Panasonic CS-CE12GKEW Service Manual - page 7
7
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASG20K1
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
—
70
Output Power
W
30
30
Fan Speed
Q-Lo (Cool/Heat)
rpm
780 / 1090
—
Lo (Cool/Heat)
rpm
920 / 1150
—
Me (Cool/Heat)
rpm
1175 / 1325
—
Hi (Cool/Heat)
rpm
1430 / 1500
830 / —
SHi (Cool/Heat)
rpm
1470 / 1540
—
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 24 x 17
Size (W x H x L)
mm
610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
—
Type
One-Touch
—
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 915 (185 ~ 1180)
Heating; 1260 (175 ~ 1890)
Starting Current
A
5.8
Running Current
A
Cooling; 4.2
Heating; 5.8
Power Factor
%
Cooling; 95
Heating; 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
8.7
Power Cord
Number of core
—
Length
m
—
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT