Invalid Card: If the reader sounds twice after the card is
presented to the reading area for one second, the card is invalid.
Valid Card: If after the card is presented to the reading area for
0.5 seconds, the reader sounds once, green lights on and
delay acts, then the card is valid.
When the buzzer sounds once,
Dial “*”, the orange light flashes; Input“000000”, the orange
light turns on and device enters program mode. This means
the keypad is OK.
1
,
1
1
Adjust the multimeter to
, When the power is on,
in normal state, 1C- NC is short circuit
while
C- NO
is open circuit. When present the valid card or press
the exit button, 1C-1NC turns into open circuit, while 1C-
1NO is short circuit.
1C
1NC
1NO
1C
1NC
1NO
Normal State
Door-open State
Test Reading
Card
Test
the
Keypad
Test Output
Test Input
If valid default input is normal open, no input available for the
device when input signal is open-circuit; while input available
when input signal is close-circuit. The status reversed when
valid default input is normal close. The user can decide the
type of default input setup in the software. AC-930P has two
input interfaces: SW-GND is button input; MenCi- GND is door
magnet input. Both of them can be changed in “channel setup”.
Test
Reading Card
AC-930P Interface
AC-930P Interface