  • Page 1

    R www.Quadrafire.Com 7001-142d september 1, 2008 santa fe pellet stove owner’s manual installation and operation santafe-b1 model: hot! Do not touch . Severe burns may result. Clothing ignition may result. Warning • keep children away. • carefully supervise children in same room as appliance. • aler...

  • Page 2: Caution

    Page 2 7001-142d september 1, 2008 santa fe pellet stove r r r hearth & home technologies welcomes you to our tradi- tion of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durabil- ity, and performance. This commitment begins with our research of th...

  • Page 3

    R r r september 1, 2008 7001-142d page santa fe pellet stove section 1: listing and code approvals a. Appliance certifications ......................4 b. Mobile home approved ......................4 c. Glass specifications ............................4 d. Electrical rating .............................

  • Page 4

    Page 4 7001-142d september 1, 2008 santa fe pellet stove r r r 1 listing and code approvals a. Appliance certification c. Glass specifications e. Btu & efficiency specifications this appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer f...

  • Page 5

    R r r september 1, 2008 7001-142d page 5 santa fe pellet stove 2 getting started a. Design, installation & location considerations 1. Appliance location consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is ...

  • Page 6

    Page 6 7001-142d september 1, 2008 santa fe pellet stove r r r d. Inspect appliance & components and pre-use check list reciprocating saw channel locks hammer phillips screwdriver tape meausre plumb line level framing material hi-temp caulking material gloves safety glasses framing square electric d...

  • Page 7

    R r r september 1, 2008 7001-142d page 7 santa fe pellet stove 3 dimensions and clearances a. Appliance dimensions figure 7.2- front view figure 7.1 - top view figure 7.3 -side view figure 7.4 - side view with top vent adapter 25-7/16 in. (646 mm) 12-11/16 in . (322mm) 21-3/16 in. (538mm) 27-/4 in. ...

  • Page 8

    Page 8 7001-142d september 1, 2008 santa fe pellet stove r r r straight back against wall inches millimeters a back wall to appliance 2 51 b side wall to appliance 6 152 corner installation inches millimeters c walls to appliance 2 51 vertical installation inches millimeters d back wall to flue pipe...

  • Page 9

    R r r september 1, 2008 7001-142d page 9 santa fe pellet stove *l exception for horizontal installations: usa installations : if optional cast base is installed use a non-combustible floor protector extending under unit and to the sides, front and back of unit as shown in floor protection diagram. M...

  • Page 10

    Page 10 7001-142d september 1, 2008 santa fe pellet stove r r r do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such...

  • Page 11

    R r r september 1, 2008 7001-142d page 11 santa fe pellet stove improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appli- ance. For assistance or additional information consult a qualif...

  • Page 12

    Page 12 7001-142d september 1, 2008 santa fe pellet stove r r r 5 venting systems note: • illustrations reflect typical installations and are for design purposes only. • illustrations/diagrams are not drawn to scale. • actual installation may vary due to individual design preference. A. Alcove figur...

  • Page 13: 45 Degree

    R r r september 1, 2008 7001-142d page 1 santa fe pellet stove b. Through the wall horizontal termination cap must be a minimum of 12 inches. (05mm) from the wall. Approved for mobile home instal- lations. Must use or 4 inch (76-102mm) “l” or “pl” listed pellet venting or listed double wall pipe and...

  • Page 14

    Page 14 7001-142d september 1, 2008 santa fe pellet stove r r r we recommend a minimum of 60 in. (1524mm) vertical, however above the eave is preferred. Both installations are approved for mobile home installations. Must use or 4 inch (76 to 102mm) “l” or “pl” listed pellet venting or listed double ...

  • Page 15

    R r r september 1, 2008 7001-142d page 15 santa fe pellet stove fire risk inspection of chimney: • masonry chimney must be in good condition. • meets minimum standard of nfpa 211 • factory-built chimney must be 6 inch (152mm) ul10 ht. Warning e. Masonry f. Alternate masonry non-combustible hearth pa...

  • Page 16

    Page 16 7001-142d september 1, 2008 santa fe pellet stove r r r 6 mobile home 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes sm...

  • Page 17

    R r r september 1, 2008 7001-142d page 17 santa fe pellet stove 7 appliance set-up a. Outside air kit instructions flex hose hose clamp collar assembly trim ring termination cap assembly hose clamp air intake channel parts included in kit: 1 piece of 2 inch x foot flex hose, 2 hose clamps, 1 collar ...

  • Page 18

    Page 18 7001-142d september 1, 2008 santa fe pellet stove r r r 3 to 3 inch top vent adapter 3 to 6 inch top vent offset adapter 1. Put a layer of high temperature silicone on the inch (76mm) exhaust outlet. Figure 18.1 2. Slide the top vent adapter onto the rear exhaust outlet and adjust the assemb...

  • Page 19

    R r r september 1, 2008 7001-142d page 19 santa fe pellet stove d. Optional log set placement instructions figure 19.1 4 piece log set installation optional top log figure 19.2 figure 19.3 caution logs are fragile. Use extreme care when handling or cleaning logs. Note: due to the abrasive nature of ...

  • Page 20

    Page 20 7001-142d september 1, 2008 santa fe pellet stove r r r e. Optional gold or nickel grille & trim ring 1 . While holding door to face, remove 2 screws from grille and remove existing grille. Figure 20.1. 2. Install new grille using screws removed in step 1. Ensure that screws are inserted thr...

  • Page 21

    R r r september 1, 2008 7001-142d page 21 santa fe pellet stove 1 . A 12 volt ac thermostat is required to operate this pellet appliance. You may use the included wall mount thermo- stat or purchase an optional programmable thermostat or remote control. It is equipped with an adjustable heat anticip...

  • Page 22

    Page 22 7001-142d september 1, 2008 santa fe pellet stove r r r 8 operating instructions a. Fuel size and material 1. Wood pellets fuel pellets are made from sawdust or wood by-products. If the source material is hardwood, they can have a higher mineral content, creating more ash. Fuels containing b...

  • Page 23

    R r r september 1, 2008 7001-142d page 2 santa fe pellet stove figure 23.1 e. Fire characteristics a properly adjusted fire with the heat output control switch set on “high” has a short active flame pattern that extends out of the firepot approximately 4 inches (102mm). If the fire has tall flames w...

  • Page 24

    Page 24 7001-142d september 1, 2008 santa fe pellet stove r r r g. Iginition cycles 1. During each ignition cycle, it is normal to see some smoke in the firebox. The smoke will stop once the fire starts. 2. The convection blower will automatically turn on after your appliance has been burning for ap...

  • Page 25

    R r r september 1, 2008 7001-142d page 25 santa fe pellet stove 9 troubleshooting with proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the d...

  • Page 26

    Page 26 7001-142d september 1, 2008 santa fe pellet stove r r r symptom possible cause corrective action slow or smoky start-up (cont’d) dirty exhaust and/or venting system. Check for ash build up in unit, includ- ing behind rear panels, firebox, heat exchanger, exhaust blower and venting. Feed syst...

  • Page 27

    R r r september 1, 2008 7001-142d page 27 santa fe pellet stove symptoms possible cause corrective action convection blower fails to start. #1 snap disc defective. Blower not plugged in. Blower is defective. Control box is defective. Replace snap disc. Check that blower is plugged into wire har- nes...

  • Page 28

    Page 28 7001-142d september 1, 2008 santa fe pellet stove r r r 10 maintaining & servicing your appliance c. General maintenance 1. Types of fuel depending on the type of fuel you are burning will dictate how often you have to clean your firepot. If the fuel you are burning has a high dirt or ash co...

  • Page 29: Warning

    R r r september 1, 2008 7001-142d page 29 santa fe pellet stove warning • the cleaning slide plates must be fully closed when appliance is operating. Hot pellets may fall into ashpan and start a fire. Fire hazard. 2. Cleaning firepot with cleaning rod & firepot scraper • frequency: daily or more oft...

  • Page 30

    Page 0 7001-142d september 1, 2008 santa fe pellet stove r r r figure 30.2 vacuum inside exhaust venting cleaning rods 10 heat exchanger tubes the amount of ash buildup in the firepot will be a good guide to determine how often you should clean the heat exchangers. A. Allow the appliance to complete...

  • Page 31

    R r r september 1, 2008 7001-142d page 1 santa fe pellet stove 11. Cleaning the glass • frequency: when clear view of the firepot becomes obscure • by: homeowner a. Appliance must be completely cool before cleaning glass. B. Use a damp paper towel or any non-abrasive glass cleaner. Wipe off with dry...

  • Page 32

    Page 2 7001-142d september 1, 2008 santa fe pellet stove r r r b. High ash fuel content maintenance • frequency: as needed • by: homeowner correct flame size, yellow/white in color correct figure 32.3 ash build up in firebox pellets back up in feed tube firepot overfills tall, lazy flame, orange in ...

  • Page 33

    R r r september 1, 2008 7001-142d page santa fe pellet stove 1. Convection blower replacement a. Turn down the thermostat, let appliance completely cool and then unplug appliance before servicing. B. The convection blower is located on the floor at the rear of the appliance. C. Remove the right lowe...

  • Page 34

    Page 4 7001-142d september 1, 2008 santa fe pellet stove r r r note : combustion blower gasket is also required. Sold separately under part number 240-0812. A. Turn down the thermostat, let appliance completely cool and then unplug appliance before servicing. B. Remove the 2 side curtains by removin...

  • Page 35

    R r r september 1, 2008 7001-142d page 5 santa fe pellet stove d. Igniter replacement e. Baffle & brick removal 1. Shut down the appliance by turning down the thermostat and let the appliance completely cool down. After the appliance has cooled down, unplug it and remove the ash drawer. 2. The wire ...

  • Page 36

    Page 6 7001-142d september 1, 2008 santa fe pellet stove r r r f. Baffle & brick replacement right brick installed brick is flush against back wall brick in front of clip and notches exposed lift brick, pull forward at an angle and drop down into notches opening at left side of baffle tabs do not re...

  • Page 37

    R r r september 1, 2008 7001-142d page 7 santa fe pellet stove g. Glass replacement • glass is 5mm thick high temperature heat- resistant ceramic glass. • do not replace with any other material. • alternate material may shatter and cause injury. Warning figure 37.1 1. Open the face and remove door f...

  • Page 38

    Page 8 7001-142d september 1, 2008 santa fe pellet stove r r r 11 reference materials 7. Heat exchangers the heat exchangers transfer hot air from the exhaust system into convecton air. Remove the stainless steel top baffle to access the heat exchangers. There are 2 clean out rods located under the ...

  • Page 39

    R r r september 1, 2008 7001-142d page 9 santa fe pellet stove 16. Snap disc #1 (convection blower) 110°f snap disc #1 is located on the right side of the appliance on the bottom of the heat exchanger box. There are 2 purple wires connected to it. This snap disc turns the convection blower on and of...

  • Page 40

    Page 40 7001-142d september 1, 2008 santa fe pellet stove r r r b. Component locations red call light fuse control box vacuum switch junction box high med low heat output switch reset button reset butto n convection blower exhaust blower button cleaning rods 10 heat exchanger tubes terminal block ce...

  • Page 41

    R r r september 1, 2008 7001-142d page 41 santa fe pellet stove figure 41.1 - door, face, glass & door latch assembly 2 56 5 5 6 7 55 figure 41.2 - firepot assembly c. Exploded views 1 2 0 5 6 7 57 58 glass size 17-1/4” 1 1-5/8” item description part number 1 door latch assembly 7001-042 2 rope reta...

  • Page 42

    Page 42 7001-142d september 1, 2008 santa fe pellet stove r r r figure 42.1 39 31 30 32 33 34 35 36 37 38 40 41 42 43 44 45 46 47 49 50 51 52 53 54 55 56 57 48 58 59 item nbr description item nbr description item nbr description 30 door assembly 40 pedestal back (not sellable) 50 hopper lid 31 ash c...

  • Page 43

    R r r september 1, 2008 7001-142d page 4 santa fe pellet stove d. Service parts and accessories item # service parts description part nbr ash catcher 7001-116 ash drawer assembly 7001-004 5 baffle assembly uk-0kpel 9 blower, convection 812-4900 41 blower, exhaust with housing 812-4400 brick, center ...

  • Page 44

    Page 44 7001-142d september 1, 2008 santa fe pellet stove r r r accessory description part number grille, louver, gold lvgrl-sf-gd grille, louver, nickel lvgrl-sf-nl log set, 4 pieces 811-0852 log, top, 1 piece (to cover firepot) 811-0900 outside air kit 811-0872 pedestal base, cast iron 811-0840 re...

  • Page 45

    R r r september 1, 2008 7001-142d page 45 santa fe pellet stove date of service performed by description of service e. Service and maintenance log.

  • Page 46

    Page 46 7001-142d september 1, 2008 santa fe pellet stove r r r f. Warranty policy hearth & home technologies limited warranty hearth & home technologies (“hht”) and its respective brands extends the following warranty for hht gas, wood, pellet and electric appliances purchased from an authorized hh...

  • Page 47

    R r r september 1, 2008 7001-142d page 47 santa fe pellet stove noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this noise are not covered by this warranty. Hht’s obligation under this warranty does not extend to damages resulting f...

  • Page 48: Your Records For Model:

    R hearth & home technologies 1445 north highway colville, wa 99114 division of hni industries 7001-142d september 1, 2008 page 48 contact information: please contact your quadra-fire dealer with any questions or concerns. For the number of your nearest quadra-fire dealer logo onto www.Quadrafire.Com...