QSC RMX 1450 Service Bulletin

Manual is about: RMX Series

Summary of RMX 1450

  • Page 1

    1 rmx0002 title: rmx turn-on delay bulletin #: rmx0002 issue date: september 28, 2000 models affected: rmx 850, 1450 & 2450 bulletin revision: a production range: 01/2000–08/2000 service bulletin description some rmx series amplifiers take longer than 10 seconds to fully turn on. This is caused by t...

  • Page 2

    2 rmx0002 3. With long-nose pliers, hold one of the lead remnants. Melt the solder with the iron, then pull the lead out of the circuit board. Use braid or desoldering equipment to remove excess solder from the hole. Repeat for the three other lead remnants. 4. Twist the anode lead of a new 4.7-volt...

  • Page 3

    3 rmx0002 4. Twist the anode lead of a new 4.7-volt zener diode with one lead of a 180 Ω resistor to form a “v” and solder them together; trim the excess. Repeat for the other three diodes and resistors. See figure 3. 9. Insert the diode/resistor combinations into the circuit board. Make sure they a...

  • Page 4: Contact Information

    4 rmx0002 bias adjustment (perform only with unit at ambient temperature) note: this calibration must be done with the amplifier circuitry at ambient temperature. If the amp has begun to warm up, you must turn it off and wait until it cools down. 6. Measure the dc voltage across r146. Adjust bias tr...