light output 12v/400ma bank 2 bank 3 bank 4 5 hc 1 5 hc 2 switch settings custom settings delay always on delay always on delay always on delay always on delay always on 5vdc/100ma trigger universal coax protect...

  • Page 10: Technical Specifications

    8 technical specifications design and specifications subject to change without notice due to product improvement. Fuseless/auto-resetting...................................................................................Yes clamping level.................................................................

  • Page 11

    9 max pro-series communication/configuration specifications 1. Overview the m7500-pro has a rs232 interface that allows it to communicate with a wide variety of equipment as well as enable custom operating configurations to be programmed into the unit. The purpose of this document is to outline the ...

  • Page 12

    10 max pro-series communication/configuration specifications (continued) sets the voltmeter, ammeter and led brightness to x% assigns the trigger(s) for an outlet bank or dc trigger output. These trigger set- tings are only used with the unit isset in custom setting mode. See page 4 for more informa...

  • Page 13

    11 max pro-series communication/configuration specifications (continued) sets the feedback to on (unsolicited) or off (polled). When on, a message will be sent to the controller every time the status of an input (i.E. Trigger), output (i.E. Outlet) or power state (i.E. Overvoltage) changes. If feedb...

  • Page 14

    12 max pro-series communication/configuration specifications (continued) ?Id ?Trigstat ?Outletstat ?Powerstat ?Voltage ?Current ?Help request that the unit identify itself. Request the on/off status of the front panel button and input trigger. Request the on/off status of the outlet banks and output...

  • Page 15

    13 max pro-series communication/configuration specifications (continued) request a list of all configurable parameters and current settings. 2.8 ?List_config $trigger for 1 = triggersource $trigger for 2 = triggersource $trigger for 3 =triggersource $trigger for 4 = triggersource $trigger for hc1 = ...

  • Page 16: Troubleshooting

    14 max pro-series communication/configuration specifications (continued) input voltage falls below the undervoltage threshold. Input voltage falls within safe operating range following an over-voltage or under-voltage condition. Upon leaving the recovery mode following an over-voltage or under-volta...

  • Page 17

    It is the policy of panamax that it will, at its election, either replace, pay to replace at fair market value, or pay to repair, up to the dollar amount specified below, equipment that is damaged by an ac power, cable, telephone, or lightning surge while connected to a prop- erly installed panamax ...