Frequently Asked Questions About the ES-500 Controller and
Quad Systems, LLC. EZ-4000 Operators
Q. Can the Quad Systems operator be used with a Horton control?
A. Yes, in most cases the ES-4000 operator can be used with the Horton C4160-1,
C4160-2, C4190, or C7160-3 controls. An adapter harness would be required to allow the
EZ-4000 to plug into the Horton control. The harness would have the proper connectors
on each end and would also include the brown wire for the open check micro-switch,
which Horton's C7160-3 control requires (Quad Systems ES-500 control does NOT
require this connection, so it is not present in the current operator wiring harness).
Q. Can our control be used with a Horton operator?
A. Yes, the ES-500 can be used with the Horton S7000 or S4000 operator. An Adapter
harness (part number 600-0011-02) is required and includes detailed installation
instructions.
Q. How do I easily adjust the cams?
A. Place switch on "Hold-Open" (=) position and let the door open to the full open position.
Loosen the small Allen head screws on the outside cam (switch with 2 wires). Rotate the
cam until the switch is on the flat part of the cam and tighten screw. Place switch in the
"Off" (o) position and let the door close completely. Loosen the small Allen head screws
on the inside cam (switch with 3 wires). Rotate the cam until the switch is on the flat part
of the cam and tighten screw.
Q. I need a motion sensor (or a door mounted approach sensor) that is disabled
when the door is fully closed--that is, I only want it to function as a recycle and hold
open device for additional safety. It must be ignored when the door is closed. How
can I make this possible?
A. This feature is supported beginning in Versions 1.02/1.03. An auxiliary harness (Close
Monitor harness, (part number 600-0008-01) will be required. Set the AF parameter to
2*. Wire the additional sensor's output contact to the red and black wires of the auxiliary
harness.