Quadra-Fire 31I-ACC Installation Manual

Manual is about: 3100-I ACC WOOD INSERT Automatic Combustion Control (ACC)

Summary of 31I-ACC

  • Page 1

    1 7044-225d august 3, 2015 3100-i acc wood insert automatic combustion control (acc) model(s): 31-i acc o-t l tested and listed by portland oregon usa omni-test laboratories, inc. C us hot surfaces! Glass and other surfaces are hot during operation and cool down. Hot glass will cause burns. • do not...

  • Page 2

    2 7044-225d august 3, 2015 31-i acc 1 important safety information a. Insert certifi cation .............................................................3 b. Btu & effi ciency specifi cations........................................3 c. Mobile home approved ..............................................

  • Page 3

    August 3, 2015 7044-225d 3 31-i acc model: 3100-i (acc) insert laboratory: omni test laboratories, inc. Report no: 061-s-74-6.2 type: solid fuel type, listed room heater standard: ul1482 and ulc s628-93 and (um) 84-hud, mobile home approved. 1 important safety information a. Insert certifi cation no...

  • Page 4: Install Guide

    4 7044-225d august 3, 2015 31-i acc install guide 2 getting started a. Design and installation considerations before installing, determine the following: • type of chimney connector to be used · single wall, 6 inch (152mm) diameter, stainless steel, or · double wall, 6 inch (152mm) diameter, stainle...

  • Page 5

    August 3, 2015 7044-225d 5 31-i acc c. Negative pressure negative pressure results from the imbalance of air avail- able for the appliance to operate properly. It can be stron- gest in lower levels of the house. Causes include: • exhaust fans (kitchen, bath, etc.) • range hoods • combustion air requ...

  • Page 6

    6 7044-225d august 3, 2015 31-i acc attention installer: follow this standard work checklist this standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: date installed: lot/address: location of fir...

  • Page 7

    August 3, 2015 7044-225d 7 31-i acc figure 7.1 top view figure 7.2 front view figure 7.3 - side view a b 27-5/8 in (702mm) 23-13/16 in (589mm) 38-9/16 in (979mm) 5-1/2 in (140mm) 5-11/16 in (144mm) 8-1/2 in (216mm) c l 7-3/4 in (197mm) 12-1/2 in (318mm) 26-3/4 in (679mm) 23-1/4 in (591mm) 14-1/4 in ...

  • Page 8

    8 7044-225d august 3, 2015 31-i acc note: clearances may only be reduced by means approved by the regulatory authority having jurisdiction fire risk. • comply with all minimum clearances to combustibles as specifi ed. • failure to comply may cause house fi re. Warning in canada a full length 6 inch ...

  • Page 9

    August 3, 2015 7044-225d 9 31-i acc c. Calculating alternate floor protection material thermal conductivity: k value the k value indicates the amount of heat (in btu’s) that will fl ow in 1 hour through 1 square foot of a uniform material 1 inch thick for each degree (f) of temperature difference fr...

  • Page 10

    10 7044-225d august 3, 2015 31-i acc figure 10.1 recommended location marginal location location not recommended recommended location location not recommended multi-level roofs windward leeward outside air kit termination cap e. Chimney termination requirements follow manufacturer’s instructions for...

  • Page 11

    August 3, 2015 7044-225d 11 31-i acc 3 ft. (91cm) minimum less than 10 ft. (305cm) 2 ft. (61cm) 3 ft. (91cm) minimum 10 ft. (305cm) to nearest roofline 2 ft. (61cm) pitched roof figure 11.1 figure 11.2 10 ft. (305cm) or more 3 ft. (91cm) minimum less than 10 ft. (305cm) 2 ft. (61cm) minimum 3 ft. (9...

  • Page 12

    12 7044-225d august 3, 2015 31-i acc 4 chimney systems d. Masonry chimney • must meet minimum standards of nfpa 211. • must have at least 5/8 inch (16mm) fi reclay lining joined with refractory cement. (installations into a clay fl ue without a stainless steel liner may reduce draw which affects per...

  • Page 13

    August 3, 2015 7044-225d 13 31-i acc ul 1777 insulated stainless steel liner or other approved lining system follow manufacturer’s instructions on insulation and support for zero or other non-code clearances, follow approved liner manufacturer’s specific insulation requirements: different clearances...

  • Page 14

    14 7044-225d august 3, 2015 31-i acc f. Prefabricated metal chimney figure 14 .1 e. Metal heat circulating masonry the chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements: • must be minimum 6 inch (152mm) inside diameter of high temperature chimn...

  • Page 15: Warning

    August 3, 2015 7044-225d 15 31-i acc inches millimeters minimum width of cavity opening - front 29-1/16 738 minimum width of cavity opening - rear 25-1/2 648 minimum height 20-3/4 528 minimum depth from front to rear 17-9/16 446 damper smoke shelf or baffl e ember catches fire grate viewing screen/c...

  • Page 16

    16 7044-225d august 3, 2015 31-i acc ovalizing round stainless steel liners to accommodate the liner passing through the damper region of a fi replace is an allowable and acceptable practice. Ensure that the ovalization is minimized to the extent required to fi t through the damper. J. Ovalizing rou...

  • Page 17

    August 3, 2015 7044-225d 17 31-i acc figure 17.1 outside air cover plate (discard) rectangular outside air cover (included with side panel assembly) termination cap flex adapter a. Outside air kit installation items needed for installation (not supplied) • 4 inch fl ex aluminum pipe, or if using alt...

  • Page 18

    18 7044-225d august 3, 2015 31-i acc b. Disassemble firebox and outer can for easier fi eld installation the outer can is installed with- out the fi rebox so connecting to the fl ue has greater access. The fi rebox slides into the outer can once the fl ue collar is attached to the stove pipe/liner a...

  • Page 19

    August 3, 2015 7044-225d 19 31-i acc figure 19.2 figure 19.3 figure 19.4 cast iron flue located on appliance drill through all 8 countersunk locations once distance is established, drill holes and secure both chambers together. Figure 19.5 c. Securing stove pipe/liner to flue collar 1. There are 4 p...

  • Page 20

    20 7044-225d august 3, 2015 31-i acc figure 20.5 figure 20.4 secure 2 side surrounds to top surround attachment holes to outer can figure 20.6 top surround side surround # 8 screws f. Surround & trim kit installation 1. Lay surround face down on a protected surface to pre- vent scratching. 2. Using ...

  • Page 21

    August 3, 2015 7044-225d 21 31-i acc remove 2 screws from both sides. Adjust the legs up or down to level appliance. Figure 21.4 i. Leveling legs 1. Remove the 2 screws already installed on each leg. 2. Move legs to the desired height . 3. Re-install the screws to secure in place. G. Installing fire...

  • Page 22

    22 7044-225d august 3, 2015 31-i acc j. Snap disc and side panel installation 1. Place snap disc box in location shown in figure 22.1. 2. Secure the wires through the wire clip to keep in place. 3. Route the blower wires underneath appliance through the wire channel to the other side of the applianc...

  • Page 23

    August 3, 2015 7044-225d 23 31-i acc strain relief green ground wire & nut disconnect wires from wire harness strain relief green ground wire & nut white (neutral) wire male spade terminal clip all 3 zip ties male terminal female terminal male terminal wire 5 inches (127mm) longer speed control atta...

  • Page 24

    24 7044-225d august 3, 2015 31-i acc double-sided tape double-sided tape screws are circled exploded view of scissors figure 24.1 thermal protection decorative tile may be installed install front trim last. Corners overlap side trim pieces expand scissors to desired height cut top edge of trim, not ...

  • Page 25

    August 3, 2015 7044-225d 25 31-i acc figure 25.1 spark arestor cap roof flashing storm colla r joist shield/firestop double wall connector pipe 8. Burn wood only. Other types of fuels may generate poisonous gases (e.G., carbon monoxide). 9. If unit burns poorly while an exhaust blower is on in home,...

  • Page 26

    26 7044-225d august 3, 2015 31-i acc accessories adjustable hearth support - 12 in x 50 in, 2-10” h adjspt-12 side panel (w/blower) black sdpnl-31i-bk gold trim sdpnl-31i-gd nickel trim sdpnl-31i-nl surround, large 51” x 34” sp-31iacc-lrg surround, standard 43” x 31” sp-31iacc-std component pack srv...

  • Page 27

    August 3, 2015 7044-225d 27 31-i acc.

  • Page 28

    28 7044-225d august 3, 2015 hearth & home technologies 1445 north highway colville, wa 99114 division of hni industries we recommend that you record the following pertinent information for your 31-i acc wood stove date purchased/installed: serial number: location on appliance: dealership purchased f...