Quadra-Fire MTVERNINSAE-CSB Installation Manual

Manual is about: MT VERNON PELLET INSERT ADVANCED ENERGY

Summary of MTVERNINSAE-CSB

  • Page 1

    1 7036-188e may 5, 2015 mt vernon pellet insert advanced energy (ae) model(s): mtverninsae-mbk mtverninsae-pmh mtverninsae-csb installation manual installation & appliance set-up installer: leave this manual with party responsible for use and operation. Owner: retain this manual for future reference...

  • Page 2

    2 7036-188e may 5, 2015 mt vernon ae insert 300 watt igniters come installed in brand new mt. Vernon ae units and are for pellet fuel only. The 380 watt igniter is required for burning multi-grain fuels and is included in the component pack. Multi-fuels include, corn, sunfl ower seeds, and wheat. Ta...

  • Page 3

    May 5, 2015 7036-188e 3 mt vernon ae insert model mt. Vernon pellet insert ae laboratory omni test laboratories, inc. Report no. 061-s-69-6 type solid fuel room heater/pellet type insert standard astm e1509-04, ulc s628-93 and ulc/ord-c1482-m1990 room heater pellet fuel burning type and (um) 84-hud,...

  • Page 4: Install Guide

    4 7036-188e may 5, 2015 mt vernon ae insert install guide 2 getting started marginal location: • below peak location not recommended: • not the highest point of the roof • wind loading possible multi-level roofs windward leeward recommended: outside air intake on windward side not recommended: outsi...

  • Page 5

    May 5, 2015 7036-188e 5 mt vernon ae insert hearth & home technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: • installation & use of any damaged appliance. • modifi cation of the appliance. • installation other than as instructed by hearth & hom...

  • Page 6

    6 7036-188e may 5, 2015 mt vernon ae insert attention installer: follow this standard work checklist this standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: date installed: lot/address: locatio...

  • Page 7

    May 5, 2015 7036-188e 7 mt vernon ae insert figure 7.3 - front view with basic surround panel set figure 7.1 - top view figure 7.2 - side view 26-1/4 in. (667mm) 13-1/8 in. (333mm) 15 in. (382mm) 23-7/8 in. (606mm) 32 in. (812mm) 8-1/8 in. (206mm) 2-3/8 in. (59mm) cl 29-3/4 in. (756mm) 23-7/8 in. (6...

  • Page 8

    8 7036-188e may 5, 2015 mt vernon ae insert note: • illustrations refl ect typical installations and are for design purposes only. • i llustrations/diagrams are not drawn to scale. • actual installation may vary due to individual design preference. B. Clearances to combustibles (ul and ulc) fire ris...

  • Page 9

    May 5, 2015 7036-188e 9 mt vernon ae insert e. Minimum opening for masonry & zero clearance fireplaces location inches millimeters a insert side to combustible side wall 6 152 b insert top to max. 2-1/4 inch face trim 0 0 c insert side to max. 2-1/4 inch face trim 0 0 location inches millimeters f r...

  • Page 10: Warning

    10 7036-188e may 5, 2015 mt vernon ae insert mark area of floor to cut starter hole use 2 x 4 from insert packaging to support insert g. Installation into a factory-built fireplace the following modifi cations are permissible: • removal of damper or locked in open position • removal of smoke shelf o...

  • Page 11

    May 5, 2015 7036-188e 11 mt vernon ae insert keep sharp edge of metal floor away from power cord leveling leg figure 11.1. Place the insert into the facto- ry-built fi rebox. Ensure that the power cord can not be damaged by the sharp metal edge. You may need to cut out a notch to accommodate the cor...

  • Page 12

    12 7036-188e may 5, 2015 mt vernon ae insert 4 vent information a. Venting termination minimum requirements j or k x v m i h a v g b v v a b v f v c b b e l v d v electrical service v n v n v n n v inside corner fixed closed open open fixed closed v x g g termination cap air supply inlet gas meter r...

  • Page 13

    May 5, 2015 7036-188e 13 mt vernon ae insert b. Avoiding smoke and odors negative pressure, shut-down and electrical power failure to reduce the probability of back-drafting or burn-back in the pellet appliance during power failure or shut down con- ditions, it must be able to draft naturally withou...

  • Page 14

    14 7036-188e may 5, 2015 mt vernon ae insert c. Negative pressure negative pressure results from the imbalance of air avail- able for the appliance to operate properly. It can be strongest in lower levels of the house. Causes include: • exhaust fans (kitchen, bath, etc.) • range hoods • combustion a...

  • Page 15

    May 5, 2015 7036-188e 15 mt vernon ae insert f. Equivalent feet of pipe the table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Figure 15.1. 2 ft. 2 ft. 3 ft. 2 ft. Example of 3 elbow-rear vent termination calculation pellet venting co...

  • Page 16

    16 7036-188e may 5, 2015 mt vernon ae insert 5 venting systems note: in canada, where passage through a wall or partition of com- bustible construction is desired, the installation shall conform to can/csa-b365. Figure 16.1 fire risk. Inspection of chimney: • masonry chimney must be in good conditio...

  • Page 17

    May 5, 2015 7036-188e 17 mt vernon ae insert note: check clearances carefully for this type of instal- lation to ensure adequate room for outside air venting. Check building codes prior to installation. • installation must comply with local, regional, state and national codes and regulations. • cons...

  • Page 18

    18 7036-188e may 5, 2015 mt vernon ae insert 6 appliance set-up a. Leveling system b. Outside air kit instructions included in kit: 2 wire ties, 1 collar assembly, 1 termination cap assembly, 1 trim ring, fasteners. Note: 3 inch (76mm) aluminum flex pipe not included. Tools needed: phillips head scr...

  • Page 19

    May 5, 2015 7036-188e 19 mt vernon ae insert c. Hearth support figure 19.1 figure 19.4 - shown with cast panel set basic cast attach trim to base from underneath attach trim to insert from inside insert. Install front trim last, corner overlap side trim pieces 5 in 3 in 5 inch high set 3 inch high s...

  • Page 20

    20 7036-188e may 5, 2015 mt vernon ae insert e. Surround and trim set - cast figure 20.5 figure 20.1 figure 20.4 figure 20.2- completed view f. Surround & trim set, basic back of top surround back of side surround screws included in surround & trim kit: (2) corner brackets and set screws; (1) trim s...

  • Page 21

    May 5, 2015 7036-188e 21 mt vernon ae insert caution logs are fragile. Use extreme care when handling or cleaning logs. Notice: due to the abrasive nature of a pellet appliance fi re, the logs are not covered under warranty. Any placement variation other than shown here can cause excessive heat and ...

  • Page 22

    22 7036-188e may 5, 2015 mt vernon ae insert 7 mobile home installation you must use a quadra-fire outside air kit for installation in a mobile home. 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted whil...

  • Page 23: Mt Vernon Insert-Ae

    May 5, 2015 7036-188e 23 mt vernon ae insert service parts r mt vernon insert-ae beginning manufacturing date: sept. 2006 ending manufacturing date: active important: this is dated information. Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to...

  • Page 24

    24 7036-188e may 5, 2015 do not discard this manual caution • important operating and maintenance instruc- tions included. • leave this manual with party responsible for use and operation. • read, understand and follow these instruc- tions for safe installa- tion and operation. Do not discard contac...