9.3 Choice of flue:
The following flue kits are available for connecting to the boiler:
A
Standard coaxial horizontal flue kit (Exhaust & intake outside)
Figure 9.3 (Coaxial 2.4/4.0 inches – nominal lenght 3.3 ft)
It can be fitted to allow discharge to the rear or either side of the boiler via the
flanged boiler adapter elbow. Minimum lenght required is 1 ft. Maximum equivalent
lenght of 32.8 ft can be achieved utilising extensions. This flue system can only be
used to discharge horizontally; it is not designed to enable termination in the
vertical plane.
Installation:
• Drill hole A (on the wall template) through the outside wall that is less than 18”
thick.
• Cut the pipes as necessary so that a no more than 6” protrudes from the house.
• Slide the intake and exhaust pipes through the hole.
• Slide one rubber wall trim piece on the pipe from inside and one from outside.
• Connect exhaust (inner) pipe to concentric elbow.
• Connect intake (outer) pipe to concentric elbow.
• Secure elbow to boiler using gasket and four screws provided.
• Secure end cap on the intake pipe outside the house.