© panasonic corporation 2013. Order no: papamy1303091ae indoor unit cs-me5pke destination europe please file and use this manual together with the service manual for model no. Cs-e7pkew cs-e9pkew cs-e12pkew cs-e15pkew cs-e18pkew cs-e21pkew cs-e24pkew cs-e28pkes, order no. Papamy1212045ce and cu-2e18...
2 caution before performing any of the electrical installation works, please verify on which of the intended connection use. Generally there are 2 types of indoor-outdoor connections: ○ a single connection (single indoor unit connects with single outdoor unit) ○ b multiple connection (multiple indoo...
3 table of contents 1. Safety precautions.............................................4 2. Specifications .....................................................6 3. Wiring connection diagram............................13 3.1 indoor unit..................................................13 4. Electroni...
4 1. Safety precautions read the following “safety precautions” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. The caution items stated here...
5 warning 20. During pump down operation, stop the compressor before remove the refrigeration piping. (removal of compressor while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.) 21. After co...
6 2. Specifications model indoor cs-me5pke performance test condition eurovent phase, hz single, 50 power supply v 230 min. Mid. Max. Kw 1.30 1.60 2.30 capacity btu/h 4430 5460 7840 running current a – 2.00 – input power w 250 400 640 annual consumption kwh – 200 – eer w/w 3.59 4.00 5.20 db-a 39 / 2...
7 model indoor cs-me5pke height (i/d) mm (inch) 295 (11-5/8) width (i/d) mm (inch) 870 (34-9/32) dimension depth (i/d) mm (inch) 255 (10-1/16) weight net (i/d) kg (lb) 10 (22) piping pipe diameter (liquid / gas) mm (inch) 6.35 (1/4) / 9.52 (3/8) inner diameter mm 16.7 drain hose length mm 650 fin ma...
8 multi split combination possibility: o a single outdoor unit enables air conditioning of up to two separate rooms for cu-2e15pbe, cu-2e18pbe. O a single outdoor unit enables air conditioning of up to three separate rooms for cu-3e18pbe. O a single outdoor unit enables air conditioning of up to f...
9 indoor unit : cs-me5pke outdoor unit : cu-2e15pbe 2room 1room indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) 1.6+1.6 3.2 1.6 1.6 1.6+2.0 3.6 2.0 2.0 1.6+2.5 4.1 2.5 2.5 1.6+2.8 4.4 2.8 2.8 1.6+3.2 4.8 3.2 3.2 2.0+2.0 4.0 2.0+2.5 4.5 2....
10 indoor unit : cs-me5pke outdoor unit : cu-3e18pbe 3room 2room 1room indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) 1.6+1.6+1.6 4.8 1.6+3.2 4.8 1.6 1.6 1.6+1.6+2.0 5.2 1.6+4.0 5.6 2....
11 indoor unit : cs-me5pke outdoor unit : cu-4e23pbe 4room 3room 2room 1room indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) 1.6+1.6...
12 4room 3room 2room 1room indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) indoor unit capacity (kw) total indoor capacity (kw) 2.0+2.5+2.8+3.2 10.5 2.8+2.8+3.2 8.8 2.0+2.5+3.2+3.2 10.9 2.8...
13 3. Wiring connection diagram 3.1 indoor unit.
14 4. Electronic circuit diagram 4.1 indoor unit.
15 5. Installation instruction 5.1 select the best location 5.1.1 indoor unit do not install the unit in excessive oil fume area such as kitchen, workshop and etc. there should not be any heat source or steam near the unit. there should not be any obstacles blocking the air circulation. a pl...
16 5.2 indoor unit 5.2.1 how to fix the installation plate the mounting wall shall be strong and solid enough to prevent it from vibration. Dimension model me5*** 490 mm 82 mm 439 mm 432 mm 43 mm 95 mm the centre of installation plate should be at more than ○ 1 at right and left of the wall. The dis...
17 5.2.3 indoor unit installation 5.2.3.1 for the right rear piping 5.2.3.2 for the right and right bottom piping 5.2.3.3 for the embedded piping.
18 (this can be used for left rear piping and bottom piping also.).
19.
20 5.2.4 connect the cable to the indoor unit 1 the inside and outside connection cable can be connected without removing the front grille. 2 connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5 mm 2 flexible cord, type designation 60245 iec 57 or ...
21 5.2.4.2 cutting and flaring the piping 1 please cut using pipe cutter and then remove the burrs. 2 remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe. 3 please make flare after inserting the f...
22 6. Exploded view and replacement parts list 6.1 indoor unit note the above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts..
23 safety ref. No. Part name & description qty. Cs-me5pke remark 1 chassy complete 1 cwd50c1730 2 fan motor 1 arw7667ac o 3 cross flow fan complete 1 cwh02c1137 4 bearing ass’y 1 cwh64k1010 4a screw - cross flow fan 1 cwh551146 5 generator complete 1 cwh94c0048 6 evaporator 1 cwb30c4016 7 flare nut ...
24 safety ref. No. Part name & description qty. Cs-me5pke remark 47 installation instruction 1 cwf615743 48 installation instruction 1 cwf615744 49 installation instruction 1 cwf615745 50 operating instruction 1 cwf568895 51 installation instruction 1 cwf615746 52 installation instruction 1 cwf61574...