RAD Data Communications ASMi-52 Installation And Operation Manual - Chapter 1

Manual is about: 2/4-Wire SHDSL Modem

Summary of ASMi-52

  • Page 1

    Installation and operation manual asmi-52 2/4-wire shdsl modem version 2.5b.

  • Page 3: Notice

    Asmi-52 version 2.5 b 2/4-wire shdsl modem installation and operation manual notice this manual contains information that is proprietary to rad data communications ltd. ("rad"). No part of this publication may be reproduced in any form whatsoever without prior written approval by rad data communicat...

  • Page 4: Limited Warranty

    Limited warranty rad warrants to distributor that the hardware in the asmi-52 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to distributor. If, during the warranty period, ...

  • Page 5: General Safety Instructions

    General safety instructions the following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety symbols this symbol may appear on the equipment or in the text. It in...

  • Page 6: Handling Energized Products

    Handling energized products general safety practices do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the off position or a fuse is blown. For dc-powered products, altho...

  • Page 7

    Connection of data and telecommunications cables data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manu...

  • Page 8: Fcc-15 User Information

    To reduce the risk of fire, use only no. 26 awg or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 awg ou de section supérieure. Some ports are suitable for connection to intra-building or non-exposed wiring or cab...

  • Page 9

    Canadian emission requirements this class a digital apparatus meets all the requirements of the canadian interference-causing equipment regulation. Cet appareil numérique de la classe a respecte toutes les exigences du règlement sur le matériel brouilleur du canada. Warning per en 55022 (cispr-22) t...

  • Page 10: Declaration of Conformity

    Declaration of conformity manufacturer's name: rad data communications ltd. Manufacturer's address: 24 raoul wallenberg st. Tel aviv 69719 israel declares that the product: product name: asmi-52 conforms to the following standard(s) or other normative document(s): emc: en 55022: 1994 limits and meth...

  • Page 11: Quick Start Guide

    Configuring asmi-52 1 quick start guide installation of asmi-52 should be carried out only by an experienced technician. If you are familiar with asmi-52, use this guide to prepare the units for operation. 1. Installing asmi-52 connecting the interfaces 1. Connect the line to the rj-45 rear panel co...

  • Page 12

    Quick start guide asmi-52 installation and operation manual 2 configuring asmi-52 configuring the master clock to configure the master clock: • from the system configuration menu (main menu > configuration > system configuration > master clock), configure the central asmi-52 clock to external or int...

  • Page 13

    Asmi-52 installation and operation manual quick start guide configuring asmi-52 3 to configure e1 parameters: • from the e1 port configuration menu (main menu > configuration > port configuration > e1 port configuration), configure the following e1 parameters: framing mode timeslot assignment • you ...

  • Page 14

    Quick start guide asmi-52 installation and operation manual 4 configuring asmi-52.

  • Page 15: Contents

    Asmi-52 installation and operation manual i contents chapter 1. Introduction 1.1 overview..................................................................................................................... 1-1 versions....................................................................................

  • Page 16

    Table of contents ii asmi-52 installation and operation manual setting the g.704 interface type......................................................................................... 4-22 4.3 configuring the physical ports ..............................................................................

  • Page 17: Chapter 1

    Overview 1-1 chapter 1 introduction 1.1 overview asmi-52 is an shdsl modem that operates in full duplex over 2/4-wire lines and offers a cost-effective solution for delivering digital data to customer premises over existing copper cables. Asmi-52 handles multiple data rates in the range of 64– 4608 ...

  • Page 18

    Chapter 1 introduction asmi-52 installation and operation manual 1-2 overview unit enclosure asmi-52 is available in a plastic, metal, or rail-mount enclosure. Applications figure 1-1 illustrates a typical asmi-52 application, in which standalone modems operate opposite each other. Figure 1-2 shows ...

  • Page 19

    Asmi-52 installation and operation manual chapter 1 introduction overview 1-3 figure 1-2. Asmi-52 modems operating opposite a centrally located lrs-24 rack figure 1-3. Asmi-52 modems operating opposite asmi-52cd cards.

  • Page 20

    Chapter 1 introduction asmi-52 installation and operation manual 1-4 overview features functionality asmi-52 can be configured to operate in a co (central office) or cpe (customer premises equipment) mode. Line interface asmi-52 extends the range of data transmission over 2/4-wire lines up to 7.0 km...

  • Page 21

    Asmi-52 installation and operation manual chapter 1 introduction overview 1-5 dte interface asmi-52 supports the following dte interfaces: • x.21 • v.35 • rs-530 • e1, as per g.704 • t1 • ethernet/fast ethernet bridge with vlan support (combined with management lan port) • ir-ip (ip router). When as...

  • Page 22

    Chapter 1 introduction asmi-52 installation and operation manual 1-6 overview table 1-2. Asmi-52 data rates dte interface and clock mode line interface local asmi-52 remote asmi-52 2-wire 4-wire serial dte interface, internal clock serial dte interface n × 64 kbps (n = 1, 2, … 32, 36) n × 128 kbps (...

  • Page 23

    Asmi-52 installation and operation manual chapter 1 introduction overview 1-7 multiplexer applications • the multiplexer unit cannot be configured as a device with lan only port. It must have a dte or ir port. • the hardware of a single unit-based product with a lan port manager is different from th...

  • Page 24

    Chapter 1 introduction asmi-52 installation and operation manual 1-8 overview table 1-4. Possible multiplexer applications (cont.) co/cpe e1 serial dte lan e1+serial dte e1+lan serial dte+lan e1↔e1 e1↔serial dte e1↔lan e1↔e1+serial dte e1↔e1 e1↔serial dte e1+lan↔e1 e1↔e1 e1↔serial dte e1↔e1+lan e1↔s...

  • Page 25

    Asmi-52 installation and operation manual chapter 1 introduction overview 1-9 management asmi-52 supports the following management options: • ascii terminal or easy config hand-held device via v.24/rs-232 terminal port • telnet via a dedicated 10/100baset port • snmp network management (radview) via...

  • Page 26

    Chapter 1 introduction asmi-52 installation and operation manual 1-10 physical description statistics collection asmi-52 supports shdsl and e1/t1 statistics collection. Alarm reporting asmi-52 alarms are relayed via a dedicated 6-pin terminal block connector. Shdsl repeaters up to eight shdsl repeat...

  • Page 27

    Asmi-52 installation and operation manual chapter 1 introduction functional description 1-11 1.3 functional description this section provides a functional description of asmi-52 in the form of block diagrams ( figure 1-5 and figure 1-6 ). Modem glue logic data & clock leds and terminal interface con...

  • Page 28

    Chapter 1 introduction asmi-52 installation and operation manual 1-12 functional description the asmi-52 modem consists of the following major modules: dte interface – prepares the digital data coming from the dte into a data stream for modem glue logic. In addition, it translates the data from the ...

  • Page 29

    Asmi-52 installation and operation manual chapter 1 introduction technical specifications 1-13 1.4 technical specifications line interface type 2/4-wire unconditioned dedicated line (twisted pair) line coding tc-pam range see table 1-1 impedance 135Ω connectors • asmi-52: rj-45 • asmi-52cd: two rj-4...

  • Page 30

    Chapter 1 introduction asmi-52 installation and operation manual 1-14 technical specifications management ports v.24/rs-232 control port interface v.24/rs-232 dte connector 9-pin d-type, female format asynchronous baud rate 9.6 to 115.2 kbps ethernet port interface 10/100baset connector rj-45 shield...

  • Page 31

    Asmi-52 installation and operation manual chapter 1 introduction technical specifications 1-15 indicators pwr (green) power test (red) test sync a/b (green/red) synchronization of dsl line data (yellow) data transfer (except e1 and t1 options) e1/t1 sync (red) loss of e1/t1 synchronization (e1 and t...

  • Page 32

    Chapter 1 introduction asmi-52 installation and operation manual 1-16 technical specifications environment temperature standalone: 0° – 50°c (32° – 122°f) rail-mount: −20° – 70°c (−4° – 158°f) humidity up to 90%, non–condensing shock (rail-mount) iec 60068-2-27 shock 15g, 11 ms duration, 18 shocks v...

  • Page 33: Chapter 2

    Introduction 2-1 chapter 2 installation and setup 2.1 introduction this chapter describes installation and setup procedures for the standalone asmi-52 modem. After installing the unit: • refer to chapter 3 for the operating instructions. • refer to chapter 4 for the detailed system configuration pro...

  • Page 34

    Chapter 2 installation and setup asmi-52 installation and operation manual 2-2 connecting the interface cables 2.2 site requirements and prerequisites ac-powered asmi-52 units should be installed within 1.5m (5 ft) of an easily-accessible grounded ac outlet capable of furnishing the voltage in accor...

  • Page 35

    Asmi-52 installation and operation manual chapter 2 installation and setup connecting the interface cables 2-3 e1/t1 shdsl dce v.35 control alarm line b tx line a rx 1 1 4 4 2 2 5 5 act link figure 2-1. Asmi-52 rear panel (plastic enclosure) shdsl control line b line a 1 4 2 5 act link figure 2-2. A...

  • Page 36

    Chapter 2 installation and setup asmi-52 installation and operation manual 2-4 connecting the power cables to connect the dte interface: • connect the dte to the appropriate rear panel dte interface connector of the asmi-52 modem. Appendix a specifies the dte connector pinouts. Connecting the alarm ...

  • Page 37: Chapter 3

    Controls and indicators 3-1 chapter 3 operation this chapter provides the following information for the asmi-52 modem: • asmi-52 front-panel indicators • operating procedures (turn-on, front-panel indications, performance monitoring and turn-off) • asmi-52 default settings. Installation procedures g...

  • Page 38

    Chapter 3 operation asmi-52 installation and operation manual 3-2 controls and indicators asmi-52 figure 3-1. Asmi-52 front panel, e1 interface (2 wire) figure 3-2. Asmi-52 front panel, e1 interface (4 wire) figure 3-3. Asmi-52 front panel, t1 interface (4 wire) asmi-52 figure 3-4. Asmi-52 front pan...

  • Page 39

    Asmi-52 installation and operation manual chapter 3 operation controls and indicators 3-3 table 3-1. Asmi-52 front panel leds name function pwr (green) on – power is on tst (red) on – a loopback test is active in a local or remote unit sync a (red/green) on (red) – link a is not synchronized on (gre...

  • Page 40

    Chapter 3 operation asmi-52 installation and operation manual 3-4 default settings 3.3 default settings asmi-52 is managed by an ascii terminal or a pc running a terminal emulation program via a menu-driven embedded software. Table 3-4 lists the default settings of the asmi-52 configuration paramete...

  • Page 41

    Asmi-52 installation and operation manual chapter 3 operation default settings 3-5 parameter default value control port control port rate 9600 bps data 8 parity none interface dce cts =rts dsr on port control mode terminal user name – password 1234 pop alarm off security timeout 10 min call out mode...

  • Page 42

    Chapter 3 operation asmi-52 installation and operation manual 3-6 default settings parameter default value serial dte interface rate single: 2-wire – 192 kbps 4-wire – 384 kbps multiplexer: 1. E1+serial dte, n/a, 0 kbps 2. Lan+serial dte: 2-wire – 192 kbps 4-wire – 384 kbps llb from dte disable rlb ...

  • Page 43

    Asmi-52 installation and operation manual chapter 3 operation configuration alternatives 3-7 3.4 configuration alternatives after installation, asmi-52 can be reconfigured using different ports and applications: • local out-of-band management via an ascii terminal or the easy config device connected...

  • Page 44

    Chapter 3 operation asmi-52 installation and operation manual 3-8 configuration alternatives data terminal ready (dtr) when connected and turned on, the terminal sets the dtr line on (active) to gain control over asmi-52 and starts a configuration or monitoring session. Initiating a control session ...

  • Page 45

    Asmi-52 installation and operation manual chapter 3 operation configuration alternatives 3-9 navigating data forms some of the asmi-52 management software screens are data forms, which are bigger than regular menus and require scrolling to navigate between parameters. For example, the inventory scre...

  • Page 46

    Chapter 3 operation asmi-52 installation and operation manual 3-10 configuration alternatives figure 3-8. Configurad login managing asmi-52 via a dedicated timeslot asmi-52 modems with e1 or t1 interface can be managed via a dedicated e1/t1 timeslot (dts) (see figure 3-9 ). The dts is a management c...

  • Page 47

    Asmi-52 installation and operation manual chapter 3 operation configuration alternatives 3-11 managing asmi-52 via web browser configurad is a web-based remote access terminal management software. It provides a user-friendly interface for configuring, collecting statistics, and performing diagnostic...

  • Page 48

    Chapter 3 operation asmi-52 installation and operation manual 3-12 configuration alternatives figure 3-10. Inventory and configuration menus.

  • Page 49

    Asmi-52 installation and operation manual chapter 3 operation configuration alternatives 3-13 some of the management menu options depend on the type of the dte interface installed in asmi-52: • dts configuration (main menu > configuration > system configuration > management) is available only for th...

  • Page 50

    Chapter 3 operation asmi-52 installation and operation manual 3-14 configuration alternatives figure 3-11. Monitoring, diagnostics and file utilities menus.

  • Page 51

    Asmi-52 installation and operation manual chapter 3 operation turning off asmi-52 3-15 logging out to end the current session: • in the main menu, click logout or type & in a terminal management screen. • • asmi-52 allows at least four management sessions to be active at a time. If the web-based man...

  • Page 52

    Chapter 3 operation asmi-52 installation and operation manual 3-16 turning off asmi-52.

  • Page 53: Chapter 4

    Configuring asmi-52 for management 4-1 chapter 4 configuration 4.1 configuring asmi-52 for management the configuration of asmi-52 is performed via a menu-driven embedded software, using a standard ascii terminal or a pc running a terminal emulation application connected to the rear panel control po...

  • Page 54

    Chapter 4 configuration asmi-52 installation and operation manual 4-2 configuring asmi-52 for management entering device information the device information menu allows you to assign a name to asmi-52, define its location, and contact person. These entries may include up to 20 characters. To enter de...

  • Page 55

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 for management 4-3 configuring the host parameters asmi-52 can be managed by a network management station, which is located on the lan connected to the 10/100baset port. In order to establish a proper connection, i...

  • Page 56

    Chapter 4 configuration asmi-52 installation and operation manual 4-4 configuring asmi-52 for management 3. Type a number corresponding to a subnet mask of the already defined network management station, and enter a new value. 4. Repeat step 2 and step 3 to define additional management stations. 5. ...

  • Page 57

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 for management 4-5 asmi-52 management access 1. Telnet allowed (access allowed) 2. Web allowed (access allowed) > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-6. Management access menu configuring dedicat...

  • Page 58

    Chapter 4 configuration asmi-52 installation and operation manual 4-6 configuring asmi-52 for management asmi-52 rem agent table source ip destination ip port > esc-prev. Menu; !-main menu; &-exit; @-scroll; ?-help figure 4-8. Rem agent table configuring vlan encapsulation asmi-52 is occasionally co...

  • Page 59

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 for management 4-7 configuring the lan port asmi-52 includes a 10/100baset port that can be used as a user or management port. The lan port operates in a self-learning bridge or transparent mode, with or without au...

  • Page 60

    Chapter 4 configuration asmi-52 installation and operation manual 4-8 configuring asmi-52 for management • if autonegotiation is enabled, the maximum autonegotiation capability rate is 100baset full duplex mode. If autonegotiation is disabled, it is called default type or 10baset. Filling out the br...

  • Page 61

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 for management 4-9 asmi-52 bridge table type (static) 1. Mac address ... (00000000000) 2. Port ... () > esc-prev. Menu; !-main menu; &-exit; ?-help figure 4-12. Bridge table, editing mode configuring aging timeout ...

  • Page 62

    Chapter 4 configuration asmi-52 installation and operation manual 4-10 configuring asmi-52 for management asmi-52 qos mapping (classification 802.1p) 1. User priority 0 > (traffic class 0) 2. User priority 1 > (traffic class 0) 3. User priority 2 > (traffic class 0) 4. User priority 3 > (traffic cla...

  • Page 63

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 for management 4-11 2. From the lan rate menu, select the required data rate. The local lan configuration menu appears. 3. From the lan configuration menu, select save to save the new value. Asmi-52 data rate (2304...

  • Page 64

    Chapter 4 configuration asmi-52 installation and operation manual 4-12 configuring asmi-52 for management configuring autonegotiation asmi-52 autonegotiation allows you to operate at the fastest data rate available. With autonegotiation enabled, the asmi-52 unit automatically determines between itse...

  • Page 65

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 system parameters 4-13 4.2 configuring asmi-52 system parameters this section describes the procedures for configuring system parameters of asmi-52. To access the configuration menu: • from the main menu, select co...

  • Page 66

    Chapter 4 configuration asmi-52 installation and operation manual 4-14 configuring asmi-52 system parameters asmi-52 system configuration > 1. Master clock >(internal) 2. Local card mode 3. Remote card mode 4. Low speed operation (enable/disable) 5. Management > 6. Control port > 7. Factory default ...

  • Page 67

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 system parameters 4-15 configuring local card mode each multiplexer unit may be configured as a single parameter by the local/remote card mode. For example, e1 + ir (serial dte) interface may be configured as e1 or...

  • Page 68

    Chapter 4 configuration asmi-52 installation and operation manual 4-16 configuring asmi-52 system parameters configuring low speed operation asmi-52 can be configured to work at a speed of 64/128 kbps (2-wire) and 64/128/192/256 kbps (4-wire) when operating opposite devices with e1 dte interface. Th...

  • Page 69

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 system parameters 4-17 changing the control port data rate the control port of asmi-52 supports different data rates that can be configured via the rate menu (see figure 4-21 ). To configure the control port data r...

  • Page 70

    Chapter 4 configuration asmi-52 installation and operation manual 4-18 configuring asmi-52 system parameters selecting the dsr state to select the dsr state: 1. From the control port menu, select dsr (main menu > configuration > system configuration > control port > dsr) to choose the dsr state: on ...

  • Page 71

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 system parameters 4-19 to configure port control mode: 1. From the port control menu, select port control mode (main menu > configuration > system configuration > control port > port control > port control mode). T...

  • Page 72

    Chapter 4 configuration asmi-52 installation and operation manual 4-20 configuring asmi-52 system parameters the following dialog appears: asmi-52 change access 1. User name ...() 2. Password ... 3. Clear user name ... 4. Clear password ... > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-25...

  • Page 73

    Asmi-52 installation and operation manual chapter 4 configuration configuring asmi-52 system parameters 4-21 • auto-answer mode (at s0=1 and at s1=1) • call set up in response to the connect string (at x0) • no echo (at e0) • verbose mode (no codes, e.G., connect string instead of 0) (at v1). 1. Fro...

  • Page 74

    Chapter 4 configuration asmi-52 installation and operation manual 4-22 configuring the physical ports asmi-52 dial out 1. Call out mode (none) 2. Number of retries [0-8] (1) 3. Wait for connect (sec) (30 sec) 4. Dial mode (tone) 5. Alternate number mode (disable) 6. Primary number () 7. Alternate nu...

  • Page 75

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-23 • asmi-52 units operating in the receive clock mode automatically detect the standard compatibility value of the central units and configure themselves accordingly. Asmi-52 shdsl local port configur...

  • Page 76

    Chapter 4 configuration asmi-52 installation and operation manual 4-24 configuring the physical ports 2. Select save to save the changes. • • after changing the configured wire option, asmi-52 must be reset to implement the change. • when operating in line prob. Adaptive rate, and the clock is inter...

  • Page 77

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-25 configuring the current margin the current margin indicates the minimum required target margin for the local line conditions during the startup sequence. This setting is available only if the rate a...

  • Page 78

    Chapter 4 configuration asmi-52 installation and operation manual 4-26 configuring the physical ports configuring line probing by configuring this parameter, you force asmi-52 to perform line probing in order to find the best possible rate of transmission – adaptive rate. Or you command the modem to...

  • Page 79

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-27 the snr margin threshold can also be configured from the shdsl remote or local port, or from the shdsl repeater. 2. Enter the required value (0 db to 15 db). 3. Select save to save the changes. Conf...

  • Page 80

    Chapter 4 configuration asmi-52 installation and operation manual 4-28 configuring the physical ports asmi-52 data rate (384 kbps) 1. 64 kbps 13. 832 kbps 25. 1600 kbps 2. 128 kbps 14. 896 kbps 26. 1664 kbps 3. 192 kbps 15. 960 kbps 27. 1728 kbps 4. 256 kbps 16. 1024 kbps 28. 1792 kbps 5. 320 kbps 1...

  • Page 81

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-29 • enabling generation and checking of check bits for the frames transmitted on the e1 port (as per crc-4 polynomial specified by itu g.704). Check bits generation is available only for the g732n fra...

  • Page 82

    Chapter 4 configuration asmi-52 installation and operation manual 4-30 configuring the physical ports selecting e1/t1 framing mode to select e1 framing mode: 1. From the e1 local port/t1 local port menu, select framed mode (main menu > configuration > e1 configuration/t1 configuration > e1 local por...

  • Page 83

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-31 asmi-52 sync mode (ccitt (complies with g732)) 1. Fast (after 1 sec) 2. 62411 (after 10 sec) 3. Ccitt (complies with g732) > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-35. Sync mode menu...

  • Page 84

    Chapter 4 configuration asmi-52 installation and operation manual 4-32 configuring the physical ports 2. Assign a timeslot to carry data by typing the corresponding number and press . The timeslot value changes to: data – timeslot is configured to carry user data mng – timeslot is dedicated to carry...

  • Page 85

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-33 mapping e1/t1 timeslots in the multiplexer unit the maximum multiplexer rate is 2048 kbps (general rate). The sum of the data rate of two interfaces should not exceed 2048 kbps. For example: • ir (d...

  • Page 86

    Chapter 4 configuration asmi-52 installation and operation manual 4-34 configuring the physical ports 2. From the e1/t1 local/remote port menu, select units identical setting. The units identical setting value changes to yes. 3. Save the changes. E1 conditions the following are commonly used e1 cond...

  • Page 87

    Asmi-52 installation and operation manual chapter 4 configuration configuring the physical ports 4-35 if the frame mode is “g732s transparent”: • the unit identical set is read-only. • the sync mode, idle code and tsa are read-write for ne if the ne is co, else it is read-only. Configuring the t1 in...

  • Page 88

    Chapter 4 configuration asmi-52 installation and operation manual 4-36 configuring the physical ports • configuration of the sync mode, idle mode, timeslot assignment and matching of t1 setting of the local and remote units is identical of that of the e1 interface. Refer to configuring the e1 interf...

  • Page 89

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-37 4.4 additional tasks displaying the asmi-52 status the asmi-52 software allows you to display the modem system and physical port information. The status information is available via the monitoring menu. To access...

  • Page 90

    Chapter 4 configuration asmi-52 installation and operation manual 4-38 additional tasks asmi-52 system status local remote device type (asmi52_sa_m (plastic)-stu_c-2w) asmi52_sa clock source (int) rcv software version (2.01e24) (2.01e24) hardware version (0.00) (0.00) fpga version (0.13) (0.13) hard...

  • Page 91

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-39 displaying the port status to display the port status information: 1. From the physical port status menu, select port status (main menu > monitoring > physical port status > port status) to display the port statu...

  • Page 92

    Chapter 4 configuration asmi-52 installation and operation manual 4-40 additional tasks to close a virtual terminal • from the monitoring menu of the second asmi-52, select close virtual connection . The main menu of the first asmi-52 is displayed. Entering the user name and password once you have i...

  • Page 93

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-41 asmi-52 main menu 1. Inventory 2. Configuration 3. Monitoring 4. Diagnostics 5. File utilities > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-43. Main menu (terminal session) figure 4-44. Main menu (con...

  • Page 94

    Chapter 4 configuration asmi-52 installation and operation manual 4-42 additional tasks to display the asmi-52 inventory: 1. From the main menu, select inventory. The inventory screen appears (see figure 4-45 ). 2. Use the following keys to move around the indices. • l – move left, l – scroll left, ...

  • Page 95

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-43 if a failure occurs during downloading or decompression, the new version is erased from the flash and the backup version becomes active. In this case, only one version is left stored in the flash memory. If the a...

  • Page 96

    Chapter 4 configuration asmi-52 installation and operation manual 4-44 additional tasks installing a new software release via xmodem • • installation of the new software releases via xmodem is not possible over telnet. • to minimize the software downloading time, it is recommended to configure the c...

  • Page 97

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-45 3. Select tftp or xmodem (as in software download). Asmi-52 auto configuration 1. Xmodem 2. Tftp 3. Command (upload/download full/download part) esc-prev. Menu; !-main menu; &-exit figure 4-47. Software version s...

  • Page 98

    Chapter 4 configuration asmi-52 installation and operation manual 4-46 additional tasks displaying the software version you can display the information on the software revision of the local or remote modem. The information includes a description of the active program, which is currently used by asmi...

  • Page 99

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-47 2. Type y to confirm the file swap. Asmi-52 performs the swap and sends the following string: program switching the active software becomes the backup and vice versa. At this stage, asmi-52 is automatically reset...

  • Page 100

    Chapter 4 configuration asmi-52 installation and operation manual 4-48 additional tasks 2. From the factory default menu, perform one of the following steps: select local factory default to reset the local asmi-52. Select remote factory default to reset the remote device. Select local factory defaul...

  • Page 101

    Asmi-52 installation and operation manual chapter 4 configuration additional tasks 4-49 asmi-52 local reset local line number (1) 1. Local device reset 2. Local shdsl line reset > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-51. Local reset menu resetting the shdsl repeater you can reset t...

  • Page 102: Chapter 5

    Overview 5-1 chapter 5 configuring a typical application 5.1 overview this chapter provides detailed instructions for setting up two asmi-52 modems in a typical application. Asmi-52 configuration is performed via a menu-driven embedded software using a standard ascii terminal or a pc running a termi...

  • Page 103

    Chapter 5 configuring a typical application asmi-52 installation and operation manual 5-2 configuring the asmi-52 units 5.2 configuring the asmi-52 units two asmi-52 units must be configured for this application. Both units have the same configuration parameters, except for the host ip address and t...

  • Page 104

    Asmi-52 installation and operation manual chapter 5 configuring a typical application configuring the asmi-52 units 5-3 set the co asmi-52 unit clock to internal. Set the cpe asmi-52 unit clock to receive. 3. Select save to save the changes. To set the device host ip address: 1. Display the host ip ...

  • Page 105

    Chapter 5 configuring a typical application asmi-52 installation and operation manual 5-4 configuring the asmi-52 units 2. From the framed mode menu, select unframed to choose the unframed operation. The e1 local port menu appears. 3. Save the changes. After performing these configuration procedures...

  • Page 106

    Asmi-52 installation and operation manual chapter 5 configuring a typical application configuring the asmi-52 units 5-5 asmi-52 dte local port configuration > 1. Llb from dte : (enable/disable) 2. Rlb from dte : (enable/disable) 3. Data rate : (1984 kbps) 4. Save > esc-prev. Menu; !-main menu; &-exi...

  • Page 107

    Chapter 5 configuring a typical application asmi-52 installation and operation manual 5-6 configuring the asmi-52 units.

  • Page 108: Chapter 6

    Monitoring performance 6-1 chapter 6 troubleshooting and diagnostics this chapter describes the asmi-52 diagnostic functions, which include: • status indications, alarms, power-up self-test • statistics collection • bit error rate test (bert) • diagnostic tests (loopbacks and leds test). 6.1 monitor...

  • Page 109

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-2 monitoring performance 2. From the physical port statistics menu, select shdsl port performances to display the unit’s sdhsl statistics. The sdhslport performances menu appears (see figure 6-2 ). Asmi-52 shdsl po...

  • Page 110

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics monitoring performance 6-3 asmi-52 shdsl current day performances local a local b remote a remote b port number (1) (1) (1) (1) 24 hour es (1) (1) (1) (1) 24 hour uas (1401) (1401) (1401) (1401) 24 hour ses (0) (0) (...

  • Page 111

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-4 monitoring performance asmi-52 shdsl all intervals local/remote performances ... Line a line b int crc losws es ses uas crc losws es ses uas esc-prev. Menu; !-main menu; &-exit; ?-help; @-scroll figure 6-5. Shdsl...

  • Page 112

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics monitoring performance 6-5 • for details on enabling the crc-4 function, refer to chapter 4 . • for the details on configuring t1 framing, refer to configuring t1 interface in chapter 4. Displaying the current e1/t1 ...

  • Page 113

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-6 monitoring performance asmi-52 e1/t1 current day performance local remote port number (1) no statistics collection esc-prev. Menu; !-main menu; &-exit; @-scroll figure 6-9. E1/t1 current day performances screen t...

  • Page 114

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics monitoring performance 6-7 table 6-2. . E1 statistics parameters (cont.) display description range current dm number of degraded minutes in which the ber exceeded 1×10 -6 . This value is updated every minute for 15-m...

  • Page 115

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-8 handling alarms clearing the e1/t1 statistics to clear e1/t1 statistics: • from the e1 port performances menu (see figure 6-2 ), select e1/t1 clear local performances or e1/t1 clear remote performances (main menu...

  • Page 116

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics handling alarms 6-9 displaying all alarms asmi-52 allows you to display all alarms, irrespective of their origin (system or port). To display all alarms: 1. From the main menu, select monitoring. The monitoring menu ...

  • Page 117

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-10 handling alarms asmi-52 system monitoring 1. System status 2. System log file 3. System clear log file ... > esc-prev.Menu; !-main menu; &-exit; @-scroll figure 6-13. System monitoring menu working with the syst...

  • Page 118

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics handling alarms 6-11 asmi-52 physical port status port number (1) 1. Port status 2. Line mask (no_mask) 3. Port log file 4. Port clear log file > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 6-14. Physical po...

  • Page 119

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-12 handling alarms table 6-3. Asmi-52 alarms and warnings (cont.) number terminal message port description severity 12 snr margin over line b shdsl line b signal-to-noise margin has exceeded the alarm threshold (4-...

  • Page 120

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics handling alarms 6-13 table 6-3. Asmi-52 alarms and warnings (cont.) number terminal message port description severity 32 e1 excesive err ratio t1 excesive err ratio dte the bit error rate of the link exceeds 10 -3 ma...

  • Page 121

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-14 handling alarms table 6-3. Asmi-52 alarms and warnings (cont.) number terminal message port description severity 45 loop attn. Over customer side shdsl loop attenuation at the customer side of the repeater has e...

  • Page 122

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics troubleshooting 6-15 table 6-4. Asmi-52 events terminal message description crc event line a crc errors are detected on line a crc event line b crc errors are detected on line b sw download fail software download fai...

  • Page 123

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-16 testing asmi-52 asmi 52 port log file source name severity status time 1. Local mngmnt is down major on 0:00:00 2. Local e1 sync loss line a major on 0:00:00 3. Local e1 signal loss major on 0:00:00 4. Local syn...

  • Page 124

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics testing asmi-52 6-17 bit error rate test (bert) it is possible to generate bert+rlb or bert (from both co and cpe) in multiplexer and e1 and dte serial single units. The bert, rlb + bert can be set only if there is a...

  • Page 125

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-18 testing asmi-52 asmi-52 bert 1. Bert (on/off) 2. Bert + rlb (on/off) 3. Bert pattern > 4. Save bert parameters > esc-prev. Menu ; !–main menu ; &–exit terminal figure 6-16. Bert menu 3. From the bert menu, selec...

  • Page 126

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics testing asmi-52 6-19 asmi-52 bert results local remote run time (seconds) 2000 sync loss state sync loss sync run time (seconds) 2000 sync loss counter 2000 total bits 3000 error bits 50 ber 5.5e-4 > esc-prev. Menu; ...

  • Page 127

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-20 testing asmi-52 loopback in multiplexer units figure 6-20 is an illustration of how loopback works in the local asmi-52. Figure 6-20. Loopback with multiplexer units running the local loopback the local loopback...

  • Page 128

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics testing asmi-52 6-21 local dte data local asmi-52 data clock clock line interface glue logic transmit receive figure 6-21. Local loopback to run the local loopback: 1. From the main menu, select diagnostics. The diag...

  • Page 129

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-22 testing asmi-52 asmi-52 local test or remote test llb from dte: off rlb from dte: off 1. Bert > 2. Llb (on) 3. Loop timeout (min)(0-4095) ...(5) 4. Leds test 5. Clear all 6. Save > esc-previous menu ; !–main men...

  • Page 130

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics testing asmi-52 6-23 to activate the remote loopback: 1. From the diagnostics menu (see figure 6-22 ), select local test to run the rlb on the local asmi-52, or select remote test to run the rlb on the remote asmi-52...

  • Page 131

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-24 testing asmi-52 data local asmi-52 repeater 1 repeater 2 data clock clock line interface customer interface customer interface network interface network interface transmit receive local dte glue logic figure 6-2...

  • Page 132

    Asmi-52 installation and operation manual chapter 6 troubleshooting and diagnostics technical support 6-25 6.6 frequently asked questions what if the link indicator (10baset version) does not light immediately after asmi-52 is turned on? The ir-ip interface module does not receive power from the asm...

  • Page 133

    Chapter 6 troubleshooting and diagnostics asmi-52 installation and operation manual 6-26 technical support.

  • Page 134: Appendix A

    Dte interface connectors a-1 appendix a interface connector specifications a.1 dte interface connectors v.35, x.21 and rs-530 interface connectors the v.35 interface of the asmi-52 modem terminates in a 34-pin female connector. The x.21 interface terminates in a 15-pin, d-type female connector. The ...

  • Page 135

    Appendix a interface connector specifications asmi-52 installation and operation manual a-2 dte interface connectors table a-1. V.35, x.21 and rs-530 connector pinouts (cont.) v.35 rs-530 x.21 description 34-pin db-25 db-15 signal function pin circuit pin circuit pin circuit (function) data set read...

  • Page 136

    Asmi-52 installation and operation manual appendix a interface connector specifications dte interface connectors a-3 e1 and t1 interface connector the balanced e1 and t1 interfaces terminate in rj-45 connector. Table a-2 lists the balanced connector pin assignment. Table a-2. E1/t1 connector pinout ...

  • Page 137

    Appendix a interface connector specifications asmi-52 installation and operation manual a-4 control connector a.2 control connector the control terminal interface terminates in a v.24/rs-232 9-pin d-type female connector that can be configured as dce or dte (see the selecting the control port interf...

  • Page 138

    Asmi-52 installation and operation manual appendix a interface connector specifications alarm relay connector a-5 table a-6. Cross cable pinout db-9 pin db-9 pin 2 3 3 2 4 6 5 5 6 4 7 8 8 7 a.3 alarm relay connector the asmi-52 alarm relay terminates in a 6-pin female connector, designated alarm. Fi...

  • Page 139

    Appendix a interface connector specifications asmi-52 installation and operation manual a-6 alarm relay connector.

  • Page 140: Appendix B

    Introduction b-1 appendix b ir-ip interface module b.1 introduction overview ir-ip is a high-performance, miniature ip router based on rad's unique ip router chip, the chip router. Ir-ip has a 10baset (utp) interface and complies with ieee 802.3. The router interface operates in either half-duplex o...

  • Page 141

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-2 technical specifications application figure b-1 shows a typical application of the asmi-52 unit equipped with the ir-ip interface module. Figure b-1. Typical application of the asmi-52 unit with ir-ip b.2 technical speci...

  • Page 142

    Asmi-52 installation and operation manual appendix b ir-ip interface module physical description b-3 b.3 physical description figure b-2 shows the rear panels of asmi-52 with the ir-ip interface module. Control alarm line b line a 1 4 2 5 act link act link err setup 1 2 3 4 ir-ip e1/t1 shdsl tx rx 1...

  • Page 143

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-4 physical description ir-ip leds ir-ip contains three leds, which indicate the module activity. Table b-3 explains the functions of the ir-ip interface indicators. Table b-3. Ir-ip interface indicators led name function c...

  • Page 144

    Asmi-52 installation and operation manual appendix b ir-ip interface module ir-ip management subsystem b-5 b.4 ir-ip management subsystem the ir-ip interface module management subsystem supports the following functions: • preliminary configuration • configuration of management access parameters • ad...

  • Page 145

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-6 performing preliminary configuration after configuring ir-ip, it starts normal operation and routes the traffic in accordance with the user-selected configuration parameters. To change the parameters of an already-config...

  • Page 146

    Asmi-52 installation and operation manual appendix b ir-ip interface module performing preliminary configuration b-7 connecting the telnet host before starting the management and configuration activities, it is necessary to establish ip communication between your telnet host and the ir-ip interface ...

  • Page 147

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-8 performing preliminary configuration to use the ip learning mechanism, you do not need to know the current address of ir-ip lan interface, but only the prescribed ip address. The ip address is actually retrieved from the...

  • Page 148

    Asmi-52 installation and operation manual appendix b ir-ip interface module ir-ip management utility b-9 at this stage, the communication with ir-ip router is lost, because its ip address has been changed. Therefore, you must reconfigure the destination ip address of the telnet host. If you wish, yo...

  • Page 149

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-10 ir-ip management utility starting a management utility the management utility is started automatically when telnet communication is established. If password protection is enabled (see the defining management access sect...

  • Page 150

    Asmi-52 installation and operation manual appendix b ir-ip interface module quick setup guide b-11 b.7 quick setup guide the quick setup menu is used to select the main parameters’ values that must be defined before you start using ir-ip. Use the advanced setup menu (see the advanced setup section b...

  • Page 151

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-12 quick setup guide wan ip address – used to enter the ip address for the ir-ip wan interface, i.E., the ip address to be used by ip hosts on the wan to reach this ir-ip interface module. If the wan ip address field remai...

  • Page 152

    Asmi-52 installation and operation manual appendix b ir-ip interface module quick setup guide b-13 asmi-52 with ir-ip lan ip address: 192.168.1.2 mask: 255.255.255.248 dhcp server ip network figure b-7. Selecting the ip subnet mask leaving the dhcp server ip address field blank disables the dhcp rel...

  • Page 153

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-14 defining management access b.8 defining management access the management access menu is used to enable the use of passwords to protect the access to ir-ip management utility, and control the inactivity time-out interval...

  • Page 154

    Asmi-52 installation and operation manual appendix b ir-ip interface module advanced setup b-15 b.9 advanced setup the advanced setup menu is used to select the desired group of ir-ip configuration parameters. The parameters accessed through advanced setup menu supplement the parameters available on...

  • Page 155

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-16 advanced setup ir_ip s/w ver. 1.21 (date) quick setup management access advanced setup ................................................................. Device identification interface parameters =======================...

  • Page 156

    Asmi-52 installation and operation manual appendix b ir-ip interface module advanced setup b-17 defining the wan protocol parameters frame relay protocol the frame relay protocol parameters menu is used to configure the parameters frame relay wan for protocol (the wan protocol is selected by means o...

  • Page 157

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-18 advanced setup ppp protocol menu the ppp protocol parameters menu is used to configure the parameters ppp wan for protocol (the wan protocol is selected by means of the (the wan protocol is selected by means of the quic...

  • Page 158

    Asmi-52 installation and operation manual appendix b ir-ip interface module advanced setup b-19 defining the multicast parameters the multicast ip menu is used to specify the ip multicast frame forwarding parameters, and to access the static multicast groups’ table. To define the multicast parameter...

  • Page 159

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-20 using the device control menu to access the static groups menu: 1. From the multicast ip menu, type 2. The following screen appears: ir_ip s/w ver. 1.21 (date) static multicast groups table -----------------------------...

  • Page 160

    Asmi-52 installation and operation manual appendix b ir-ip interface module using the device control menu b-21 downloading new software ir-ip operates as a tftp client, and therefore it is possible to update its software by downloading new software from another computer that operates as a tftp serve...

  • Page 161

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-22 using the device control menu erasing configuration selecting erase configuration allows you to reset all the configuration parameters to their default values. • do this only if you need to reconfigure the module anew (...

  • Page 162

    Asmi-52 installation and operation manual appendix b ir-ip interface module viewing ir-ip configuration data b-23 this operation restarts the ir-ip lan controller. To continue your telnet session, press any key within 15 seconds following the confirmation of the reset operation. Reset wan to reset t...

  • Page 163

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-24 viewing ir-ip configuration data ir_ip s/w ver. 1.21 (date) view configuration ------------------ boot version: 1.06 18.03.1999 device name: ip router card system location: the location of this device contact person: na...

  • Page 164

    Asmi-52 installation and operation manual appendix b ir-ip interface module viewing ir-ip configuration data b-25 ir_ip s/w ver. 1.21 (date) multicast groups table ---------------------- group ip address status group ip address status press any key for exit figure b-21. Multicast groups table screen...

  • Page 165

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-26 using diagnostic tools (ping terminal) ir_ip s/w ver. 1.21 (date) system statistics ----------------- counter name val counter name val wan in octets 83504 wan alignment errors 0 wan out octets 1950 wan aborted frames 0...

  • Page 166

    Asmi-52 installation and operation manual appendix b ir-ip interface module using diagnostic tools (ping terminal) b-27 using the ping function the ping option is used to confirm ip connectivity by pinging other ip hosts. Connectivity is confirmed by receiving a reply from the remote (pinged) ip hos...

  • Page 167

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-28 erasing ir-ip software b.13 erasing user’s configuration the user-defined configuration parameters are stored in the ip router card flash memory. After the user-defined configuration parameters are erased, the ip router...

  • Page 168

    Asmi-52 installation and operation manual appendix b ir-ip interface module erasing ir-ip software b-29 erasing application software to erase the application software: 1. Turn asmi-52 off. 2. Set all the four sections of ir-ip dip switch to on. 3. Turn asmi-52 on and monitor the err and link indicat...

  • Page 169

    Appendix b ir-ip interface module asmi-52 installation and operation manual b-30 erasing ir-ip software 5. Run a standard tftp client application on the telnet host, and download the appropriate software file. If the download is successful, ir-ip starts using the new software. If the downloading fai...

  • Page 170: Appendix C

    Technical specifications c-1 appendix c easy config device this appendix describes the easy config hand-held device intended for asmi-52 configuration via the v.24 (rs-232) control port, eliminating the need for an ascii terminal. Using the easy config, the local user can perform the same configurat...

  • Page 171

    Appendix c easy config device asmi-52 installation and operation manual c-2 installation c.3 installation package contents the easy config package contains the following items: • easy config device • ac/dc power adapter • interface cable with db-9 male and female connectors. Connecting the interface...

  • Page 172

    Asmi-52 installation and operation manual appendix c easy config device operation c-3 c.4 operation turning the easy config on to turn the easy config on: • set the top panel bat switch to off if the easy config receives power from the external ac/dc adapter. Or • set the top panel bat switch to on ...

  • Page 173

    Appendix c easy config device asmi-52 installation and operation manual c-4 operation scrolling the asmi-52 menus the easy config enables the user to scroll through the asmi-52 menus. The menu structure is circular – the menu screens are displayed on the lcd one after another in cyclic order. To scr...

  • Page 174

    Asmi-52 installation and operation manual appendix c easy config device operation c-5 5. Repeat steps 3–4 to complete the selection. Use the s character as a space use the esc button to delete the last entered character. 6. Press the enter button to accept selected values. 7. If an invalid value is ...

  • Page 175

    Appendix c easy config device asmi-52 installation and operation manual c-6 operation 7. Press the x button to select the value. The s character designating space is stored in the bottom row: s 111s 8. Repeat steps 4–7 to enter the remaining values. Mind the spaces between the ip address portions. T...

  • Page 176: Index

    I-1 index —a— ac power, 2-4 adapter cable cbl-rj-45/2bnc/e1, 1-5 aging timeout, 4-9 alarm reporting, 1-10 alarm relay, 1-14 connecting, 2-4 alarms clearing, 6-10 displaying, 6-9 index of, 6-11 masking, 6-11 applications, 1-2, b-2 asmi-52 menu map, 3-11 autoconfiguration tftp or xmodem, 4-44 autonego...

  • Page 177

    Index asmi-52a installation and operation manual i-2 default gateway, 4-3 default ip communication parameters, b-6 default settings, 3-4 control port, 3-5 e1/e1+ethernet/e1+serial dte interface, 3-6 lan configuration, 3-4 resetting, 4-47 serial dte interface, 3-6 shdsl interface, 3-5 system, 3-4 det...

  • Page 178

    Asmi-52a installation and operation manual index i-3 preliminary configuration, b-6 quick setup menu, b-11 reset, b-22 reset lan, b-22 reset to default values, b-22 reset wan, b-23 resetting, b-22 static groups, b-19 statistics, b-25 technical specifications, b-2 —l— lan aging timeout, 4-9 autonegot...

  • Page 179

    Index asmi-52a installation and operation manual i-4 —o— operating temperature, 2-2 —p— package contents, 2-2 password, 4-40 changing, 4-20 default, 4-40 performance monitoring, 1-14 physical description, 1-10 plastic enclosure, 1-15 pinout rj-45, b-3 point-to-point protocol (ppp), b-1 port alarms m...

  • Page 180

    Asmi-52a installation and operation manual index i-5 e1/t1, 4-31 timing, 1-8, 1-14 troubleshooting, 6-15 tsa, 4-34 turning off, 3-15 —u— unit enclosure, 1-2 unit identical settings, 4-34 user name, 4-40 —v— versions, 1-1 virtual connection, 4-39 —x— xmodem installing new software, 4-44.

  • Page 181

    Index asmi-52a installation and operation manual i-6.

  • Page 182: Customer Response Form

    24 raoul wallenberg st., tel aviv 69719, israel tel: +972-3-6458181, fax: +972-3-6483331, +972-3-6498250 e-mail: , web site: customer response form rad data communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us a...

  • Page 184: Error Report

    Error report type of error(s) ❒ incompatibility with product or problem(s): ❒ difficulty in understanding text ❒ regulatory information (safety, compliance, warnings, etc.) ❒ difficulty in finding needed information ❒ missing information ❒ illogical flow of information ❒ style (spelling, grammar, re...

  • Page 187

    Publication no. 148-200-10/05 www.Rad.Com international headquarters: 24 raoul wallenberg street, tel aviv 69719, israel, tel: 972-3-6458181 fax: 972-3-6498250, 972-3-6474436, email: market@rad.Com north america headquarters: 900 corporate drive, mahwah, n.J. 07430, tel: (201) 529-1100 toll free: 1-...