Panasonic CS-E12NKUAW Operating Instructions Manual - page 5
5
ENGLISH
•
Switch off the power at the circuit breaker before cleaning.
•
Do not touch the aluminium fi n, sharp parts may cause injury.
CLEANING INSTRUCTIONS
CLEANING INSTRUCTIONS
HINT
HINT
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 104°F/40°C.
• To ensure optimal performance of the unit, cleaning
maintenance has to be carried out at regular intervals. A
dirty unit may cause malfunction and you may see error
code “H99”. Please consult authorized dealer.
INDOOR UNIT
2
5
6
7
1
4
3
9
8
1
INDOOR UNIT
• Wipe the unit gently with a soft, dry cloth.
2
FRONT PANEL
Remove Front Panel
• Raise and pull to remove the front panel.
• Wash gently and dry.
Close Front Panel
• Press down both ends of the front panel to close it securely.
3
REMOTE CONTROL RECEIVER
4
ALUMINIUM FIN
5
HORIZONTAL AIRFLOW DIRECTION LOUVER
• Manually adjustable.
6
VERTICAL AIRFLOW DIRECTION LOUVER
• Do not adjust by hand.
7
AUTO OFF/ON BUTTON
• Use when remote control is misplaced or a malfunction occurs.
Step
Action
Mode
1
Press once.
Automatic
2
Press and hold until you hear one
beep, then release.
Force cooling
3
Repeat step 2. Press and hold
until you hear two beeps, then
release.
Normal cooling
4
Repeat step 3. Press and hold
until you hear three beeps, then
release.
Force heating
Press the button to turn off.
8
AIR PURIFYING FILTER
Vacuum the air purifying
fi
lter.
• It is recommended to clean the
fi
lter every 6 months.
• Replace the
fi
lter every 3 years or replace any damaged
fi
lter.
Part no.: CZ-SA20P
9
AIR FILTERS
• Air
fi
lter cleaning is required every two weeks.
• Wash/rinse the
fi
lters gently with water to avoid damage to the
fi
lter surface.
• Dry the
fi
lters thoroughly under shade, away from
fi
re or direct
sunlight.
• Replace any damaged
fi
lters.