Quooker Combi E Installation Manual - page 14
Connecting tank with Nordic tap
• The Quooker tank is supplied with a UK 3 pin plug and requires a standard
13 amp earthed socket.
• If the mains lead is damaged it should be replaced by the manufacturer, their
agent or a qualified technician to prevent hazard.
• The light ring on the boiling-water tap will light up to indicate when the
water is being heated inside the tank. It will also light up when the tap is
being touched to indicate that it is a boiling-water tap.
• The Q-shaped button on top of the tank is the on/off switch. Once the water
is up to temperature the light on the tank will fade in and out.
• Ensure that the tank has sufficient height clearance to avoid pinching the hose.
• Do not use any other washers or sealants than the ones supplied.
1
2
3
4
1 Connecting tank
Place the tank in position and connect the
tank hoses to the mixing valve. NOTE:
The hoses have flare fittings and should
not be fitted with any seals or washers.
Connect the tap hose to the fitting at the
top of the tank using the small washer
and size 10 and 14 spanners.
2 Electrical
connection
Connect the boiling-water tap by plug-
ging the LED cable into the hole provid-
ed at the back of the tank cover.
Connect the tank to the socket. Switch
the socket on but not the tank yet.
3 Filling tank
Open the boiling-water tap and the stop
valve on the inlet combination. Check for
leaks. Flush the tank through until the
water is clear. Black water will flow out
initially. This is Norit carbon from the
filter and completely harmless.
4 Switching on
tank
Switch on the Quooker. After the water
has heated up, the entire content of the
Quooker must be flushed out once
before use.
1
0
14
E
1