Radiant RBS 24 Installation And Maintenance Manual - page 23
Installation Manual
MAINTENANCE
B
C
A
To keep the boiler in efficient and safe operating condition, we recommend you perform
the following checks at least once a year:
• Check all seals on the gas side and replace gaskets to restore perfect seal as required.
Check all
•
seals on the water side and replace gaskets to restore perfect seal as
•
eck combustion and the combustion chamber; dismantle and clean the
•
nger and clean it if necessary.
nt gas safety device (flame
•
limit,
•
vice
ressures and the modulation.
in the instruction
required.
Visually ch
chamber if necessary.
Check the primary excha
• Check functioning of gas safety systems: Insufficie
detection sensor for electronic ignition boilers) thermocouple for pilot light boilers.
Check functioning of heating safety systems: safety thermostat for temperature
safety sensor for pressure limit.
Check the exhaust flue safety de
• Check the max. and min. modulation p
Fig. 1
• Check that the electrical connection conforms to the description
manual for the boiler.
• Check the domestic hot water flow rate and temperature.
UNPACKING
A. Set the packed boiler (fig. 1) down on the floor making sure that the arrow is pointing upwards and remove the sticking tape. Open the 4
flaps outwards.
B. Turn the boiler 180° supporting it by hand.
C. Lift the boiler with the packing pieces positioning it vertically in order not to damage the lower corners of the casing and remove the
packing pieces. Lift the boiler by holding it at the back and proceed with installation.
N.B. It is recommended that the boiler be unpacked before installation. The manufacturer cannot be held responsible for any damage
caused to the boiler due to incorrect handling of the boiler.
IMPORTANT!
The packing materials (cardboard) are recyclable.
IMPORTANT!
The inner packing materials (plastic bags, polystyrene foam, nails etc.) are potentially dangerous and must not be left within reach of small
children.
SPARE PARTS SHORT LIST
CODE DESCRIPTION RBS
24
21038LA
GAS BURNER 12 R. 1,30 NATURAL GAS 401.1276.02
√
21039LA
GAS BURNER 12 R. 0.77 L.P.G.
√
24049LA
CIRCULATING PUMP SHUL CLF6 15/6 W/ AIR VENT
√
24029LA
CIRCULATING PUMP MOTOR SHUL CLF6 15/6
√
35007LA
IGNITION ELECTRODE x ELECTRONIC E.0774527
√
35009LA
IONISATION ELECTRODE E.0774929
√
36071LA
ELECTRONIC GAS VALVE NV0111122901
√
76666LA
EXHAUST FAN 230V ES30-98 GR
√
58021LA
MAIN HEAT EXCHANGER
√
59001LA
AIR PRESSURE SWITCH CE C6065AH1095 CE
√
59015LA
WATER PRESSURE SWITCH 1/8’’
√
73507LA
HEATING 1/8’’ SENSOR S011001
√
76666LA
PRINTED CIRCUIT BOARD SM 30001
√
86014LA
WATER PRESSURE GAUGE
√
86027LA
SAFETY THERMOSTAT 90°C WATER
√
88018LA TRANSFORMER
√
95014LA
LT.10 EXPANSELL VESSEL
√
96007LP ELECTRONIC
FLOWSWITCH
√
96039LA
HEATING CIRCUIT 3 bar PRESSURE RELIEF VALVE
√
COMBI – TG05A039.B0305
20