Quadra-Fire MTVERNINSAE-CSB Installation Manual

Manual is about: MT VERNON PELLET INSERT ADVANCED ENERGY

Summary of MTVERNINSAE-CSB

  • Page 1

    1 7036-188j october 3, 2017 mt vernon pellet insert advanced energy (ae) model(s): mtverninsae-mbk mtverninsae-pmh mtverninsae-csb installation manual installation & appliance set-up installer: leave this manual with party responsible for use and operation. Owner: retain this manual for future refer...

  • Page 2

    2 7036-188j october 3, 2017 mt vernon ae insert table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided may result in death or serious injury. • caution...

  • Page 3

    October 3, 2017 7036-188j 3 mt vernon ae insert model mt. Vernon pellet insert ae laboratory omni test laboratories, inc. Report no. 061-s-69-6 type solid fuel room appliance/pellet type insert standard astm e1509-04, ulc s628-93 and ulc/ord-c1482-m1990 room appli- ance pellet fuel burning type and ...

  • Page 4: Install Guide

    4 7036-188j october 3, 2017 mt vernon ae insert install guide 2 getting started marginal location: • below peak location not recommended: • not the highest point of the roof • wind loading possible multi-level roofs windward leeward recommended: outside air intake on windward side not recommended: o...

  • Page 5

    October 3, 2017 7036-188j 5 mt vernon ae insert hearth & home technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: • installation & use of any damaged appliance. • modification of the appliance. • installation other than as instructed by hearth & ...

  • Page 6

    6 7036-188j october 3, 2017 mt vernon ae insert e. Install checklist appliance install appliance is leveled and connector is secured to appliance. Hearth extension size/height decided. Outside air kit installed. Floor protection requirements have been met. If appliance is connected to a masonry chim...

  • Page 7

    October 3, 2017 7036-188j 7 mt vernon ae insert figure 7.2 - front view with cast panel set figure 7.1 - top view with cast panel set figure 7.4 - top view with basic surround panel set figure 7.5 - front view with basic surround set 36-5/8 [ 932] 15 [380] 13-1/8 [333] 12-7/8 [327] 32 [814] 23-7/8 [...

  • Page 8

    8 7036-188j october 3, 2017 mt vernon ae insert note: • illustrations reflect typical installations and are for design purposes only. • i llustrations/diagrams are not drawn to scale. • actual installation may vary due to individual design preference. B. Clearances to combustibles (ul and ulc) fire ...

  • Page 9

    October 3, 2017 7036-188j 9 mt vernon ae insert c. Minimum opening for masonry & zero clearance fireplaces figure 9.3 figure 9.1 firepla ce fr ont surf a ce usa 15-1/8 canada 15-1/8 (537mm) 41-3/4 1060mm 12in max * mantel if employing a hearth extension, any parts or materials used in construction m...

  • Page 10: Warning

    10 7036-188j october 3, 2017 mt vernon ae insert mark area of floor to cut starter hole d. Installation into a factory-built fireplace the following modifications are permissible: • removal of damper or locked in open position • removal of smoke shelf or baffle • removal of ember catches • removal o...

  • Page 11

    October 3, 2017 7036-188j 11 mt vernon ae insert keep sharp edge of metal floor away from power cord leveling leg figure 11.2. Place the insert into the facto- ry-built firebox. Ensure that the power cord can not be damaged by the sharp metal edge. You may need to cut out a notch to accommodate the ...

  • Page 12

    12 7036-188j october 3, 2017 mt vernon ae insert 4 vent information a. Venting termination minimum requirements j or k x v m i h a v g b v v a b v f v c b b e l v d v electrical service v n v n v n n v inside corner fixed closed open open fixed closed v x g g termination cap air supply inlet gas met...

  • Page 13

    October 3, 2017 7036-188j 13 mt vernon ae insert b. Avoiding smoke and odors negative pressure, shut-down and electrical power failure to reduce the probability of back-drafting or burn-back in the pellet appliance during power failure or shut down con- ditions, it must be able to draft naturally wi...

  • Page 14

    14 7036-188j october 3, 2017 mt vernon ae insert c. Negative pressure negative pressure results from the imbalance of air avail- able for the appliance to operate properly. It can be strongest in lower levels of the house. Causes include: • exhaust fans (kitchen, bath, etc.) • range hoods • combusti...

  • Page 15

    October 3, 2017 7036-188j 15 mt vernon ae insert f. Equivalent feet of pipe the table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Figure 15.1. 2 ft. 2 ft. 3 ft. 2 ft. Example of 3 elbow-rear vent termination calculation pellet ventin...

  • Page 16

    16 7036-188j october 3, 2017 mt vernon ae insert 5 venting systems note: in canada, where passage through a wall or partition of com- bustible construction is desired, the installation shall conform to can/csa-b365. Figure 16.1 fire risk. Inspection of chimney: • masonry chimney must be in good cond...

  • Page 17

    October 3, 2017 7036-188j 17 mt vernon ae insert note: check clearances carefully for this type of instal- lation to ensure adequate room for outside air venting. Check building codes prior to installation. • installation must comply with local, regional, state and national codes and regulations. • ...

  • Page 18

    18 7036-188j october 3, 2017 mt vernon ae insert 6 appliance set-up a. Leveling system b. Outside air kit instructions included in kit: 2 wire ties, 1 collar assembly, 1 termination cap assembly, 1 trim ring, fasteners. Note: 3 inch (76mm) aluminum flex pipe not included. Tools needed: phillips head...

  • Page 19

    October 3, 2017 7036-188j 19 mt vernon ae insert c. Hearth support figure 19.1 figure 19.4 - shown with cast panel set basic cast attach trim to base from underneath attach trim to insert from inside insert. Install front trim last, corner overlap side trim pieces 5 in 3 in 5 inch high set 3 inch hi...

  • Page 20

    20 7036-188j october 3, 2017 mt vernon ae insert e. Surround and trim set - cast figure 20.5 figure 20.1 figure 20.4 figure 20.2- completed view f. Surround & trim set, basic back of top surround back of side surround screws included in surround & trim kit: (2) corner brackets and set screws; (1) tr...

  • Page 21

    October 3, 2017 7036-188j 21 mt vernon ae insert caution logs are fragile. Use extreme care when handling or cleaning logs. Notice: due to the abrasive nature of a pellet appliance fire, the logs are not covered under warranty. Any placement variation other than shown here can cause excessive heat a...

  • Page 22

    22 7036-188j october 3, 2017 mt vernon ae insert 7 mobile home installation you must use a quadra-fire outside air kit for installation in a mobile home. 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted ...

  • Page 23: Mt Vernon Insert-Ae

    October 3, 2017 7036-188j 23 mt vernon ae insert service parts r mt vernon insert-ae beginning manufacturing date: sept. 2006 ending manufacturing date: active important: this is dated information. Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directl...

  • Page 24

    24 7036-188j october 3, 2017 contact information hearth & home technologies 352 mountain house road halifax, pa 17032 division of hni industries please contact your quadra-fire dealer with any questions or concerns. For the number of your nearest quadra-fire dealer log onto www.Quadrafire.Com do not...