Explorer III Wood Stove
NOTE:OptionalFireScreen,PartSCR-7006,
canonlybeusedinFULLVerticalinstallations.
Chimney Height / Rise and Run
This product was designed for and tested on a 6 inch (152mm)
chimney, 14 to 16 feet (420-480cm) high, (includes appliance
height) measured from the base of the appliance. The further
yourstackheightordiametervariesfromthisconfiguration,
the possibility of performance problems exists.
Chimney height may need to be increased by 2 - 3% per
each1000feetabovesealevel.Itisnotrecommendedto
use offsets or elbows at altitudes above 4000 feet above sea
levelorwhenthereareotherfactorsthataffectfluedraft.
C. Installing Chimney Components
Chimney Connector
Singlewallconnectororappliancepipe.
This must be at least 24 gauge mild steel or 26 gauge blue
steel. The sections must be attached to the appliance and
to each other with the crimped (male) end pointing toward
theappliance.Alljoints,includingtheconnectionattheflue
collar,shouldbesecuredwith3sheetmetalscrews.Make
sure to follow the minimum clearances to combustibles.
Wherepassagethroughthewall,orpartitionofcombustible
construction is desired in Canada, the installation shall con-
formtoCAN/CSA-B365.
Factory-builtlistedchimneyconnector(vented).
A listed connector (vented) must be used when installing
this appliance in a mobile home. The listed connectors must
conformtoeachothertoensureaproperfitandseal.
Flue Gas
Direction
Crimped
End
Toward
Appliance
Secure pipe sections with a
minimum of 3 screws
Figure 14.2 Chimney Connector (Appliance Pipe)
WARNING
Asphyxiation Risk
• DONOTCONNECTTHISApplianceTOACHIM-
NEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Mayallowfluegasestoenterthehouse.
Improperinstallation,adjustment,alteration,serviceormain-
tenance can cause injury or property damage. Refer to the
owner’sinformationmanualprovidedwiththisappliance.For
assistanceoradditionalinformationconsultaqualifiedinstaller,
service agency or your dealer.
WARNING
Fire Risk
InspectionofChimney:
• Chimney must be in good condition.
•MeetsminimumstandardofNFPA211
• Factory-builtchimneymustbe6inch(152mm)UL103HT.
WARNING
WARNING
Fire Risk
FollowChimneyConnectorManufacturer’sInstructions
forProperInstallation.
ONLYuseconnector:
• Withintheroom,betweenapplianceandceilingor
wall.
ConnectorshallNOTpassthrough:
• Attic or roof space
• Closet or similar concealed space
• Floororceiling
Maintain minimum clearances to combustibles
Chimney Flue
Liner
Fireclay
Liner or
Equivalent
Masonry Chimney
Constructed to NFPA 211
Wall Spacer
Wall Band
Trim Collar
Chimney
Connector
1 inch (25mm) Air
Space to Chimney
Section
Min. Clearance
2 inch (51mm)
Min. Chimney Clearance to
Wall Spacer and
Combustibles - 2 inch (51mm)
Chimney Section
Figure 14.1
Solid Pack Chimney with Metal Supports as a Thimble
(Cont’d)