Quadra-Fire 57ST-ACC Owner's Manual - Caution
Page 2
7038-159C
February 5, 2010
R
5700 Step Top Wood Stove Series ACC
Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.
This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation
of our stoves, inserts and fireplaces. And yet we are old-
fashioned when it comes to craftsmanship. Each unit is
meticulously fabricated and gold and nickel surfaces are
hand-finished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection.
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Quadra-Fire.
and Welcome to the Quadra-Fire Family
!
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: Back of Appliance
A
B
C
D
E
F
G
H
SINGLE WALL PIPE
12.5 (318) 10.5 (267) 25.5 (648) 15 (381)
2 (51)
12 (305)
45 (1143)
N/A
DOUBLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)
2 (51)
12 (305)
45 (1143)
N/A
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)
**
**
45 (1143) 18 (457)
**
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine
UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, ou une
cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air
isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou
une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
MIN CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of flue collar.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES. (UM)
84-HUD .
"For Use with Solid Wood Fuel Only"
1445 N. Highway, Colville, WA 99114
www.quadrafire.com
Install and use only in accordance with
manufacturer's
installation
and
operating
instructions. Contact local building or fire officials
about restrictions and installation inspections in
your area. Do not obstruct the space beneath
heater.
WARNING - For Mobile Homes: Do not install in
a sleeping room. An outside combustion air inlet
must be provided and unrestricted while unit is in
use. The structural integrity of the mobile home
floor, ceiling and walls must be maintained. The
stove needs to be properly grounded to the frame
of the mobile home. Components required for
mobile home installation: Outside Air Kit, Part
Number 831-1780.
Refer to manufacturer's instructions and local
codes for precautions required for passing
chimney through a combustible wall or ceiling and
maximum offsets.
Inspect and clean chimney frequently - Under
Certain Conditions of Use, Creosote Buildup May
Occur Rapidly.
Do not connect this unit to a chimney serving
another appliance.
Optional Components: Optional Blower, Part
831-1701.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route
cord over or in front of appliance.
DANGER: Risk of electrical shock. Disconnect
power supply before servicing.
Replace glass only with 5mm ceramic available
from your dealer.
Do not use grate or elevate fire. Build wood fire
directly on hearth.
Do not overfire - if heater or chimney connector
glows, you are overfiring.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to
comply with July 1990 particulate emission standards.
2009 2010 2011 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
PREVENT HOUSE FIRES
Report / Rapport
#061-S-73-6.2
TESTED TO:/ TESTÉ À:
UL 1482, ULC S627-00
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
VENT SPECIFICATIONS:
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black
or blued steel connector pipe, with a listed factory-built UL103HT* Class "A"
chimney, suitable for use with solid fuels, or a masonry chimney, and the
referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney,
or a masonry chimney and the referenced clearances
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos
DS or Security DL double wall connector pipe. Must be equipped with a spark
arrestor. Apply double wall clearances below when installing unit.
R
7038-162
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT
PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR
L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION:
A
PPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec
Bois Solide Seulement"
Installez et utilisez en accord avec les instructions
d'installation et d'opération du fabricant. Contactez le
bureau de la construction ou le bureau des incendies au
sujet des restrictions et des inspections d'installation dans
votre voisinage. Ne pas obstruez l'espace en dessous de
l'appareil.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans
une chambre à coucher. Un tuyau extérieur de
combustion d'air doit être installé et ne doit pas être
obstrué lorsque l'appareil est en usage. La structure
intégrale du plancher, du plafond et des murs de la
maison mobile doit être maintenue intacte. L'appareil de
chauffage doit être fixé à la charpente de la maison
mobile. Les composants requis pour l'installation des
maisons mobiles: Assemblage d'air extérieur, Numéro de
Pièce 831-1780.
Référez vous aux instructions du fabricant et des codes
locaux pour les précautions requises pour passer une
cheminée à travers un mur ou un plafond combustibles,
et les compensations maximums.
Inspectez et nettoyez la cheminée fréquemment. Sous
certaines conditions, il se peut que la créosote
s'accumule rapidement.
Ne pas connecter cet appareil à une cheminée servant un
autre appareil.
Composants Optionnels: Ventilateur Optionnel, Pièce
#831-1701.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer
le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.
Déconnectez le fil électrique de la prise de contact avant
le service.
Remplacez la vitre seulement avec une vitre céramique
de 5 mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement
sur l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau
PRÉVENTION DES FEUX DE MAISON
ESPACES LIBRES MIN DES MATÉRIAUX COMBUSTIBLES:
En Pouces & (millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur
de l'entrée du conduit.
BACKWALL/SIDE
WALL
MUR
ARRIÈRE/MUR
DE CÔTÉ
CORNER
INSTALLATION
INSTALLATION
DU COIN
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in U.S.A./Fait Aux États-Unis
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
A
B
C
D
E
F
E
F
Manufactured by:
Fabriqué par:
INSTALLATION: FULL VERTICAL INSTALLATION: ENTIÈREMENT VERTICALE
SERIAL NO. / NUMÉRO DE SÉRIE
007007
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
5700 Step Top ACC
CONDUIT DU MUR SIMPLE
Test Lab and
Report Number
Model Name
Serial Number
Manufacturer Date
SAMPLE
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction