Quiko QK-B220 Use And Maintenance Manual - page 16
15
MD
Annex
1
Types of Risks
Evaluation Criteria and Solutions to Adopt
(Check the box corresponding to the solution adopted)
1.2
[14] Safety conditions
in case of power
failure
□
Use activation groups in accordance with regulation EN 12453 and safety
devices in accordance with regulation EN 12978.
□
Verify that the gate does not perform dangerous movements (in case of
failure of the suspension system, the gate must not fall more than 300 mm).
1.5.3
[15] Energies different
from electrical power
□
If the hydraulic activation groups are used, they must comply with
regulation EN 982; or
□
If the pneumatic activation groups are used, they must comply with
regulation EN 983.
1.2.3
1.2.4
[16] Turning the
activation group on
and off
□
Check that the activation group resumes operations safely after a power
failure or shortage and that there are no hazardous situations.
[17] Power Switch
□
Install an omnipolar switch to electrically insulate the door/gate in
accordance with the applicable regulations. This switch must be positioned and
protected from involuntary or unauthorized activations.
1.2.5
[18] Control
Coherence
□
Install the controls (for example, the key selector) so that the user is not in a
dangerous area, and check that user understands the controls (for example,
the function selectors).
□
Use the CE radio controls in accordance with R&TTE Directive (1999/5/CE)
and in accordance with the frequency permitted by the law in each country.
1.5.14
[19] Trapping hazard
□
Install an unlocking device for the activation group that allows the door to be
opened and closed with a maximum effort of 225N (for doors/gates in
residential areas) or 390N (for doors/gates in industrial or commercial areas).
Supply the user with the tools and instructions needed to perform the unlocking
operations; check that the use of the unlocking device is user-friendly and does
not create additional risks.
1.2.4
[20] Emergency Stop
□
If necessary, install an emergency stop control in accordance with regulation
EN 418.
N.B. Make sure that the emergency stop does not create additional risks by
checking the operations of the safety devices present.