IMPORTANT INFOMATION:
This product is a Class 3B laser and should only be installed and used by personal who are
trained in the management of laser radiation and are able to operate in accordance within the
guidance given by the Health and Safety Executive (HSE) in HS(G)95: “The Radiation Safety of
Lasers used for Display purposes”.
Copies of this guide can be downloaded from the HSE website below:
www.hse.gov.uk/pubns/priced/hsg95.pdf
This product contains no user-serviceable parts. Under no circumstances should any attempt
be made by the user to dismantle or modify it in any way.
INSTALLATION AND MOUNTING INSTRUCTIONS:
This product must be securely mounted so that its emission is always directed away from
people and objects that are able to reflect the emission towards people. In this regard the
separation distances of 3 metres vertically and 2.5 metres horizontally, cited in HS(G)95 and
shown overleaf must be observed.
152.762UK User Manual
DMX
The fixture is equipped with 3-pin XLR connectors for DMX input and output. The SE
connectors are wired in parallel. Only use a shielded twisted-pair cable designed for 3-pin XLR-
plugs and connectors in order to connect the controller with the fixture or one fixture with
another.
Building a serial DMX-chain:
Caution: At the last fixture, the DMX-cable has to end with a terminator. Solder a 120 Ohm
resistor between PIN 2 (-) and PIN 3 (+) into a 3-pin XLR-plug and plug it in the DMX-output
of the last fixture.
When in DMX mode there are two channels with the following function: