Quadra-Fire SANTAFE-B1 Owner's Manual

Other manuals for SANTAFE-B1: Owner's Manual
Manual is about: Hearth & Home Technologies Santa Fe Pellet Stove Owner's Manual Installation and Operation

Summary of SANTAFE-B1

  • Page 1

    R www.Quadrafire.Com 7001-142c november 2, 2005 santa fe pellet stove owner’s manual installation and operation santafe-b1 model: hot! Do not touch. Severe burns may result. Clothing ignition may result. Warning • keep children away. • carefully supervise children in same room as appliance. • alert c...

  • Page 2: Caution

    Page 2 7001-142c november 2, 2005 santa fe pellet stove r r r hearth & home technologies welcomes you to our tradi- tion of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durabil- ity, and performance. This commitment begins with our research of the...

  • Page 3

    Rr r november 2, 2005 7001-142c page 3 santa fe pellet stove section 1: listing and code approvals a. Appliance certifications ......................4 b. Mobile home approved ......................4 c. Glass specifications ............................4 d. Electrical rating ...............................

  • Page 4

    Page 4 7001-142c november 2, 2005 santa fe pellet stove r r r 1 listing and code approvals model: santa fe pellet stove laboratory: omni test laboratories, inc. Report no. 061-s-53-2 type: solid fuel room heater/pellet type standard: astm e1509 and ulc/ord-c1482 room heater pellet fuel burning type ...

  • Page 5

    Rr r november 2, 2005 7001-142c page 5 santa fe pellet stove 2 getting started a. Design, installation & location considerations 1. Appliance location consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a go...

  • Page 6

    Page 6 7001-142c november 2, 2005 santa fe pellet stove r r r e. Inspect appliance & components and pre-use check list reciprocating saw channel locks hammer phillips screwdriver tape meausre plumb line level framing material hi-temp caulking material gloves safety glasses framing square electric dr...

  • Page 7

    Rr r november 2, 2005 7001-142c page 7 santa fe pellet stove 3 dimensions and clearances a. Appliance dimensions figure 7.2- front view figure 7.1 - top view figure 7.3 -side view figure 7.4 - side view with top vent adapter 25-7/16 in. (705 mm) 12-11/16 in . (322mm) 21-3/16 in. (538mm) cl 27-3/4 in...

  • Page 8

    Page 8 7001-142c november 2, 2005 santa fe pellet stove r r r straight back against wall inches millimeters a back wall to appliance 2 51 b side wall to appliance 6 152 corner installation inches millimeters c walls to appliance 2 51 vertical installation inches millimeters d back wall to flue pipe ...

  • Page 9

    Rr r november 2, 2005 7001-142c page 9 santa fe pellet stove *l exception for horizontal installations: usa installations: if optional cast base is installed use a noncombustible floor protector extending under unit and to the sides, front and back of unit as shown in floor protection diagram. Measur...

  • Page 10

    Page 10 7001-142c november 2, 2005 santa fe pellet stove r r r do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such ...

  • Page 11

    Rr r november 2, 2005 7001-142c page 11 santa fe pellet stove improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appli- ance. For assistance or additional information consult a qualified...

  • Page 12

    Page 12 7001-142c november 2, 2005 santa fe pellet stove r r r 5 venting systems note: • illustrations reflect typical installations and are for design purposes only. • illustrations/diagrams are not drawn to scale. • actual installation may vary due to individual design preference. A. Alcove figure ...

  • Page 13: 45 Degree

    Rr r november 2, 2005 7001-142c page 13 santa fe pellet stove 12 in. (305mm) minimum noncombustible hearth pad wall thimble horizontal termination cap 2 in. (51mm) minimum 6 in. (152mm) minimum from glass straight out b. Through the wall horizontal termination cap must be a minimum of 12 inches. (30...

  • Page 14

    Page 14 7001-142c november 2, 2005 santa fe pellet stove r r r we recommend a minimum of 60 in. (1524mm) vertical, however above the eave is preferred. Both installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “l” or “pl” listed pellet venting or listed double...

  • Page 15

    Rr r november 2, 2005 7001-142c page 15 santa fe pellet stove fire hazard inspection of chimney: • masonry chimney must be in good condition. • meets minimum standard of nfpa 211 • factory-built chimney must be 6 inch (152mm) ul103 ht. Warning e. Masonry f. Alternate masonry noncombustible hearth pa...

  • Page 16

    Page 16 7001-142c november 2, 2005 santa fe pellet stove r r r 6 mobile home 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes smo...

  • Page 17

    Rr r november 2, 2005 7001-142c page 17 santa fe pellet stove 7 appliance set-up a. Outside air kit instructions flex hose hose clamp collar assembly trim ring termination cap assembly hose clamp parts included in kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose clamps, 1 collar assembly, 1 terminat...

  • Page 18

    Page 18 7001-142c november 2, 2005 santa fe pellet stove r r r 3 to 3 inch top vent adapter 3 to 6 inch top vent offset adapter 1. Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet. Figure 18.1 2. Slide the top vent adapter onto the rear exhaust outlet and adjust the assem...

  • Page 19

    Rr r november 2, 2005 7001-142c page 19 santa fe pellet stove d. Optional log set placement instructions figure 19.1 4 piece log set installation optional top log figure 19.2 figure 19.3 caution logs are fragile. Use extreme care when handling or cleaning logs. Note: due to the abrasive nature of a ...

  • Page 20

    Page 20 7001-142c november 2, 2005 santa fe pellet stove r r r e. Optional gold or nickel grille & trim ring 1 . While holding door to face, remove 2 screws from grille and remove existing grille. Figure 1. 2. Install new grille using screws removed in step 1. Ensure that screws are inserted through...

  • Page 21

    Rr r november 2, 2005 7001-142c page 21 santa fe pellet stove 1 . A 12 volt ac thermostat is required to operate this pellet appliance. You may use the included wall mount thermo- stat or purchase an optional programmable thermostat or remote control. It is equipped with an adjustable heat anticipat...

  • Page 22

    Page 22 7001-142c november 2, 2005 santa fe pellet stove r r r 8 operating instructions a. Fuel size and material 1. Wood pellets fuel pellets are made from sawdust or wood by-products. If the source material is hardwood, they can have a higher mineral content, creating more ash. Fuels containing ba...

  • Page 23

    Rr r november 2, 2005 7001-142c page 23 santa fe pellet stove figure 23.1 e. Fire characteristics a properly adjusted fire with the heat output control switch set on “high” has a short active flame pattern that extends out of the firepot approximately 4 inches (102mm). If the fire has tall flames with bl...

  • Page 24

    Page 24 7001-142c november 2, 2005 santa fe pellet stove r r r g. Iginition cycles 1. During each ignition cycle, it is normal to see some smoke in the firebox. The smoke will stop once the fire starts. 2. The convection blower will automatically turn on after your appliance has been burning for appro...

  • Page 25

    Rr r november 2, 2005 7001-142c page 25 santa fe pellet stove 9 troubleshooting with proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diag...

  • Page 26

    Page 26 7001-142c november 2, 2005 santa fe pellet stove r r r symptom possible cause corrective action slow or smoky start-up (cont’d) dirty exhaust and/or venting system. Check for ash build up in unit, includ- ing behind rear panels, firebox, heat exchanger, exhaust blower and venting. Feed system...

  • Page 27

    Rr r november 2, 2005 7001-142c page 27 santa fe pellet stove symptoms possible cause corrective action convection blower fails to start. #1 snap disc defective. Blower not plugged in. Blower is defective. Control box is defective. Replace snap disc. Check that blower is plugged into wire har- ness....

  • Page 28

    Page 28 7001-142c november 2, 2005 santa fe pellet stove r r r 10 maintaining & servicing your appliance shock hazard . • unplug appliiance before servicing or maintaining appliance caution figure 26.1 - large clinker 3. Cleaning ash drawer • frequency: as needed • by: homeowner • task: locate the a...

  • Page 29

    Rr r november 2, 2005 7001-142c page 29 santa fe pellet stove 6. Disposal of ashes • frequency: as needed • by: homeowner • task: ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away f...

  • Page 30

    Page 30 7001-142c november 2, 2005 santa fe pellet stove r r r figure 30.1 14. Cleaning the top vent adapter a. The appliance must be in complete shutdown and the exhaust blower should be off. Allow the appliance to completely cool down. B. Open the clean out cover. See figure 301. C. Sweep out any ...

  • Page 31

    Rr r november 2, 2005 7001-142c page 31 santa fe pellet stove b. High ash fuel content maintenance • frequency: as needed • by: homeowner • task: poor quality pellet fuel, or lack of maintenance, can create conditions that make the firepot fill quickly with ashes and clinkers. This condition makes the...

  • Page 32

    Page 32 7001-142c november 2, 2005 santa fe pellet stove r r r 1. Convection blower replacement a. Turn down the thermostat, let appliance completely cool and then unplug appliance before servicing. B. The convection blower is located on the floor at the rear of the appliance. C. Remove the right low...

  • Page 33

    Rr r november 2, 2005 7001-142c page 33 santa fe pellet stove d. Igniter replacement e. Baffle & brick removal a. Shut down the appliance by turning down the thermostat and let the appliance completely cool down . After the appliance has cooled down, unplug it and remove the ash drawer. B. The wire l...

  • Page 34

    Page 34 7001-142c november 2, 2005 santa fe pellet stove r r r f. Baffle & brick replacement right brick installed brick is flush against back wall brick in front of clip and notches exposed lift brick, pull forward at an angle and drop down into notches opening at left side of baffle tabs do not rem...

  • Page 35

    Rr r november 2, 2005 7001-142c page 35 santa fe pellet stove g. Glass replacement • glass is 5mm thick high temperature heat- resistant ceramic glass. • do not replace with any other material. • alternate material may shatter and cause injury. Warning figure 35.1 • frequency: as needed • by: qualifi...

  • Page 36

    Page 36 7001-142c november 2, 2005 santa fe pellet stove r r r 11 reference materials 7. Heat exchangers the heat exchangers transfer hot air from the exhaust system into convecton air. Remove the stainless steel top baffle to access the heat exchangers. There are 2 clean out rods located under the h...

  • Page 37

    Rr r november 2, 2005 7001-142c page 37 santa fe pellet stove snap disc #1 is located on the right side of the appliance on the bottom of the heat exchanger box. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap...

  • Page 38

    Page 38 7001-142c november 2, 2005 santa fe pellet stove r r r b. Component locations red call light fuse control box vacuum switch junction box high med low heat output switch reset button reset butto n convection blower exhaust blower button cleaning rods heat exchanger tubes terminal block center...

  • Page 39

    Rr r november 2, 2005 7001-142c page 39 santa fe pellet stove figure 39.1 - door, face, glass & door latch assembly item description part number 1 door latch assembly 7001-042 2 rope retainer rod 7001-192 3 glass assembly 7001-038 30 door assembly 7001-035 5 hinge, female 450-2910 6 screw, 10-32 x 1...

  • Page 40

    Page 40 7001-142c november 2, 2005 santa fe pellet stove r r r beg. Manufacture date: august, 2003 figure 40.1 39 31 30 32 33 34 35 36 37 38 40 41 42 43 44 45 46 47 49 50 51 52 53 54 55 56 57 48 58 59 item nbr description item nbr description item nbr description 30 door assembly 40 pedestal back 50...

  • Page 41

    Rr r november 2, 2005 7001-142c page 41 santa fe pellet stove important: this is dated information. The most current information is located on the quadra-fire web site at www.Quadrafire.Com. When ordering, supply serial and model numbers to ensure correct service parts. D. Service parts and accessori...

  • Page 42

    Page 42 7001-142c november 2, 2005 santa fe pellet stove r r r acccesory description part number grille, louver, gold lvgrl-sf-gd grille, louver, nickel lvgrl-sf-nl log set, 4 pieces 811-0851 log, top, 1 piece (to cover firepot) 811-0900 outside air kit 811-0872 pedestal base, cast iron 811-0840 rear...

  • Page 43: Lifetime Warranty

    Rr r november 2, 2005 7001-142c page 43 santa fe pellet stove lifetime warranty g. Warranty policy limited lifetime warranty the hearth & home technologies limited lifetime warranty guarantees that the following components will work as designed for the lifetime of the stove or hearth & home technolo...

  • Page 44: Your Records For Model:

    R hearth & home technologies 1445 north highway colville, wa 99114 division of hni industries www.Quadrafire.Com 7001-142c november 2, 2005 page 44 contact information: please contact your quadra-fire dealer with any questions or concerns. For the number of your nearest quadra-fire dealer please call...