Quorum The Bristol Installation Instructions Manual - 5. Electrical Connections
5. ELECTRICAL CONNECTIONS
Fig. 9
Fig. 9a
Fig. 9b
Fig. 9c
REMEMBER
-Turn off the power!
1. Disconnect the power and remove the
existing wall plate and switch (Fig. 9)
2. Set all knobs on the dual slide wall control
in the off position. (Fig. 9a)
3. Make wire connections (Fig. 9b) and
secure with wire nuts supplied.
Black wire from fan to black wire from
speed control.
White wire from fan to white wire from the
A/C supply source.
Blue wire from fan to blue wire from light
control.
Black/White wire from speed control to
black wire from the A/C supply source.
4. If your outlet box has a ground wire (green
or bare copper) connect the wall control's
ground wire to it; otherwise connect the wall
control's ground wire directly to one of the
screws from the outlet box. (Fig. 9c)
5. Attach the wall control to the outlet
(wall) box and secure with 2 outlet box
screws (Fig. 9c).
6. Attach the wall plate over the wall
control and secure with the two screws
provided (Fig. 9c).
Wall plate
Switch
Outlet box (Wall)
Black
Black
Black
Black/White
White
White
Blue
Blue
Ground
Green
Green
120 V
supply
source
Light switch
Speed switch
Blue light switch lead
To hot black/white
Black speed control lead
Green ground lead
Wall plate
Switch
Outlet box (Wall)
Screws
Screws
*
Dash lines are 3 conductor
cable w/ground wire between
ceiling and wall outlet box.