Protemp PT-100V-GFA-EU User's Manual & Operating Instructions - Ventilation
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
© 2017, Obelis S.A.
Gas Forced Air Heater User’s Manual
®
Ventilation
–
Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in
well ventilated areas.
–
Refer to Safety Information on pages 1-2
for information about Carbon Monoxide
Poisoning.
–
ALWAYS provide a fresh air opening in
the heated space. Minimum ventilation
requirements: Room volume should not
be less than 100 m
3
; minimum ventilation
of 25 cm
2
per kW of heat input subject to
a minimum of 250 cm
2
. As an example, a
150V-GFA-EU will require:
‒ A two car garage door open 16 cm or
‒ A single car garage door open 23 cm or
‒ Two 82 cm wide windows
open 38 cm.
Minimum Ventilation Opening Needed
PT-40-
GFA-EU
PT-60V-
GFA-EU
PT-100V-
GFA-EU
PT-150V-
GFA-EU
1110 cm
2
1670 cm
2
3530 cm
2
4180 cm
2
1.2 ft.
2
1.8 ft.
2
3.8 ft.
2
4.5 ft.
2
Min. Room Dimensions ≥ 100 m³
Min. Ventilation ≥ 250 cm²
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
DANGER
Not for use in residential
living areas or in
non-adequately ventilated enclosed spaces.
DANGER
Storage / Maintenance
Always disconnect the heater from the gas
cylinder before putting the heater into storage. If
for any reason the heater is to be stored indoors,
the tank MUST be disconnected from the Gas
cylinder, and the cylinder stored outdoors in a
well-ventilated area, out of the reach of children.
The plastic valve plug or valve cover supplied
with the cylinder must be re-installed on the valve
to protect the fitting from damage.
If the supply cord is damaged, it must be
replaced by a special cord or assemble available
from the manufacturer or its service agent.
NOTE: Installation and repair of this heater
should be done by a qualified service person.
ALWAYS be sure to follow proper maintenance
procedures. This should include cleaning the
inside of the heater once a month and checking
the spark gap at least once a heating season.
Re-gap the terminals to 4mm.
8
Never store an gas cylinder
inside of a building or near
any other gas or oil burning appliances.
DANGER