Press
Set
G again to set the parameters for the mode selected. For
example, power (1/64 to 1/1) for Man, F# for Auto, etc. There are no set-
tings for TTL or OFF modes.
If a QTTL adapter is connected to
any
of the Qflash 4d’s, then QTTL mode
will be available for
all
of the Qflashes. The Control Qflash will display the
fill/flash ratio set on the QTTL adapter. To change the ratio, turn the
R Fill
dial on the QTTL adapter. The fill ratio will be effective for all Qflashes con-
nected.
Note: Some cameras have their own flash compensation ( +/-). Use
either
the camera’s flash compensation, or Qflash’s,
but not both.
Press
Set
G again and the film speed (ISO) blinks. Make the adjustment
with the
Up/Down
J L buttons. Note that in QTTL mode the film speed is
controlled by the camera and cannot be changed here.
7.1.3 Changing the Remote flash settings from the Control flash
Press
Set
G until “C”, “R1” or “R2” blinks in the display. Use the
Up/Down
J L buttons until “R1” or “R2” blinks.
Press
Set
G again and the mode of R1 or R2 will blink. Use the
Up/Down
J L buttons to change the mode of the Remote. The modes
available are Man, Auto, TTL, and OFF. If the Control Qflash is in Auto
mode then Linked mode replaces TTL mode.
Press
Set
G again to set the parameters for the mode selected. The
parameters to set depend on the mode. Linked mode (available when the
Control Qflash is in Auto or Auto Fill Mode) sets a Linked ratio for Remotes
1 & 2. If both R1 and R2 are set to Linked mode, the ratio will appear next
to R1 only, although this ratio is for both flashes.
7.1.4 Changing the designation for Remote 1 and Remote 2
You may wish to change which Remote flash is designated R1 and which
is R2. This can only be done at one of the Remote Qflashes.
Press the
Set
G button on a Remote flash. “Remote” on the display will
blink. Use the
Up/Down
J L buttons to change from R1 to R2, or vice
versa. As you change this Remote flash, the second Remote Qflash (if
connected) will change automatically. Each Remote Qflash will pick up its
settings (R1 or R2) from the Control Qflash.
7.2 Multiple Qflash Operation with models T, X, T2, X2, T2d, X2d, T4d,
and X4d
Qflash models may be mixed in multiple flash setups. The Wired Control
features of Section 7.1 will not be available, however, synchronization, fill
ratio, and TTL control can be achieved in various setups discussed below.
The position of different Qflash models is not important, and the models
may exchange positions in the examples shown. The examples below
illustrate Qflash T- model types, although X- model types work in the same
way. You can connect any number of Qflash units together in any of the