5) Deice control
• Deicing operation is controlled by sensing the indoor piping
temperature and timer.
• Deicing starts when 60 minutes after start of heating or deice
ends and if the indoor piping temperature is 46
°
(
°
C) or lower.
• Deicing ends by function of the pressure switch or after 9
minutes of deice operation.
6) Airflow direction control
1
Manual operation
When the airflow direction adjustment button of the remote
control is pressed, the louver moves up/down in the movable
range shown in the diagram at right, and can be stopped at the
required position.
Only the up/down louvers are adjustable from the remote control.
2
Automatic airflow direction
1) For cooling and soft dry
The up/down louver swings within the movable range.
2) For heating
As shown in the diagram at left, the blow out angle changes
according to the blow out temperature.
* Angle of the left/right louver is manually adjusted.
7) Automatic Operation
When
s
(automatic operation) is set with the “operation mode
selector” on the remote control, the indoor fan runs at Low speed
for 20sec., the air conditioner unit senses the room temperature
then automatically selects the operation mode and temperature
setting.
Intake
Temp. (
°
C)
[
25
21
Operation mode
Cooling
Soft Dry
Heating
Setting Temp
(standard)
27
24
22
1
Relationship between room temperature at start and operation
mode:
* Operation lamp flashes while fan is running for the first
20sec., then lights.
* At start of operation, if the room temperature is 16
°
C or
lower, heating operation (hot start) starts immediately.
* Once the operation mode is determined by automatic
operation, that operation mode does not change unless
the air conditioner is stopped once and restarted or by
changing to a different mode using the operation mode
select button.
2
The 3 temperature settings listed below can be selected for
automatic operation:
*
High
: +2 degrees up
*
Standard
: +0
*
Low
: –2 degrees down
Untitled-10