Podab C 34-66 DGT Installation And Operation Manual - page 12
------------------------------------------- USE
Procedure in case of mains power down
No specific procedures need to be observed in case of interruption of mains power. When the mains power returns the
machine switches to idle-off (A-5 LED on).
Security devices
Water temperature
The machine is equipped with a boiler waiting device. If the boiler hasn't reached the preset temperature the washing
cycle continues until the preset value is reached. This means:
1)
the rinsing will always be done at the correct temperature not considering the feeding water temperature
2)
the washing cycle may last longer than the preset cycle time if the feeding water temperature is lower than the
one indicated in the technical data sheet of the machine.
Hood security
If the hood is lifted during a washing cycle or during regeneration, the program is interrupted and will only resume when
the hood is closed again. This device has no influence on the tank or boiler heating element and no effects during the
tank draining program.
Tank heating element protection
If the water level gets lower, the tank heating element is deactivated before it is reached by the water level to avoid
overheating the exposed heating element and to prevent user's from touching the hot heating element. This protection
device deactivates also the power supply to the boiler heating elements.
Alarm messages and machine state
The LED's may blink to indicate a technical problem or a machine state (phase running). The alarms do not block the
running cycle. It is recommended to call a qualified technical assistance to solve the inconvenience.
Machine state
LED 5
LED 6
Cycle: washing, pause, rinsing
OFF
Blinking 1 sec. period
Alarm no boiler heating
Blinking 0,3 sec. period.
Alarm hood lifted during cycle
Blinking 0,5 sec. period.
Blinking 1 sec. period.
Manual draining
Blinking 1 sec. period.
Regeneration cycle
Blinking 1 sec. period.
Continuous washing cycle
Blinking 1 sec. period.
Machine off (stand by)
ON
Alarm regeneration
Blinking 1 sec. period.
Thermometer alarm (where fitted)
If the temperature probe is disconnected or interrupted the tank or boiler display
(A-3 or A4) show
If the temperature probe is in short circuit or the temperature is higher than 107°C
the tank or boiler display (A-3 or A4) show
Check-list
Before starting to use the machine, check the following:
1) The water level and its temperature.
2) The detergent level.
3) The rinse-aid level.
4) The temperature of the water supply.
5) The washing agents (supply tube filled, tank holes are clean).
Water must be distributed, at high pressure, from all the sprayers. The rotary wash and rinsing arms must be free to
rotate by the water pressure. With every wash cycle the dispensers must draw the proper amount of rinse-aid and
detergent. Check the levels of the liquids in the containers and, if necessary, replace them or top them up.
The pump filter must be clean.
When the wash cycle is finished, the clean dishes must dry almost instantly by evaporation when the basket is removed
16