Quick MILL 4003 Operating Instructions Manual - page 15
Mod. 04003 / 04004
Rev. 01
13.
TERMOPID functional technical specification
1.1 PROGRAMMING SET-POINT OF TEMPERATURE
• Press the button
• When the display shows PrG, press the button
• When the display shows the setpoint, set with the buttons
and
the desired temperature value, from a
minimum of 85C° to a maximum of 105C°.
After 3 seconds from the last button pressing, the data are saved and the display shows the temperature.
1.2 PROGRAMMING ADJUSTMENT PARAMETERS
• Switch on the machine through the main switch 1 by pressing buttons
and
at the same time.
• When the display shows F.03, release the buttons.
Button
slides the parameters.
Button
enters the programming menu.
Inside the programming menu, the buttons
and
change the data; after 3 seconds from the last button
pressing, the data are saved by quitting the programming menu.
List of parameters
Parameter Display
Description
ºF
Unit of measurement: degrees Fahrenheit
F.03
ºC
Unit of measurement: degrees Celsius
P. X.X
Where X.X stands for the value of the proportional constant of the
PID control
I. X.XX
Where X.X stands for the value of the integrative constant of the
PID control
d. XX.X
Where X.X stands for the value of the derivative constant of the
PID control
F.04 X
Where X stands for the correction negative factor of the
temperature (°C)
To quit programming parameter, switch off the machine through the main switch 1.
1.3 PRESET PARAMETERS
• Switch on the machine keeping pressed button
• When the display shows PrS, release the button.
• Switch off the machine through the main switch 1.
Parameter Value
F.03 ºC
P. 3.0
I. 0.05
d. 2.0
F.04 10
(°C)
14