Podab C 34-66 DGT Installation And Operation Manual - page 7
INSTALLATION
ELECTRICAL CONNECTIONS
AN EFFICIENT EARTHING SYSTEM GUARANTEES THE SAFETY OF THE OPERATOR AND THE APPLIANCE.
This is an essential requirement that must be checked and, if in doubt, have the entire electric system checked by the
qualified personnel which made the connections to the electric mains. THE MANUFACTURER WAIVES ALL
RESPONSIBILITY FOR ANY DAMAGE CAUSED BY LACK OF AN ADEQUATE EARTHING SYSTEM FOR THE
APPLIANCE.
It is strictly forbidden to use plug adapters, multiplication plugs and extension cords.
Verify that the electric power supply complies with the technical specifications. The machine must be part of an
equipotential system, in accordance with European regulations. Connect it using the screw (C-9) with the mark, on the
back of the machine.
The connection to the electric mains must be done using a multi polar magnetothermic differential switch rated with a
contact gap equal to or larger than 3 mm.
When selecting the type and size of the power cable consider: the distance between the machine and the power
connection point, the installed power indicated on the ratings plate and the mains tension. The cross section of the
cables must not be less than 2,5 mm
2
. Use a H07RN-F cable and connect it to the provided terminal board and block
with cable clamp. Both components are as standard equipment. Avoid any strain on the power cable.
Verify the safety thermostat of the boiler F-B3 (if mounted) by pressing the reset button. The machine is set with a boiler
temperature of 85°C. To change the temperature turn the regulation screw of the thermostat F-B1.
ACCESSORIES
The machine can be fitted with retrofit accessories at a later date even on standard versions and available upon request:
- peristaltic detergent dispenser
- peristaltic rinse-aid dispenser
- drain pump
- rinse pump
Maintenance of the peristaltic dispensers: replacing the internal tube:
1) remove the transparent cover.
2) to remove it place the roller case vertically;
3) remove the coupling on the left of the pump from its seat by pulling the tube upwards and following its full length, then
turn the roller case clockwise until the coupling on the right of the pump can be extracted;
4) to mount it place the roller case horizontally;
5) push down the coupling on the left of the pump, with the curved part facing the bottom.
6) press the tube into its seat, gradually along its full length, and then manually turn the roller case clockwise until the
right-hand coupling is also inserted correctly;
7) fix the protection cover again then place the dispenser in the appropriate seat.
Use the regulation screw of the dosing unit (Fig.H.). By turning it clockwise or anti-clockwise the product quantity is
increased or decreased. The dosing times go from 1 to 25 seconds.
A 0.2 g quantity of rinse-aid corresponds to 2 cm in the transparent feed tube (cross-section 4x7 mm).
The dispensers must never be used when empty, or allowed to become empty.
Read the unit “Peristaltic dispensers” in the section “Use” to fill the dispenser and the dispenser/tank connection tube.
SAFETY PROVISIONS AND USER TRAINING
The skilled personnel performing the installation and the electric connections are requested to instruct the user aptly
about the functions of the appliance and the safety provisions to respect.
The personnel installing the machine must give the end user a practical demonstration of how to use the appliance and
hand out the written instructions which are delivered together with the appliance.
11