    Owner & operator instruction manual for service contact: german knife inc. 1-800-500-3519 www.Turboairinc.Com model no. Www.Turboairinc.Com important safety notice this manual has been prepared for personnel qualified to install gas equipment, who should perform the initial field start-up and adjust...

  • Page 2

    2 table of contents installation & operation instruction general / rating plate clearance / caution / high shelf assembly leveling / air supply & ventilation gas connection / manual shut-off valve pressure regulator 60” range requires two gas connections rigid connections flexible couplings initial ...

  • Page 3

    3 installation & operation instruction general (1) a manual gas shut-off valve must be installed in the gas supply (service) line ahead of the appliance and gas pressure regulator in the gas stream for safety and ease of future service. (2) the gas pressure regulator supplied must be installed on th...

  • Page 4

    4 installation & operation instruction clearance combustible construction back sides floor 8” 12” non-combustible 0 0 6” non-combustible construction the appliance area must be kept free and clear of all combustible. This unit is design-certified for the following installation only: the clearances f...

  • Page 5

    5 installation & operation instruction leveling (ranges equipped with ovens) a carpenter's spirit level should be placed on the oven's center baking rack and/or across the range top and the unit leveled both front to back and side to side. If it is not leveled, cakes, casseroles, and any other liqui...

  • Page 6

    6 installation & operation instruction gas connection note : the gas supply(service) line must be the same size or greater than the inlet line of the appliance. Radiance ranges and ovens use a 3/4" npt inlet. Sealant on all pipe joint must be resistive to lp gas. Manual shut-off valve this installer...

  • Page 7

    7 installation & operation instruction 60” range requires two gas connections the gas inlet line size of this unit is ¾” npt. For proper installation, the gas service supply line must be the same size or greater than the inlet line size of the unit. Each gas connection or inlet should have an indivi...

  • Page 8

    8 installation & operation instruction rigid connections double check any installer supplied intake pipes visually and/or blow them out with compressed air to clear any dirt particles, threading chips , or other foreign matter before installing a service line. Those particles will clog orifices when...

  • Page 9

    9 initial pilot lighting a. Top burners / raised griddle-broiler all radiance appliances are adjusted and tested before leaving the factory, effectively matching them to sea level conditions. Adjustments and calibrations to assure proper operation may be necessary on installation to meet local condi...

  • Page 10

    10 initial pilot lighting d. Standard oven pilot gas is tapped from the main burner manifold pipe, routed through tubing to a pilot safety valve, and then to the pilot burner. Gas flow is controlled by the safety valve. Oven pilot lighting or relighting is to be completed in the following sequence: ...

  • Page 11

    11 final preparation to check for leaks (1) remove the kick plate (see#2 above.) (2) check pilot tubing and burner tubing for leaks where they enter the gas valve with a soapy water solution. (3) light the pilot as described above. (4) check the connection of the pilot tubing leaving the gas valve w...

  • Page 12

    12 cleaning and maintenance any piece of equipment works better and lasts longer when maintained properly. Cooking equipment is no exception. Your radiance range and oven must be kept clean throughout the day and thoroughly cleaned at the end of the day. Open burners daily 1. Lift all the open grate...

  • Page 13

    13 cleaning and maintenance periodic cleaning check the ventilation system periodically to see that nothing has fallen down into the stub back, high riser or high shelf exhaust vents. Lubricate the pivot pins of oven door hinge where the right and left lever arms connect to the door. Use a multi-pur...

  • Page 14: Limited Warranty

    Limited warranty warranty claim: products under warranty: what is not covered by this warranty: one year warranty: radiance medium duty microwaves- er/mr series (tmw-1100er, tmw-1100mr) radiance ranges & countertop cooking series (all tar-, targ-, tahp-, tarb-, tamg-, tatg-, tasp-, tawr-) radi...