MODE SETUP
NOTE - SWITCH 4 MUST BE IN THE ON/UP POSITION FOR UNIT TO
OPERATE. AFTER CONFIGURATION OF UNIT POWER MUST BE RESET.
THIS CAN BE DONE BY REMOVING POWER TO UNIT OR TOGGLE SWITCH 4
DOWN THEN UP.
SETTINGS-
AUTO-NEGOTIATION - SW 1, SW 2, SW 3 DOWN/OFF
10M HALF DUPLEX - SW 1 UP/ON, SW 2, SW 3 DOWN/OFF
10M FULL DUPLEX - SW 1 UP/ON, SW 2 DOWN/OFF, SW 3 UP/ON
100M HALF DUPLEX - SW 1 UP/ON, SW 2 UP/ON, SW 3 DOWN/OFF
100M FULL DUPLEX - SW 1 UP/ON, SW 2 UP/ON, SW 3 UP/ON
TROUBLESHOOTING
POWER LED NOT LIT - CHECK POWER SUPPLY CABLE TO MAIN POWER
SUPPLY. CHECK AC INPUT SOURCE. CHECK SW 4 – MUST BE UP/ON
POSITION.
LINK FX LED NOT LIT – CHECK LIGHT LEVEL IN AND OUT OF UNIT. REFER
TO THE SPEC. LABEL FOR PROPER LEVEL.
TP LED NOT LIT - CHECK SETTING FOR STRAIGHT / X-OVER CABLE. RESET
POWER.
RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04