Panasonic CS-E12BKP Supplemental Service Manual - page 5
New
Piping size Common
Length
(m)
Max.
Elevation
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Model
Gas Liquid
E9BK
3/8”
1/4”
7.5
5
15
10
2.2.4. Low Pressure Control (Gas Leakage Detection) (Page: 29)
Conditions
E9BKP
E12BKP
Cooling/Soft Dry
Heating
Cooling/Soft Dry
Heating
1. Compressor frequency (Hz)
47
56
67
68.5
Note: Conditions 1 and 2 needed to be happened continuously for 5 minutes.
2.2.5. Low Operation Frequency Protection Control (Page: 30)
Temperature, T, for:
Cooling/Soft Dry
Heating
Indoor intake air (°C)
T
30
—
Outdoor air (°C)
T
38
T
24
2.2.6. Anti-Fog Discharge Control (Page: 32)
Operation time, T (min)
E9BKP
E12BKP
0
30
Max 33 Hz
Max 44 Hz
30
90
Max 26 Hz
Max 36 Hz
90
420
Max 26 Hz
Max 36 Hz
2.2.7. Intake Air Temperature Control (Page: 33)
1. When the intake air temperature is 10°C or above and remote controller setting fan speed is Lo or lower.
2.2.8.
Auto Clean Deice Control (Page: 34)
3 Installation Instructions (Page: 54)
5
CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5