QSC GXD Quick Start Manual - page 6
6
TD-000449-00-C
PRESET SAVE AS
Select the LOCATION and/or change the NAME to save changes you make to the DSP.
See
Figure 17
and
Figure 18
1. From HOME
ENTER
2.
B
PRESET,
ENTER
3.
B
PRESET SAVE AS,
ENTER
4.
B
LOCATION
ENTER
5.
B
the LOCATION (P1 to P20),
ENTER
6.
B
NAME,
ENTER
7.
B
letter, number, hyphen, or space
ENTER
repeat. When fi nished
EXIT
8.
B
SAVE,
ENTER
ENTER
STEREO DSP or DSP A and DSP B
STEREO DSP is set for both channels equally, at the same time. Separate DSPs (DSP A and DSP B) are set independently for each channel. The
Sensitivity controls are linked in both Stereo DSP and dual mono DSP. Switching between Stereo DSP and Separate DSP is done by recalling presets
that are either stereo or dual mono.
Any changes you make are made in real time – you hear the change as it is being made.
NOTE:
The term "STEREO DSP" is used in this document as a generic term to mean either STEREO DSP or DSP A/DSP B, unless
specifi cally noted.
SENSITIVITY
See
Figure 19
1. From HOME
ENTER
2.
B
STEREO DSP,
ENTER
3.
B
SENSITIVITY,
ENTER
4.
B
1.2 V (+4 dBu), 3.9 V (+14 dBu), or TouchMix
™,
ENTER
CROSSOVER and POLARITY
See
Figure 20
through
Figure 22.
1. From HOME
ENTER
2.
B
STEREO DSP,
ENTER
3.
B
CROSSOVER,
ENTER
4.
B
HPF,
ENTER
5.
B
FREQUENCY (BYPASS, 20 Hz to 4 kHz),
ENTER
6.
B
LPF,
ENTER
7.
B
FREQUENCY (BYPASS, 60 Hz to 4 kHz),
ENTER
8.
B
POL,
ENTER
9.
B
positive (+) or negative (-),
ENTER
HOME
— Figure 17 —
PRESET > SAVE AS
ENTER TO SELECT
P20: MONO SUBS 100 HZ
LOCATION
NAME
SAVE
— Figure 18 —
PRESET > SAVE AS
ENTER: PRESS TO ADVANCE
P20:
M
ONO SUBS 100 HZ
HOLD TO ACCEPT
— Figure 19 —
DSP > SENSITIVITY
SENSITIVITY: 3.9V (+14dBu)
SENSITIVITY: 3.9V (+14dBu)
— Figure 20 —
CROSSOVER > HIGHPASS
FREQUENCY: 60 Hz
HPF
POL
LPF
0
-6
— Figure 21 —
CROSSOVER > LOWPASS
FREQUENCY: 2000 Hz
0
HPF
POL
LPF
-6
— Figure 22 —
CROSSOVER > POLARITY
POLARITY: +
HPF
POL
LPF
+