Model 9113-0-0 Product Manual
Page 3
PM9113-0-0 Revision 2
Multiple Axis:
The 9113 provides a bridge to a single drive When an application requires multiple drives to be controlled then
each drive will have an associated 9113 with a unique IP address. An ethernet hub or switch will be required to
connect the devices.
Each 9113 in a network must have a unique IP address. The node address of the Ultra 3000 has no significance in
the network but must match the node set in the 9113. The 9113 is configured by the factory to access Ultra node
zero which is the default for a new Ultra 3000 drive. The node used by the 9113 can be modified using the Option
Setup Utility program.
Address Mapping Utility
This utility will find the File/Element number associated
with an Ultra 3000 parameter you select. The utility will
run along with RSLogix and will remain on top unless
minimized. This allows you to quickly select a parameter,
copy the associated File/Element number to the
Windows clipboard then paste the number into the
RSLogix Message Instruction setup dialog.