RAD Data Communications Airmux-5000 Installation And Operation Manual

Other manuals for Airmux-5000: Installation And Operation Manual
Manual is about: High Capacity Point-to-Multipoint Wireless System

Summary of Airmux-5000

  • Page 1

    Airmux-5000 high capacity point-to-multipoint wireless system version 3.1 instal lation and operati on manual the access company.

  • Page 3: Airmux-5000

    Airmux-5000 high capacity point-to-multipoint wireless system version 3.1 installation and operation manual notice this manual contains information that is proprietary to rad data communications ltd. ("rad"). No part of this publication may be reproduced in any form whatsoever without prior written ...

  • Page 4: Limited Warranty

    Limited warranty rad warrants to distributor that the hardware in the airmux-5000 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to distributor. If, during the warranty peri...

  • Page 5: General Safety Instructions

    General safety instructions the following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety symbols this symbol may appear on the equipment or in the text. It in...

  • Page 6: Handling Energized Products

    Handling energized products general safety practices do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the off position or a fuse is blown. For dc-powered products, altho...

  • Page 7

    The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16a (20a for usa and canada). The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35a (40a for usa a...

  • Page 8

    When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The grounding and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between e...

  • Page 9: Fcc-15 User Information

    Fcc-15 user information this equipment has been tested and found to comply with the limits of the class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...

  • Page 10: Mise Au Rebut Du Produit

    Français mise au rebut du produit afin de faciliter la réutilisation, le recyclage ainsi que d'autres formes de récupération d'équipement mis au rebut dans le cadre de la protection de l'environnement, il est demandé au propriétaire de ce produit rad de ne pas mettre ce dernier au rebut en tant que ...

  • Page 11

    Français certains produits peuvent être équipés d'une diode laser. Dans de tels cas, une étiquette indiquant la classe laser ainsi que d'autres avertissements, le cas échéant, sera jointe près du transmetteur optique. Le symbole d'avertissement laser peut aussi être joint. Veuillez observer les préc...

  • Page 12

    Français connexion au courant du secteur assurez-vous que l'installation électrique est conforme à la réglementation locale. Branchez toujours la fiche de secteur à une prise murale équipée d'une borne protectrice de mise à la terre. La capacité maximale permissible en courant du circuit de distribu...

  • Page 13: Full

    Airmux-5000 hpmp user manual release 3.1.00 vi full table of contents part 1: basic installation chapter 1 introduction welcome to airmux-5000! .......................................................................... 1-1 airmux-5000 highlights .........................................................

  • Page 14

    Airmux-5000 hpmp user manual release 3.1.00 vii installing a sector using poe devices ...................................................3-10 connecting user equipment ................................................................. 3-10 aligning hsus to a hbs..........................................

  • Page 15

    Airmux-5000 hpmp user manual release 3.1.00 viii connecting an hss unit .........................................................................7-3 using a single hss unit .........................................................................7-4 using more than one hss unit ........................

  • Page 16

    Airmux-5000 hpmp user manual release 3.1.00 ix montage d'une antenne externe ........................................................... D-6 contenu du kit de montage d'une antenne externe ................................ D-6 index.

  • Page 17

    Airmux-5000 hpmp user manual release 3.1.00 x list of figures f igure 1-1 s ingle s ector b ase s tation ..............................................................1-3 f igure 1-2 s mall form factor antenna in connectorized odu .............................1-3 f igure 1-3 h igh gain integrated an...

  • Page 18

    Airmux-5000 hpmp user manual release 3.1.00 xi f igure 8-3 a rm ................................................................................................8-1 f igure 8-4 m ounting on a pole .........................................................................8-2 f igure 8-5 m ounting on a ...

  • Page 19

    Airmux-5000 hpmp user manual release 3.1.00 xii list of tables t able 4-1 pc r equirements for the a irmux m anager a pplication .........................4-1 t able 4-2 p reconfigured setup ..........................................................................4-2 t able 4-3 u ser types , default...

  • Page 20: Part 1: Basic Installation

    Airmux-5000 hpmp point to multipoint broadband wireless user manual release 3.1.00 part 1: basic installation.

  • Page 21: Chapter 1

    Airmux-5000 hpmp user manual release 3.1.00 1-1 chapter 1 introduction welcome to airmux-5000! Airmux-5000 delivers up to 200mbps and is the ideal choice for last mile enterprise connectiv- ity and high-end applications that demand assured performance with guaranteed bandwidth per subscriber. Airmux...

  • Page 22

    Key features of airmux-5000 chapter 1 airmux-5000 hpmp user manual release 3.1.00 1-2 a sector consists of a bs and a group of sus within the angular sector covered by the bs antenna. A sector is typically 60° or 90° depending of course on the choice of antenna. Bss may be collocated to provide sect...

  • Page 23

    Airmux-5000 components chapter 1 airmux-5000 hpmp user manual release 3.1.00 1-3 airmux-5000 components airmux-5000 hbs high capacity base station the hbs consists of airmux-5000 hbs bs odu, a sector dual-pole antenna and a poe device, which provides a lan interface to user equipment. A single hbs s...

  • Page 24: The Airmux Manager

    The airmux manager chapter 1 airmux-5000 hpmp user manual release 3.1.00 1-4 the airmux manager the airmux manager is an snmp-based management application which manages a complete sector over a single ip address. It can also manage hsus separately. The intuitive, easy-to-use airmux manager has a gra...

  • Page 25

    Viewing and printing chapter 1 airmux-5000 hpmp user manual release 3.1.00 1-5 viewing and printing this manual is optimized for viewing online as a pdf file. To this end it uses an 11 point tahoma typeface for main text. Tables for most part, use 7 or 8 point fonts. Here are a few pointers for hard...

  • Page 26: Chapter 2

    Airmux-5000 hpmp user manual release 3.1.00 2-1 chapter 2 site preparation planning the sector site overview sector site planning consists of a set of surveys, which must be carried out before any equip- ment is deployed. If for some reason, the outcome of any of these surveys is negative, hbs or hs...

  • Page 27: Stage 1: Preliminary Survey

    Stage 1: preliminary survey chapter 2 airmux-5000 hpmp user manual release 3.1.00 2-2 • link budget calculator and/or radio planner stage 2: physical survey • 100 meter tape measure • ohmmeter, to check ground connection • binoculars • map • digital camera • paper, pencil, and a clipboard • gps devi...

  • Page 28: Stage 2: Physical Survey

    Stage 2: physical survey chapter 2 airmux-5000 hpmp user manual release 3.1.00 2-3 stage 2: physical survey the physical site survey reviews the environment of the proposed installation location, to ensure that the sector sites are suitable for the wireless network. The results of the physical site ...

  • Page 29: Stage 3: Rf Survey

    Additional indoor site requirements chapter 2 airmux-5000 hpmp user manual release 3.1.00 2-4 additional indoor site requirements the ambient operating temperature should be 0 to 50°c (32 to 122 °f) at a humidity of up to 90%, non condensing stage 3: rf survey the rf survey examines the wireless env...

  • Page 30: Chapter 3

    Airmux-5000 hpmp user manual release 3.1.00 3-1 chapter 3 hardware installation this chapter sets out the requirements and procedures for the hardware installation and alignment of a airmux-5000 hpmp sector in accordance with the prior planning as set out in chapter 2 . It is intended to guide quali...

  • Page 31: Package Contents

    Protection against lightning chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-2 outdoor units, masts, lead-in wiring and discharge units. It also lays down the size of grounding conductors and connection requirements for grounding electrodes. Airmux-5000 hpmp odus must be grounded to a protec...

  • Page 32

    Hbs and hsu odu package contents chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-3 • link budget calculator • label showing the mac address and the alternative community string. The label is self-adhesive. You should keep this label safe • cable glands (to be used with the odu-poe cable) fig...

  • Page 33

    External antenna package contents chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-4 • connectorized odu this odu has 2xn-type connectors for connecting an external antenna • hsu only - sff (connectorized) odu the sff odu is slightly “fatter” and heavier than a regular connectorized odu since...

  • Page 34

    Hub site synchronization (hss) unit chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-5 basic poe device the basic poe device provides ethernet service only, with power for the odu. The poe device is extremely compact, having one ethernet port, one odu port and a standard 3 pin male ac power s...

  • Page 35

    Gsu chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-6 figure 3-6: hss interconnection unit see chapter 7 for further details about the use of hss. Gsu the gps-based synchronization unit (gsu) is designed to handle inter-site interferences under large-scale deployment scenarios. The gsu is an...

  • Page 36

    Additional tools and materials required chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-7 additional tools and materials required the following is a list of the equipment and materials required to install airmux-5000 hpmp hardware. Tools and materials • crimping tool for rj-45 (if the odu-po...

  • Page 37: Outdoor Installation

    Outdoor installation chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-8 figure 3-8: typical hsu installation with external antenna the hbs installation differs only in the antenna type: the hbs uses a sector antenna. The installation steps are detailed in the following sections. Outdoor insta...

  • Page 38

    Mounting external antennas chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-9 into the unit causing damage.) it is possible to mount an odu horizontally. See chapter 17 for details. 3. Refer also to chapter 17 for detailed odu mounting kit contents and schematics. Mounting external antennas i...

  • Page 39: Aligning Hsus to A Hbs

    Installing a sector using poe devices chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-10 2. Connect the lightning protection device to the odu (see chapter 18 ). 3. Attach the odu-poe cable to the odu rj-45 connector (see appendix b for the connector pinout) 4. Screw in the cable glands to e...

  • Page 40

    Aligning hsus to a hbs chapter 3 airmux-5000 hpmp user manual release 3.1.00 3-11 the details are described in the next two steps. “antenna” refers both to an external antenna and an integrated antenna. The two steps should be carried out for each hsu in the sector. 5. Make a horizontal sweep of 180...

  • Page 41: Part 2: Sector Installation

    Airmux-5000 hpmp point to multipoint broadband wireless user manual release 3.1.00 part 2: sector installation.

  • Page 42: Chapter 4

    Airmux-5000 hpmp user manual release 3.1.00 4-1 chapter 4 getting started with the airmux manager what we will do here this chapter is a quick “hands-on” tour of a running c sector. We show you how to install the airmux manager software on your managing pc, connect it to an operating base station an...

  • Page 43

    Installing the software chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-2 installing the software any pc running the airmux manager application can be used to configure a airmux-5000 hpmp sector. To install the airmux manager application: 1. Insert the cd into the cd/dvd drive of your comput...

  • Page 45

    The airmux manager log-on concept chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-4 figure 4-3: extended log-on window at the user type field, click the list button: figure 4-4: log on window exposing the user types. There are three user types: • an observer has read-only access to the secto...

  • Page 46

    The airmux manager log-on concept chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-5 the following table summarizes these options: the network manager should change the default passwords as soon as possible. Continuing the log-on procedure: 5. If your user type is not operator, then choose it...

  • Page 47: Log-On Errors and Cautions

    Log-on errors and cautions chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-6 figure 4-5: opening airmux manager window - hbs log-on errors and cautions unsupported device attempting to connect to an unsupported device on an otherwise valid ip address (for exam- ple, a lan printer) will resul...

  • Page 48

    Incorrect password chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-7 figure 4-7: unreachable device message in both of the above situations, if you click no, you will see a warning graphic alongside the ip address field. Incorrect password if you type an incorrect password in the login windo...

  • Page 49

    Sector status panel chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-8 sector status panel the sector level information is shown here. There is nothing that can be changed for an active sector. The parameters are set before the base station is activated and are duplicated for each hsu in the ...

  • Page 50

    Base station panel chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-9 figure 4-11: base station detail panel the rx and tx rates are the traffic receive and transmit rates through the hbs odu under load. The button bar provides the necessary functionality to configure and manage the hbs. The ...

  • Page 51

    Hbs events log chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-10 the activation process is covered in detail in chapter 5 . At any time, the current status of the hbs is shown in the sector status panel, figure 4-10 . Hbs events log the events log records system failures, loss of synchroniz...

  • Page 52

    Hbs main window chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-11 hbs main window figure 4-13: hbs main window (reduced) - up to 16 hsus colored fields indicate a problem requiring your attention.The if you mouse-over the colored rss area. You will receive a tool tip telling you that rss fo...

  • Page 53

    Hbs main window chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-12 figure 4-15: hsu display - context menu (right click) figure 4-16: hsu display - detail. Scroll right for more fields the button bar in figure 4-16 follows the same pattern as the context menu in figure 4- 15 . Table 4-6: hsu...

  • Page 54: Logging On to An Hsu

    Exploring the airmux manager main window - hsu chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-13 exploring the airmux manager main window - hsu you may log on to an hsu over the air from a hbs or by directly connecting a managing com- puter to the hsu poe. You can log on over the air to any...

  • Page 55

    Logging on to an hsu chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-14 figure 4-18: opening airmux manager window - hsu.

  • Page 56

    Hsu main button menu chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-15 hsu main button menu the hsu main button menu is similar to the hbs main button menu. The only new item in the configure button. Figure 4-19: hsu main button menu hsu link status table 4-7: hsu main button bar functions ...

  • Page 57

    Hsu events log chapter 4 airmux-5000 hpmp user manual release 3.1.00 4-16 hsu events log the hsu events display is functionally identical to that of the hbs. Hsu link performance for convenience the hsu link performance panel shows the same thins a s in figure 4-14 . For convenience we also display ...

  • Page 58: Chapter 5

    Airmux-5000 hpmp user manual release 3.1.00 5-1 chapter 5 installing the sector scope of this chapter chapter 4 , offered an overview of a running sector as motivation for the technical installa- tion details set out below. Assuming that the sector equipment is in place as described in earlier chapt...

  • Page 59: Workflow

    Workflow chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-2 receives at least one time slot. To disable an hsu you must deregister it. (a suspend mech- anism is also available, to suspend service on an hsu for a fixed period.) for each registered hsu, you can set separately, the uplink and do...

  • Page 60

    Configuring the sector out of the box - ip addresses chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-3 figure 5-2: main window for un-configures hbs odu notice the red icon on the top left corner of the window. It will change to green as soon as the hbs is configured and activated. To config...

  • Page 61

    Configuring the sector out of the box - ip addresses chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-4 figure 5-3: site configuration prior to definition 2. Enter the name, contact and location field. For what follows we will use the values used in chapter 4 . To ensure that your data is cap...

  • Page 62

    Configuring the sector out of the box - ip addresses chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-5 figure 5-4: setting the sector id and rf parameters 4. The sector id may appear blank or some inappropriate default value. You will be able to set it during the activation process. 5. Click...

  • Page 63

    Configuring the sector out of the box - ip addresses chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-6 figure 5-5: definition of ip address done here 6. Enter the ip address, subnet mask and default gateway and then click ok. You are offered a warning: 7. Click yes. The dialog is dismissed a...

  • Page 64: Activating The Hbs

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-7 at this point you should field-install the units according to the guidelines in chapter 3 . You should now revert your network card to the sector subnet. Activating the hbs with all the units in place, log on to the hbs usi...

  • Page 65

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-8 2. Click next: enter the sector id. Choose it carefully particularly if you are using collocated hbss for extra coverage. The sector name and location are convenience items but should be used to ensure that the sector is do...

  • Page 66

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-9 it is best left as is if there is no pressing need to change it. 3. From the previous activation wizard window, click next. Here you may enter the ip details if didn’t do it earlier. Click next. 4. The next window is used t...

  • Page 67

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-10 choosing other allows you to choose a frequency by hand. Otherwise, you may choose from a drop-down list of available frequencies: 5. Click the automatic channel select box:.

  • Page 68

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-11 you make a manual choice of channels or select all as shown. 6. Click next.The antenna and tx power is presented:.

  • Page 69

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-12 when setting required tx power, it is your responsibility to chose a value in compli- ance with your local regulations. Click next. 7. The summary window of the wizard is displayed. If everything looks correct, click the a...

  • Page 70

    Activating the hbs chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-13 figure 5-7: the sector showing hsus configured but unregistered at this point, the hsus can communicate for management but not for service. Observe that both hsus have the rss entry for the hsu shaded yellow. Shading of th...

  • Page 71

    Registering the hsus for service chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-14 registering the hsus for service we continue our illustration using hsu at pm_at_01. To register an hsu for service: 1. Right click an hsu to get its context menu: 2. Click register... The registration window...

  • Page 72

    Registering the hsus for service chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-15 3. Click the evaluate button. Service evaluation takes a few seconds during which the window is darkened and inactive. Upon completion you may assign time slots to the hsu: 4. Click the number of time slots t...

  • Page 73

    Registering the hsus for service chapter 5 airmux-5000 hpmp user manual release 3.1.00 5-16 6. Repeat the process for all other hsus in the sector. Here is the final result for our example: figure 5-8: fully functional sector.

  • Page 74: Chapter 6

    Airmux-5000 hpmp user manual release 3.1.00 6-1 chapter 6 managing the sector scope of this chapter a configuration window is available for both the hbs and the hsus to change setting without necessarily dropping service. Nevertheless care must be exercised when changing them. By way of example, cha...

  • Page 75

    System (hbs and hsu) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-2 system (hbs and hsu) these items may be changed both for the hbs and hsus. They are convenience fields. The hsu button bar has an extra item:.

  • Page 76

    System (hbs and hsu) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-3 the buzzer button may set or mute the buzzer. Recall that the buzzer tone is used for antenna alignment..

  • Page 77

    Air interface (hbs) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-4 air interface (hbs) for the hbs this panel has the same functionality as the corresponding window in the activa- tion wizard (see chapter 5 ). For the hsu, this panel is read only..

  • Page 78

    Air interface (hbs) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-5.

  • Page 79

    Tx and antenna (hbs and hsu) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-6 tx and antenna (hbs and hsu) hub site sync [hss] (hbs) see chapter 7 . Management (hbs and hsu) if you set the ip and related addresses correctly, there should be nothing to change here. Inventory (hbs and hsu) yo...

  • Page 80

    Security (hbs and hsu) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-7 the inventory information will be required by customer support should you require assis- tance. Security (hbs and hsu) here you may change the snmp community strings and the link password..

  • Page 81

    Date and time (hbs and hsu) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-8 date and time (hbs and hsu) ethernet (hbs only) the only field you may change here is the hbs aging time..

  • Page 82: Hsu Connection Table

    Operations (hbs and hsu) chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-9 operations (hbs and hsu) when you are satisfied with your configuration parameters, click ok to save them and dis- miss the configuration window. Hsu connection table from the hbs button bar, click the right hand butt...

  • Page 83

    Hsu connection table chapter 6 airmux-5000 hpmp user manual release 3.1.00 6-10 figure 6-1: hsu intercommunication the green shaded squares show intercommunicating elements within the sector. Mng refers to management traffic which should always be open between hsus and the hbs. Lan refers to service...

  • Page 84: Part 3: Site Synchronization

    Airmux-5000 hpmp point to multipoint broadband wireless user manual release 3.1.00 part 3: site synchronization.

  • Page 85: Chapter 7

    Airmux-5000 hpmp user manual release 3.1.00 7-1 chapter 7 hub site synchronization scope of this chapter this chapter is specific to collocating hbss. Should you require to collocate with other radio models, you should consult with rad customer service. What is hub site synchronization? When several...

  • Page 86

    What is hub site synchronization? Chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-2 figure 7-1: interference caused by collocated units adding hss removes interference as shown in the next two figures: figure 7-2: collocated units using hub site synchronization (1) figure 7-3: collocated uni...

  • Page 87: Hardware Installation

    Hardware installation chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-3 • hss client-continue transmission (hsc-ct): if the unit loses synchronization with the hss master, the link remains active. However, without synchronization pulses, it is possible that this unit will cause interference....

  • Page 88

    Using a single hss unit chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-4 using a single hss unit figure 7-5: hss wiring schematic the wiring, as shown in figure 7-5 is self explanatory. The sync signal path is less self evi- dent. If we set odu 1 (on sync 1) to hss master, then the sync sig...

  • Page 89

    Using more than one hss unit chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-5 2. The next available sync port of the first hss unit should be connected to sync 10 of the second hss unit as shown in figure 7-7 . In the illustration, the next available port on the first hss unit is sync 6. 3....

  • Page 90: Radio Frame Pattern (Rfp)

    Odu/hss unit connection pinout chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-6 condition 2: total hss cable length the total path of the hss sync pulse must not exceed 300m. This applies no matter how many hss units are used. To illustrate the method for calculating the sync pulse path len...

  • Page 91

    Rfp and hss chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-7 rfp and hss when hss is used, the rfp for the collocated radios must be selected manually. Airmux-5000 radios use the time division duplex (tdd) mechanism. Under hss, tdd enables synchronization of transmission for the collocated ...

  • Page 92: Sector Configuration and Hss

    Rfp: general radio frame pattern chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-8 select the rfp that gives you the best fit or available for required system services and select the channel bandwidth accordingly. Rfp: general radio frame pattern when setting the rpf, the following considera...

  • Page 93

    Sector configuration and hss chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-9 figure 7-10: hss settings window if you click the enabled box, the central display (with operational state opened) will look like this: figure 7-11: setting hbs as hsm or hsc continue tx means that the hbs as a cl...

  • Page 94

    Sector configuration and hss chapter 7 airmux-5000 hpmp user manual release 3.1.00 7-10 figure 7-12: hbs as hsm the possible external pulses conditions are shown in the following table: table 7-5: external pulse status hss sync status meaning color code generating odu is hsm and generates the sync p...

  • Page 95: Part 4: Field Installation

    Airmux-5000 hpmp point to multipoint broadband wireless user manual release 3.1.00 part 4: field installation topics.

  • Page 96: Chapter 8

    Airmux-5000 hpmp user manual release 3.1.00 8-1 chapter 8 pole and wall installation odu mounting kit contents table 8-1: bill of materials: odu mounting kit item qty large clamp (see figure 8-1 ) 1 small clamp (see figure 8-2 ) 1 arm (see figure 8-3 ) 1 screw hex head m8x40 4 screw hex head m8x70 2...

  • Page 97: Mounting An Odu On A Pole

    Mounting an odu on a pole chapter 8 airmux-5000 hpmp user manual release 3.1.00 8-2 mounting an odu on a pole figure 8-4: mounting on a pole.

  • Page 98: Mounting An Odu On A Wall

    Mounting an odu on a wall chapter 8 airmux-5000 hpmp user manual release 3.1.00 8-3 mounting an odu on a wall figure 8-5: mounting on a wall.

  • Page 99: Mounting An External Antenna

    Mounting an external antenna chapter 8 airmux-5000 hpmp user manual release 3.1.00 8-4 mounting an external antenna optional external antennas can be mounted on a pole. The external mounting kit varies according to the specific antenna model. Mounting a connectorized odu horizontally what follows ap...

  • Page 100: Chapter 9

    Airmux-5000 hpmp user manual release 3.1.00 9-1 chapter 9 lightning protection and grounding guidelines meticulous implementation of the guidelines in this chapter will provide best protection against electric shock and lightning. The rad lightning protection system consists of the following compone...

  • Page 101

    Grounding for indoor/outdoor units chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-2 figure 9-1: grounding antenna cables grounding for indoor/outdoor units odu grounding rad lightning protection system uses a shielded cat-5e cable to interconnect the outdoor (odu) and indoor (idu) units. Ho...

  • Page 102

    Idu grounding chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-3 idu grounding the idu’s grounding post should be connected to the internal ground point, using a ground- ing wire of at least 10 awg. The grounding wire should be connected to a grounding rod or the building grounding system. Th...

  • Page 103

    External lightning surge suppressors and grounding chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-4 figure 9-2: grounding a typical pole installation.

  • Page 104

    External lightning surge suppressors and grounding chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-5 figure 9-3: grounding a typical wall installation the next figure shows a close-up of the rear of grounded odu: figure 9-4: odu surge suppressor and grounding.

  • Page 105

    External lightning surge suppressors and grounding chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-6 the transtector protection circuits shown in figure 9-5 below, utilize silicon avalanche diode technology. The unit consists of an outdoor rated nema 3r type enclosure with easy mount- ing fl...

  • Page 106

    External lightning surge suppressors and grounding chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-7 a second surge arrestor unit should be mounted at the building entry point and must be grounded, as shown in figure 9-3 above. To mount the lightning protection at the building entry point: 1...

  • Page 107

    Internal esd protection circuits chapter 9 airmux-5000 hpmp user manual release 3.1.00 9-8 internal esd protection circuits rad equipment is designed to meet the etsi/fcc/aus/nz/csa emc and safety requirements. To fulfill these requirements, the system's telecom lines at the odu/idu are transformer-...

  • Page 108: Part 5: Product Reference

    Product reference airmux-5000 hpmp point to multipoint broadband wireless user manual release 3.1.00 part 5: product reference.

  • Page 109: Appendix A

    Airmux-5000 hpmp user manual release 3.1.00 a-1 appendix a technical specifications scope of these specifications this appendix contains technical specifications for the major link components appearing in this user manual. They are correct at the date of publication, but are intended for general bac...

  • Page 110

    Odu - hbs and hsu appendix a airmux-5000 hpmp user manual release 3.1.00 a-2 ic 5.4 5.480 – 5.590 5.660 – 5.715 ic rss-210 yes fcc/ic 5.3 5.260 - 5.340 fcc 47cfr, part 15, subpart e and ic rss-210 yes fcc/ic 4.9 4.940 - 4.990 fcc 47cfr, part 90, subpart y and ic rss-111 yes wpc india 5.8 5.825 – 5.8...

  • Page 111

    Gbe poe device - indoor, ac for hbs only appendix a airmux-5000 hpmp user manual release 3.1.00 a-3 gbe poe device - indoor, ac for hbs only ac input voltage 100-240vac nominal, 90-264vac max range input frequency 47-63hz input current 2.0a (rms) 115vac at max. Load 1.2a (rms) 230vac at max. Load ou...

  • Page 112: Poe Device - Indoor, Ac

    Poe device - indoor, ac appendix a airmux-5000 hpmp user manual release 3.1.00 a-4 poe device - indoor, ac poe device - outdoor, dc ac input voltage 100-240vac nominal, 85-265vac max range input frequency 47-63hz input current 1.5a max at 90vac, 0.75a max at 265vac output voltage and current 55vdc, ...

  • Page 113: Gsu

    Gsu appendix a airmux-5000 hpmp user manual release 3.1.00 a-5 gsu power consumption 0.5w (not including radio) protections differential - 15kw common – 3kw ethernet lan interface type rj 45, 10/100baset interface (line impedance -100) dc input 2 pins connector poe to odu interface outdoor cat-5e; ...

  • Page 114: Antenna Characteristics

    Antenna characteristics appendix a airmux-5000 hpmp user manual release 3.1.00 a-6 antenna characteristics an antenna is the radiating and receiving element from which the radio signal, in the form of rf power, is radiated to its surroundings and vice versa. The transmission range is a function of t...

  • Page 115: Appendix B

    Airmux-5000 hpmp user manual release 3.1.00 b-1 appendix b wiring specifications odu-poe cable the odu-poe cable is shielded/outdoor class cat-5e, 4 twisted-pair 24 awg terminated with rj-45 connectors on both ends. A cable gland on the odu side provides hermetic sealing. The following table shows t...

  • Page 116: User Port Connectors

    User port connectors appendix b airmux-5000 hpmp user manual release 3.1.00 b-2 user port connectors lan port the lan 10/100baset interface terminates in an 8-pin rj-45 connector, wired in accordance to table b-3 . Example for connecting the alarm connector dc power terminals dc poe white/brown 7 7 ...

  • Page 117: Appendix C

    Airmux-5000 hpmp user manual release 3.1.00 c-1 appendix c rf exposure the antennas used for the following transmitters must be installed so as to provide a mini- mum separation distance from bystanders as specified in the following tables: table c-1: safety distances for airmux-5000 hpmp fcc and ic...

  • Page 118

    Rf exposure appendix c airmux-5000 hpmp user manual release 3.1.00 c-2.

  • Page 119: Appendix D

    Airmux-5000 hpmp user manual release 3.1.00 d-1 appendix d regional notice: french canadian procédures de sécurité généralités avant de manipuler du matériel connecté à des lignes électriques ou de télécommunications, il est conseillé de se défaire de bijoux ou de tout autre objet métallique qui pou...

  • Page 120

    Précautions de sécurité pendant le montage de odu appendix d airmux-5000 hpmp user manual release 3.1.00 d-2 seille l'utilisation d'un dispositif de parafoudre supplémentaire afin de protéger le matériel de coups de foudre proches. Matériel supplémentaire requis l'équipement requis pour l'installati...

  • Page 121

    Contenu du kit de montage odu appendix d airmux-5000 hpmp user manual release 3.1.00 d-3 contenu du kit de montage odu le kit de montage odu comprend les pièces suivantes: • une grande clame (voir figure d-1 ) • une petite clame (voir figure d-2 ) • un bras (voir figure d-3 ) • quatre visses hex têt...

  • Page 122

    Montage sur un pylône appendix d airmux-5000 hpmp user manual release 3.1.00 d-4 figure d-4: montage sur un pylône.

  • Page 123

    Montage sur un mur appendix d airmux-5000 hpmp user manual release 3.1.00 d-5 montage sur un mur figure d-5: montage sur un mur.

  • Page 124

    Montage d'une antenne externe appendix d airmux-5000 hpmp user manual release 3.1.00 d-6 montage d'une antenne externe l'antenne externe optionnelle peut être montée sur un pylône. Contenu du kit de montage d'une antenne externe le kit de montage d'une antenne externe comprend les pièces suivantes •...

  • Page 125: Index

    Airmux-5000 hpmp user manual release 3.1.00 index 1 a air interface technical specifications, general a-1 antennas aligning buzzer signals 3-11 cable, grounding 9-1 external 3-4 mounting 3-9 package contents 3-4 external, mounting 8-4 d dc power terminal pinout b-2 f fec a-1 , a-1 g gsu a-5 h hss ha...

  • Page 126

    Airmux-5000 hpmp user manual release3.1.00 index 2 odus 9-2 internal esd protection circuits 9-8 r radio frame pattern (rfp) general considerations 7-8 general considerations 7-8 with hss 7-7 without hss 7-6 radio link additional tools and materials required 3-7 connecting user equipment 3-10 hardwa...

  • Page 127: Customer Response Form

    24 raoul wallenberg street, tel aviv 69719, israel tel: +972-3-6458181, fax +972-3-6483331, +972-3-6498250 e-mail: erika_y@rad.Com , web site: http://www.Rad.Com customer response form rad data communications would like your help in improving its product documentation. Please complete and return thi...

  • Page 129

    Error report type of error(s) or problem(s): incompatibility with product difficulty in understanding text regulatory information (safety, compliance, warnings, etc.) difficulty in finding needed information missing information illogical flow of information style (spelling, grammar, references, etc....

  • Page 132

    Publication no. 649-100-05/11 order this publication by catalog no. 803968 international headquarters 24 raoul wallenberg street tel aviv 69719, israel tel. 972-3-6458181 fax 972-3-6498250, 6474436 e-mail market@rad.Com north america headquarters 900 corporate drive mahwah, nj 07430, usa tel. 201-52...