ProVisual AC-930P Installation Manual

Manual is about: CCTV & Security Distributor Integrated Access Controller

Summary of AC-930P

  • Page 1

    Technical innovation 0 45 human-centered design quality assurance sincere and faithful integrated access controller installation manual led 1 2 3 4 5 6 7 8 9 0 # 3000 provisual, inc. Cctv & security distributor integrated access controller installation manual.

  • Page 2

    Home & business security solutions.

  • Page 3: Product

    Provisual integrated access control series: ac-930p anson integrated access control is characterized by its elegant design and convenient application and installation, which is especially suitable for office buildings and shops. The device is equipped with built-in reader and can work both as contro...

  • Page 4: Common Question

    1. If there is no sound when card is presented to the reading area, the reading function maybe damaged. 2. If there is no sound when press the keys, the keypad maybe damaged. 3. When add card, if the device exits program mode automatically, the memory maybe damaged. 4. If valid card is read and ok l...

  • Page 5: Product

    1 2 3 4 5 6 7 8 9 0 # 1 5 0 m m 8 8 m m 30mm 设 备参 数 product manual 485 232 gnd 12v dat0 dat1 sw gnd menc1 bell bell rx tx gnd 485+ 485- 2c 2no 1no 1c 1nc gnd fixing hole jumper the back fixing hole fixing hole the side the front working voltage: dc9-15v static current:≤120ma reading distance: 5-10cm...

  • Page 6

    1. Remove the two keys first. 2. Unfasten the two screws. Push up the back cover to open first open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device. 3. Open the back cover and connect the device according to the wiring diagram. 4. Fix the b...

  • Page 7

    Connect with electric bolt p o w e r in te rf a c e ac-9 30 p interface +12v gnd connect with power +12v gnd v+ v- no com nc connect with em lock + - +12v gnd fail-safe fail-secure +12v gnd signal signal +12v gnd gnd 12v dat0 dat1 sw gnd menc1 bell bell rx tx gnd 485+ 485- 2c 2no 1no 1c 1nc gnd gnd ...

  • Page 8

    Com1 com2 exit button for this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, the opening time depends on the door- open delay time. It is recommended to install ultra-red and ground sensor for protec...

  • Page 9

    Connect with rs485 for 485 communication, please follow the diagram for connection and no other connection mode should be used. Converter 485+ 485- 12345 db9-hole computer interface gnd 12v da t0 da t1 sw gnd menc1 bell bell rx tx gnd 485+ 485- 2c 2no 1no 1c 1nc gnd 12345 gnd 12v da t0 da t1 sw gnd ...

  • Page 10

    A gnd 12v da t0 da t1 sw gnd menc1 bell bell rx tx gnd 485+ 485- 2c 2no 1no 1c 1nc gnd gnd 12v da t0 da t1 sw gnd menc1 bell bell rx tx gnd 485+ 485- 2c 2no 1no 1c 1nc gnd 1 2 3 4 5 6 7 8 9 0 # invalid card: if the reader sounds twice after the card is presented to the reading area for one second, t...

  • Page 11

    After the exterior device is connected with ac-930p, please select tools---card register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly. Connect with exterior identificati...

  • Page 12: Common Question

    Urgent maintenance: 1. When the exterior reader can not read the cards, please test the voltage of data0—gnd and data1---gnd. If the voltage is less than 3.5v, please weld tvs2, tvs3. 2. When door magnet input fails, please test the voltage between menci and gnd. If the voltage is less than 3.5v, pl...