Radiant RBS 24 Installation And Maintenance Manual

Other manuals for RBS 24: Instruction manual
Manual is about: Wall mounted storage combi boiler room sealed chamber

Summary of RBS 24

  • Page 1

    Ce 0694 tg05a001.B0305 technical specification radiant bruciatori s.P.A. Montelabbate (pu) italy english installation, and maintenance manual for gas fired, wall-hung boilers model rbs 24 type c room sealed sedbuk band d.

  • Page 3

    Index installation instructions and warnings page 1 technical data page 4 overall dimensions - exhaust flue system page 5 general installation requirements page 6 boiler installation page 8 electrical connections page 10 boiler control panel page 11 starting up the boiler for the first time page 11 ...

  • Page 4

    Installation manual heat tecnology since 1959 thank you for choosing radiant declaration for purposes of art. 7 of law 46 of 5 april 1990. Radiant bruciatori s.P.A. Hereby declares that all of its products are constructed to industry standards as required by the article in question and by article 5 ...

  • Page 5

    Installation manual installation instructions - warnings this installation, use, and maintenance manual is an essential and integral part of the product, and must always be kept near the device. The warnings contained in this section are addressed both to the user and to installation and maintenance...

  • Page 6

    Installation manual systems with thermostats a by-pass must be installed in heating systems with radiators thermostats. As required by current norms, these devices must be installed by qualified personnel only, who must respect norms uni-cig 7129 and 7131 and revisions, fire department regulations, ...

  • Page 7

    Installation manual technical data type c unit type c devices are devices in which the combustion circuit (air intake, combustion chamber, exchanger, combustion exhaust) is sealed off from the place where they are installed. Model rbs 24 ce certification no. 0694bl3037 flue category (uni10642) c 12 ...

  • Page 8

    Installation manual overall dimensions - exhaust flue system 115 320 320 115 11 a f g r c 70 49 78 80 102 31 72 3 80 730 170 73 0 11 31 102 80 78 49 70 a f g r c 72 3 10 20 370 20 313 48.5 48.5 100 60 410 127 10 48.5 48.5 313 20 370 20 80 125 80 18 0 165 100 60 46 170 type c wall-mounted boilers sea...

  • Page 9

    Installation manual general installation requirements gas safety it is the law that all gas appliances are installed by a corgi registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed below. Failure to install appliances correctly could...

  • Page 10

    Installation manual flue position important: the flue system shall be installed in accordance with the recommendations contained in bs 5440:1. The boiler must be installed so that the terminal is exposed to the external air. It is important that the position of the terminal allows free passage of ai...

  • Page 11

    Installation manual minimum distances for fixing to wall minimum distance mm. 45 0 60 410 60 s c a f g r to allow access in the boiler for maintenance operations, the minimum distances shown below must be respected (fig. 1): to facilitate installation, the boiler is supplied with a template for adva...

  • Page 12

    Installation manual gas connections the gas supply must be connected up by qualified person. The following standards must be complied with: unicig 7131/72 and unicig 7129/92 (of 21/04/93) before installing the boiler, make sure of the following: • the pipeline must be of an adequate section and leng...

  • Page 13

    Installation manual electrical connections for qualified personell only: the boiler works with 230 v 50 hz ac current and has maximum input of 150 w. Connection to the electrical mains must be performed with a device having an omnipolar opening of at least 3 mm. Make sure the live and neutral connec...

  • Page 14

    Installation manual control panel controls (fig. 1) 1. On / off power button . 2. Heating temperature adjustment knob. 3. Domestic hot water adjustment knob. 4. Stable light: power on flashing light: flame on. 5. Stable light: 40°c temperature flashing light: water d light off: w eficiency ater pres...

  • Page 15

    Installation manual air vent valve cap circulating pump rs air vent valve pump cap starting up the boiler (see fig.1 pag. 11) • turn on the gas cock situated under the boiler grill; • set the on/off button (1) to on position ; • use knob 2 and 3. • to set the heating only mode, turn knob 3 counter c...

  • Page 16

    Installation manual sm 30001 printed circuit board - technical specification new generation printed circuit board with easy settings of boiler parameters. Special features: main functions / features chimney-sweeper function (15 minutes) pump over-run function (2 minutes) pump inactivity protection s...

  • Page 17

    Installation manual functions setting m10 m9 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 natural gas g20 l.P.G. G30/g31 functions setting sm 30001 printed circuit board minicode ® - sm 30001 cod. 76666la functions setting l.P.G. Dual circuit exchanger type h f d e g 8 6 4 5 7 f e d h g 7 g h f e d 7 8 6 5 4...

  • Page 18

    Installation manual 8 9 10 11 12 13 fig. 2 5 6 7 fig. 1 control panel gas valve nordgas nv0111122901 1 2 3 4 controls (fig. 1-2) 1. “maxr” maximum heating potentiometer 2. “min” minimum gas potentiometer 3. “rla” starting step potentiometer 4. “spaz” chimney-sweeper function 5. Gas pressure point - ...

  • Page 19

    Installation manual maximum gas pressure setting • unscrew 5 gas pressure point screw (fig. 1,pag .15) on the gas valve and insert a manometer; • turn heating and domestic hot water setting knobs to the maximum and remove the 2 knob by extracting them with a pliers: • use a Ø2.5 ÷ 3 mm cross-type sc...

  • Page 20

    Installation manual conversion of gas type 5 10 8 6 7 9 5 11 7 6 8 3 4 1 2 conversion of the boiler from natural gas to lpg and viceversa must be performed by qualified personnel only. Conversion is performed as follows: a. Turn off the main power switch; b. Close the gas cock; c. Substitute the jet...

  • Page 21

    Installation manual main components key 1. Heat exchanger 2. Circulation pump with air vent 3. Electronic gas valve vk4105 4. Draining tap 5. Expansion vessel 6. Heating circuit 3 bar pressure relief valve 7. Multigas burner 8. Heating sensor 9. Water pressure switch 10. Electronic flowswitch 11. Fl...

  • Page 22

    Installation manual electrical connection vg tr - transformen - gas valve - line l key - neutral n c sr mf ig ss pa pac ta ts - safety thermostat - room thermostat - heating sensor - circulation pump - air pressure switch - d.H. Water sensor - electronic flowswitch - water pressure switch - main swi...

  • Page 23

    Installation manual maintenance b c a to keep the boiler in efficient and safe operating condition, we recommend you perform the following checks at least once a year: • check all seals on the gas side and replace gaskets to restore perfect seal as required. Check all • seals on the water side and r...

  • Page 24

    Radiant bruciatori s.P.A. Via pantanelli, 164/166 - 61025 loc. Montelabbate (pu) tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • internet: http://www.Radiant.It uk – radiant helpline – 01329.828555 all descriptions and illustrations contained in this leaflet have been carefull...