Protherm 24(12) KTO Operation And Installation Manual - Boiler Control
9
Starting up the boiler
Important:
Putting the boiler into operati-
on and starting it up for the fi rst time must
be performed by an authorised service
only!
If you wish to start the boiler up after it has
been put into operation, make sure that:
1 the boiler is connected to the electrical
power supply;
2 all isolation valves (heating water, hot
water, gas) underneath the boiler are
opened;
3 the heating water pressure is within the
recommended range of 1 – 2 bar
Turn the main switch (Fig. 1, position 1).
After a short time the heating water tem-
perature appears on the display and the
LED by the
symbol is lit (Fig. 1, position
2). After ignition of the burner the LED by
the symbol
is lit (Fig. 1, position 6).In
the event of a safety boiler shutdown
the red malfunction LED
is lit on the
control panel (Fig. 1, position 5), and an
error code appears on the boiler display.
Unblock the boiler by pressing the RESET
button (Fig 1, position 9). If safety shut-
down recurs after a short time again, or
if the boiler cannot be unblocked by pres-
sing the RESET button, call an authorised
service organisation.
Shutting the boiler down
Switch off the main switch (Fig. 1, position
1).
If the boiler is to remain shut down for a
longer period of time, close all cocks (hea-
ting water, hot water, gas) underneath the
boiler. Shutting down the boiler must be
performed taking into account the heating
water temperature in the boiler and the
surrounding environmental temperatu-
re in the given season of the year. In the
case of danger that the boiler may freeze,
discharge the water from the boiler, hea-
ting system and hot water distributors.
Starting up and shutting down boiler
Boiler control
Using the boiler without a room
control unit
When running in this mode, the boiler
maintains the selected heating water
temperature. No room control unit is con-
nected, the terminals for its connection
must be mutually interconnected (stan-
dard factory setting).
Setting procedure:
• turn the main switch to the ON position;
• set the required heating water tempera-
ture on the control panel.
Operation of boiler with room
control unit
In the case that a room control unit is
used, it is necessary to set the maximum
Heating Water temperature for which your
heating system has been designed, and
which is capable of covering the thermal
loss of the building even at low outside
temperatures, on the control panel of
the boiler (in order to prevent damage to
the system). The process of heating the
heating water can then be controlled by a
control unit only up to the maximum value
of the heating water you have set on the
control panel of the boiler.
Note:
Thermostatic valves should not be
fi tted on the radiators in the room where
the control unit is installed
Caution:
The manufacturer does not
accept responsibility for damage caused
by faulty setting of the boiler or room con-
trol unit.