Radionics D279A Operation And Installation Manual - D279A

Other manuals for D279A: User Manual
Manual is about: Independent Zone Control (I.Z.C.)

Summary of D279A

  • Page 1

    D279a independent zone control (i.Z.C.) operation and installation guide r delayed instant armed 3 2 1 5 6 4 8 9 7 * * fi radionics.

  • Page 2: D279A

    D279a operation & installation guide 46456b page 2 copyright © 2000 radionics d279a.

  • Page 3: D279A

    D279a operation & installation manual copyright © 2000 radionics page 3 46456b d279a contents 1.0 introduction .............................................................................................. 5 1.1 manual organization........................................................................

  • Page 4: D279A

    D279a operation & installation guide 46456b page 4 copyright © 2000 radionics d279a contents figures figure 1: installing the d279a ................................................................................................................................................... 9 figure 2: wiring t...

  • Page 5: D279A

    D279a operation & installation manual copyright © 2000 radionics page 5 46456b d279a introduction 1.0 introduction 1.1 manual organization this manual is divided up into five sections, which are summarized in the table below. Section description 1 introduction 2 overview provides an overview of the ...

  • Page 6: D279A

    D279a operation & installation guide 46456b page 6 copyright © 2000 radionics d279a introduction 1.3.2 tips, notes, cautions and warnings throughout this document helpful tips and notes will be presented concerning the entire application and/or programming the unit. They will be set off as follows: ...

  • Page 7: D279A

    D279a operation & installation manual copyright © 2000 radionics page 7 46456b d279a overview 2.0 overview with a d279a, you can arm and disarm a single zone or point of a radionics control/communicator panel separately from the rest of the system. The independent zone control (izc) features a user-...

  • Page 8: D279A

    D279a operation & installation guide 46456b page 8 copyright © 2000 radionics d279a overview notes:.

  • Page 9: D279A

    D279a operation & installation manual copyright © 2000 radionics page 9 46456b d279a installation 3.0 installation you can mount the d279a directly onto a wall, install it in a flush-mount unit, or attach it to a d55 desk stand (see the special installation instruction sheet that comes with each ite...

  • Page 10: D279A

    D279a operation & installation guide 46456b page 10 copyright © 2000 radionics d279a 2. Connect the d279a to the panel and protective zones or points as shown in figure 2. • install a 1 kw eol beyond the last sensor of both the delayed and instant loops to provide a reference for supervision. • no t...

  • Page 11: D279A

    D279a operation & installation manual copyright © 2000 radionics page 11 46456b d279a operation 4.0 operation 4.1 loop inputs the d279a branches one zone or point of the panel into two separate loops: one delayed and one instant. Sensors can be wired to these loops in series (normally closed), or in...

  • Page 12: D279A

    D279a operation & installation guide 46456b page 12 copyright © 2000 radionics d279a 4.13 buzzer during entry delay, the buzzer sounds steadily until an alarm occurs or the d279a is disarmed. If you press a numbered key while the d279a is disarmed and a loop is faulted, the buzzer indicates that the...

  • Page 13: D279A

    D279a operation & installation manual copyright © 2000 radionics page 13 46456b d279a programming 5.0 programming 5.1 user passcode the d279a independent zone control comes programmed with a standard passcode of 1234 or 2222 (if the 1234 doesn’t work try 2222). Once the unit is installed and power c...

  • Page 14: D279A

    D279a operation & installation guide 46456b page 14 copyright © 2000 radionics d279a 5.2 programming the d8112 panel protective zone the d279a controls arming/disarming and entry/exit delay for the zone input to which it is connected. Independently controlled zones use distinctive zone codes that do...

  • Page 15: D279A

    D279a operation & installation manual copyright © 2000 radionics page 15 46456b d279a programming 5.3 programming the d7112 panel point the d279a controls arming/disarming and entry/exit delay for the point to which it is connected. 5.3.1 supervised independent zone controls (opening and closing rep...

  • Page 16: Programming

    © 2000 radionics, a division of detection systems, inc. 46456b 11/00) ® the radionics logo is a registered trademark of radionics, operation & installation manual d279a po box 80012, salinas, ca 93912-0012 usa page 16 of 16 customer service: (800) 538-5807 if programming the d279a with 9000 series c...